{"product_id":"victron-multiplus-ii-48-3000-35-32-230v","title":"Victron MultiPlus-II 48\/3000\/35-32 230V - PMP482305012","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 48\/3000\/35-32 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 48\/3000\/35-32 is a combined inverter and battery charger designed for 48V battery systems operating at 230V AC. It is suited to off-grid installations, backup power systems, and solar energy storage applications where a reliable, single-unit inverter charger is required. The integrated transfer switch and PowerAssist function make it a practical choice for both standalone and grid-connected setups.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output at 230V AC from a 48V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e35A battery charger built in, with adaptive charge algorithm to suit a range of battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e32A AC input current limit, with PowerAssist to supplement grid or generator supply during peak loads.\u003c\/li\u003e\n  \u003cli\u003eIntegrated transfer switch for automatic changeover between mains\/generator and inverter operation.\u003c\/li\u003e\n  \u003cli\u003eTwo AC outputs: AC-Out-1 remains live during mains failure; AC-Out-2 disconnects when inverting, allowing non-critical loads to be shed.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for system integration, parallel operation, and three-phase configuration.\u003c\/li\u003e\n  \u003cli\u003eProgrammable via VictronConnect and Venus OS (GX devices) for remote monitoring and control.\u003c\/li\u003e\n  \u003cli\u003eSupports PowerControl to prevent overloading a limited shore or generator supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/3000\/35-32 combines a pure sine wave inverter with a multi-stage battery charger in a single unit. The 48V DC input voltage is well suited to larger battery banks where lower current draw reduces cable losses and improves overall system efficiency compared to 12V or 24V alternatives. At 3000VA, the unit can handle most household or light commercial loads, including motor starting currents that would trip a lesser inverter.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is a key practical feature for installations where the available grid or generator supply is limited. When load demand exceeds the incoming AC supply, the MultiPlus-II draws the shortfall from the battery rather than tripping the supply breaker. This allows a smaller generator to be used without risk of overload. PowerControl performs a similar function by capping the AC input draw to a user-defined limit, protecting the supply connection.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Bus interface allows multiple units to be connected in parallel for increased capacity, or configured for split-phase or three-phase output. This makes the MultiPlus-II 48\/3000\/35-32 a scalable platform for larger installations. Integration with Victron GX devices (such as the Cerbo GX) enables full system monitoring via the VRM portal, including battery state of charge, AC input and output data, and remote firmware updates.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482305012\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e35A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Limit\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransfer Switch\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e18.35 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076058359\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and cabin installations with a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eSolar self-consumption systems with battery storage, integrated via a Victron GX device.\u003c\/li\u003e\n  \u003cli\u003eBackup power for critical loads, with automatic transfer from mains to inverter on supply failure.\u003c\/li\u003e\n  \u003cli\u003eGenerator-assisted systems where PowerAssist allows a smaller genset to cover peak demand.\u003c\/li\u003e\n  \u003cli\u003eScalable multi-unit installations requiring parallel or three-phase configuration via VE.Bus.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications where a 48V DC supply and 230V AC output are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron MultiPlus-II 48\/3000\/35-32 230V inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation should be carried out by a qualified electrician or MCS-accredited installer. The MultiPlus-II connects to both a 48V DC battery bank and a 230V AC supply, and incorrect wiring presents a serious risk of electric shock or fire. For grid-connected applications in the UK, compliance with G98 or G99 requirements must be confirmed with your Distribution Network Operator (DNO) before connection. Battery bank sizing, cable ratings, and fusing must be calculated to suit the 35A charge current and the inverter's peak output demands. Programming via VE.Configure or VictronConnect should be completed before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55582434558243,"sku":"PMP482305012","price":497.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-multiplus-ii-48300035-32-230v-pmp482305010-949442.jpg?v=1789116858","url":"https:\/\/voltaconsolar.eu\/products\/victron-multiplus-ii-48-3000-35-32-230v","provider":"VoltaconSolar EU","version":"1.0","type":"link"}