{"product_id":"victron-phoenix-inverter-48-3000-230v-ve-bus","title":"Victron Phoenix Inverter 48\/3000 230V VE.Bus - PIN483020000","description":"\u003ch1 style=\"color: #f87c24;\"\u003ePhoenix Inverter 48\/3000 230V VE.Bus\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Phoenix Inverter 48\/3000 230V VE.Bus is a pure sine wave inverter designed for off-grid and backup power applications. It converts 48V DC battery power to 230V AC at 3000VA continuous output, making it suitable for professional installations where reliable AC power is required from a battery bank. The VE.Bus interface enables multi-unit parallel and three-phase configuration as well as integration with Victron monitoring and control systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous output at 230V AC from a 48V DC battery bank, with pure sine wave output suitable for sensitive loads.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface allows parallel operation with multiple units and three-phase system configuration.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices and the VEConfigure toolset for remote monitoring, configuration and firmware updates.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in PowerControl and PowerAssist functionality when used alongside a Victron Multi or in supported configurations.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protection including over-temperature, overload, short circuit and low battery voltage shutdown.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range with automatic load-dependent fan speed control to reduce noise at partial loads.\u003c\/li\u003e\n  \u003cli\u003eCompact and wall-mountable design with a unit weight of 18.3 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Phoenix 48\/3000 operates on a 48V battery bank, a voltage level commonly chosen for larger off-grid systems because it reduces cable losses and allows more efficient use of battery capacity compared to 12V or 24V systems. At 3000VA, it can support a meaningful range of AC loads including lighting, power tools, refrigeration and computing equipment, depending on the load profile and battery capacity available.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Bus interface is what separates this unit from Victron's simpler inverter range. It allows up to six units to be connected in parallel for increased power output, or configured as a split-phase or three-phase system. This makes the Phoenix 48\/3000 VE.Bus a practical choice for installations that may need to scale, or where three-phase AC output is required. VE.Bus also enables full integration with Victron GX monitoring devices such as the Cerbo GX, giving installers and end users visibility of system performance via the VRM portal.\u003c\/p\u003e\n\n\u003cp\u003ePure sine wave output means the inverter is compatible with all standard AC loads, including motor-driven equipment and electronics with switch-mode power supplies. The inverter's protection features handle common fault conditions automatically, and the load-dependent fan control keeps the unit quieter during light-load operation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN483020000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076023852\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins, lodges and remote buildings requiring 230V AC power from a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle installations where a high-capacity 48V inverter is needed for onboard AC loads.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical equipment in commercial or agricultural premises.\u003c\/li\u003e\n  \u003cli\u003eScalable off-grid systems where parallel or three-phase configuration may be required as load demands grow.\u003c\/li\u003e\n  \u003cli\u003eIntegration into Victron-based energy systems alongside MPPT charge controllers, GX monitoring devices and lithium or lead-acid battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Phoenix Inverter 48\/3000 230V VE.Bus (PIN483020000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter operates at 48V DC and 3000VA output. Installation should be carried out by a qualified electrician or accredited installer with experience in battery-based power systems. DC cabling must be correctly rated for the current involved at 48V, and appropriate DC fusing must be installed between the battery bank and the inverter. For any grid-connected or grid-backup application, compliance with current UK wiring regulations and network operator requirements is the installer's responsibility. VE.Bus configuration requires the Victron VEConfigure software and a suitable interface cable or GX device.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55582728093987,"sku":"PIN483020000","price":3102.0,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/VoltaconSolar_-_PIN483020000_-_Phoenix_Inverter_48-3000_230V_VE.Bus.webp?v=1789121781","url":"https:\/\/voltaconsolar.eu\/products\/victron-phoenix-inverter-48-3000-230v-ve-bus","provider":"VoltaconSolar EU","version":"1.0","type":"link"}