{"product_id":"victron-multiplus-ii-48-10000-140-100-230v","title":"Victron MultiPlus-II 48\/10000\/140-100 230V - PMP483105000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 48\/10000\/140-100 230V Inverter Charger — PMP483105000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 48\/10000\/140-100 is a 10kVA combined inverter and charger designed for demanding off-grid, backup and hybrid solar installations. Operating on a 48V DC battery bank and delivering 230V AC output, it suits professional installers working on residential, commercial and industrial projects where high continuous power and reliable battery charging are required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e10kVA (10,000VA) continuous inverter output at 230V AC, suitable for high-load applications.\u003c\/li\u003e\n  \u003cli\u003e140A battery charger built in, allowing fast recharge from a generator or grid supply.\u003c\/li\u003e\n  \u003cli\u003e100A AC transfer switch for seamless changeover between grid, generator and inverter output.\u003c\/li\u003e\n  \u003cli\u003e48V DC input compatible with lithium-ion (LiFePO4) and lead-acid battery banks.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions limit generator or grid load while supplementing from battery when demand peaks.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase configurations — up to six units can be combined for higher power or three-phase output.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication port for integration with Victron GX devices, Venus OS and remote monitoring via VRM portal.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay and configurable charge algorithms via VEConfigure software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/10000\/140-100 combines a pure sine wave inverter, a multi-stage battery charger and an AC transfer switch in a single unit. At 10kVA, it is one of the largest single-phase units in the MultiPlus-II range and is well suited to installations where a single inverter-charger must handle substantial continuous loads, such as commercial premises, large off-grid properties or critical backup systems.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist allows the unit to supplement an undersized generator or limited grid connection by drawing additional power from the battery bank when AC demand exceeds the available supply. This means a smaller, more fuel-efficient generator can be used without load-shedding. PowerControl performs the complementary function: it caps the load drawn from the AC input to a user-defined limit, protecting the supply source from overload.\u003c\/p\u003e\n\n\u003cp\u003eMultiple MultiPlus-II units can be configured in parallel to increase total output capacity, or in a split three-phase arrangement for three-phase loads. Configuration and monitoring are handled through VEConfigure and the Victron VRM ecosystem via a compatible GX device. The 140A charger is capable of restoring a large battery bank quickly, which matters in installations where generator run time needs to be minimised.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP483105000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e10,000VA (10kVA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e140A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48.6 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076044956\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge off-grid residential or rural properties with high continuous power demand.\u003c\/li\u003e\n  \u003cli\u003eCommercial and light industrial backup power systems requiring fast transfer and high charger current.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar installations combined with a 48V lithium or lead-acid battery bank and a solar charge controller.\u003c\/li\u003e\n  \u003cli\u003eGenerator-backed systems where PowerAssist reduces fuel consumption and generator sizing requirements.\u003c\/li\u003e\n  \u003cli\u003eThree-phase or high-capacity parallel systems when multiple units are combined.\u003c\/li\u003e\n  \u003cli\u003eCritical infrastructure and telecoms sites requiring reliable 230V AC output from a battery bank.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MultiPlus-II 48\/10000\/140-100 230V inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eAt 48.6 kg, this unit requires two people for safe handling and mounting. Installation must be carried out by a qualified electrician familiar with battery-based inverter systems. For any grid-connected application in the UK, compliance with G98 or G99 (depending on export capacity and DNO requirements) is mandatory and the installer must notify the relevant Distribution Network Operator. High-current DC cabling to the 48V battery bank must be correctly rated and fused in accordance with the manufacturer's wiring guidelines. Battery bank configuration, charge parameters and AC input limits should be set using VEConfigure by a competent person before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632557015331,"sku":"PMP483105000","price":1425.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-multiplus-ii-4810000140-100-230v-pmp483105000-104185.jpg?v=1789114966","url":"https:\/\/voltaconsolar.eu\/products\/victron-multiplus-ii-48-10000-140-100-230v","provider":"VoltaconSolar EU","version":"1.0","type":"link"}