{"product_id":"victron-multiplus-ii-48-8000-110-100-230v","title":"Victron MultiPlus-II 48\/8000\/110-100 230V - PMP482805000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 48\/8000\/110-100 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 48\/8000\/110-100 is a combined inverter and battery charger rated at 8000VA continuous output, designed for demanding off-grid, backup and hybrid solar installations. It accepts a 48V battery bank and delivers 230V AC output, with a 110A battery charger and 100A AC transfer switch built in. Suitable for residential, commercial and industrial applications where high power capacity and reliable grid or generator interaction are required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8000VA continuous inverter output with a 16000W peak surge capacity, suitable for high-load equipment and motor starting.\u003c\/li\u003e\n  \u003cli\u003e110A multi-stage battery charger with adaptive charge algorithm, compatible with lead-acid (AGM, gel, flooded) and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e100A AC transfer switch enables fast changeover between grid, generator and inverter power with minimal interruption.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions allow the unit to limit AC input draw and supplement it with battery power, preventing generator or grid overload.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery monitor tracks state of charge, allowing accurate management without a separate device.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase operation: up to six units can be configured in parallel for increased capacity or in three-phase arrangements.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for integration with GX devices, enabling full system monitoring and control via VRM or Cerbo GX.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay and configurable charge\/discharge parameters via VEConfigure software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/8000\/110-100 is built around a pure sine wave inverter stage that operates from a 48V DC battery bank. At 8000VA, it can handle large residential loads, commercial equipment or multiple circuits simultaneously. The 110A charger is not a simple bulk charger: it uses Victron's adaptive four-stage algorithm (bulk, absorption, float, storage) and can be configured for different battery chemistries and capacities through VEConfigure software.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is a particularly useful feature in generator or limited-grid scenarios. When AC input is available but limited (for example, a small generator or a restricted grid connection), the MultiPlus-II can draw the maximum permitted current from the source and supplement the remainder from the battery bank. This avoids tripping breakers or overloading a generator while still meeting peak load demand. PowerControl performs the complementary function of capping AC input draw to a user-defined limit.\u003c\/p\u003e\n\n\u003cp\u003eThe unit supports parallel and three-phase configurations without additional hardware beyond the units themselves and VE.Bus cabling. Up to six MultiPlus-II units can be paralleled for a maximum of 48kVA in single-phase, or arranged as a balanced three-phase system. This scalability makes it practical for larger off-grid sites, commercial backup systems and microgrid installations where load growth is anticipated.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482805000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8000VA \/ 8000W continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharger Output Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e110A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePeak Surge Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e16000W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eParallel \/ Three-Phase\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (up to 6 units)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e40.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076050568\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and commercial solar installations requiring high continuous power output.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar systems with grid or generator backup, where PowerAssist is used to manage limited AC input capacity.\u003c\/li\u003e\n  \u003cli\u003eThree-phase commercial or industrial backup systems using multiple MultiPlus-II units in a configured array.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle installations where a 48V battery bank and high AC output are required.\u003c\/li\u003e\n  \u003cli\u003eMicrogrid and community energy projects requiring scalable, paralleled inverter capacity.\u003c\/li\u003e\n  \u003cli\u003eCritical load backup for server rooms, medical facilities or communications infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MultiPlus-II 48\/8000\/110-100 230V inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/8000\/110-100 operates at high DC currents from a 48V battery bank and must be installed by a qualified electrician or accredited installer. In the UK, grid-connected or grid-interactive installations must comply with G98 or G99 requirements depending on export capacity and connection type. Configuration via VEConfigure software should be carried out by a competent person familiar with Victron systems. Lithium battery installations require correct charge profile settings and, where applicable, BMS communication to be configured before commissioning. The unit's weight of 40.8 kg means appropriate lifting and mounting provisions are required during installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551543075,"sku":"PMP482805000","price":1204.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-multiplus-ii-488000110-100-230v-pmp482805000-770454.jpg?v=1789114973","url":"https:\/\/voltaconsolar.eu\/products\/victron-multiplus-ii-48-8000-110-100-230v","provider":"VoltaconSolar EU","version":"1.0","type":"link"}