{"product_id":"kraus-naimer-2-string-dc-isolator-kgd40b-td108","title":"Kraus \u0026 Naimer 2 String Solar PV DC Isolator KGD40B TD108\/D-P004 KL11V up to 1000V IP66\/67","description":"\u003ch1 style=\"color: #f87c24;\"\u003eKraus \u0026amp; Naimer 2 String Solar PV DC Isolator KGD40B TD108\/D-P004 KL11V\u003c\/h1\u003e\n\u003cp\u003eOne switch, two strings. The Kraus \u0026amp; Naimer KGD40B TD108\/D-P004 KL11V isolates two independent solar PV strings from a single rotary handle, so a dual MPPT inverter needs one DC isolator on the wall instead of two. That means one enclosure to mount, fewer cable runs and less labour on site.\u003c\/p\u003e\n\u003cp\u003eEach string is switched on two poles and rated to DC-21B under IEC 60947-3, from 50A at 400V up to 30A at 1000V per string. The switch comes fitted in an IP66\/67 enclosure with a UL94 V-0 flame rated housing.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolates two separate PV strings with one rotary handle\u003c\/li\u003e\n\u003cli\u003e2 x 2 pole construction: positive and negative of each string switched\u003c\/li\u003e\n\u003cli\u003eDC-21B ratings per string from 400V 50A to 1000V 30A\u003c\/li\u003e\n\u003cli\u003eIP66\/IP67 rated enclosure for indoor and outdoor installation\u003c\/li\u003e\n\u003cli\u003eUL94 V-0 flame retardant enclosure\u003c\/li\u003e\n\u003cli\u003eBuilt to IEC 60947-3, CE marked\u003c\/li\u003e\n\u003cli\u003eClear OFF and ON positions on the front plate\u003c\/li\u003e\n\u003cli\u003eKnockouts for cable gland entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMost string and hybrid inverters have two MPPT inputs. Fitting a separate DC isolator for each string doubles the hardware, the wall space and the installation time. The KGD40B TD108 handles both strings in one unit while keeping them electrically separate, each with its own positive and negative path through the switch.\u003c\/p\u003e\n\u003cp\u003eBS 7671 requires a means of isolating the DC side of a PV inverter so it can be maintained safely. This switch disconnector provides that isolation for both strings in a single action. The contacts are factory linked to achieve the published ratings, and Kraus \u0026amp; Naimer states the rating data is not valid if the links are removed.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; border:2px solid #f87c24;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color:#f87c24; color:#ffffff;\"\u003e\n\u003cth style=\"padding:8px; text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eKraus \u0026amp; Naimer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eKGD40B TD108\/D-P004 KL11V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eSolar PV DC switch disconnector, 2 string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e2 x 2 pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eUtilisation category\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eDC-21B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eRating per string at 400V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eRating per string at 500V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eRating per string at 660V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eRating per string at 800V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eRating per string at 1000V DC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eIP66 \/ IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eEnclosure flame rating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eUL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eIEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eMarking\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #f87c24; padding:8px;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual MPPT grid tied and hybrid string inverters\u003c\/li\u003e\n\u003cli\u003eResidential rooftop solar PV systems with two strings\u003c\/li\u003e\n\u003cli\u003eCommercial PV arrays with two strings per inverter\u003c\/li\u003e\n\u003cli\u003eReplacing two single string isolators with one unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Kraus \u0026amp; Naimer KGD40B TD108\/D-P004 KL11V 2 string DC switch disconnector, fitted in IP66\/67 enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation and Safety Notes\u003c\/h3\u003e\n\u003cp\u003eSolar panels produce dangerous DC voltage whenever light falls on them, and they cannot be switched off at the source. This switch must be installed by a qualified electrician or MCS certified installer in line with BS 7671.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the string open circuit voltage at the lowest expected temperature and the string current, then confirm both fall within the rating column used.\u003c\/li\u003e\n\u003cli\u003eKeep the factory links in place. Ratings are not valid if the links are removed.\u003c\/li\u003e\n\u003cli\u003eUse correctly sized PV cable, suitable cable glands and correct polarity on each string.\u003c\/li\u003e\n\u003cli\u003eKeep string 1 and string 2 separate. Never cross connect them.\u003c\/li\u003e\n\u003cli\u003eDo not open the enclosure while the strings are connected.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":56147478774051,"sku":"003289","price":187.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/kraus-naimer-kgd40b-td108-2-string-dc-isolator-front.jpg?v=1795595964","url":"https:\/\/voltaconsolar.eu\/ro\/products\/kraus-naimer-2-string-dc-isolator-kgd40b-td108","provider":"VoltaconSolar EU","version":"1.0","type":"link"}