{"product_id":"victron-multiplus-ii-24-5000-120-50-230v","title":"Victron MultiPlus-II 24\/5000\/120-50 230V - PMP242505010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 24\/5000\/120-50 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 24\/5000\/120-50 is a 5000VA inverter charger operating on a 24V DC battery bank and delivering 230V AC output. It is designed for off-grid installations, backup power systems and hybrid solar setups where a high-capacity, reliable inverter charger is required. With a 120A battery charger and 50A transfer switch built in, it handles demanding loads and integrates directly into Victron's wider ecosystem.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5000VA continuous inverter output at 230V AC from a 24V DC battery bank.\u003c\/li\u003e\n  \u003cli\u003e120A built-in battery charger with adaptive charge algorithm for lead-acid and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e50A AC transfer switch for seamless changeover between grid, generator and inverter output.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions allow the unit to limit AC input draw and supplement with battery power during peak demand.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for system integration, remote monitoring and configuration via VictronConnect and Venus OS devices.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase operation when multiple units are combined.\u003c\/li\u003e\n  \u003cli\u003eIntegrated battery temperature and voltage sensing for accurate charge management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 24\/5000\/120-50 combines a pure sine wave inverter, a multi-stage battery charger and an AC transfer switch in a single unit. The 24V input voltage makes it suited to larger battery banks where 24V architecture is preferred, particularly in marine, vehicle and off-grid land installations. At 5000VA, it can handle substantial loads including motors, compressors and combined household circuits.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is a practical feature for installations with a limited AC supply, such as a small generator or a restricted shore power connection. When the AC source approaches its current limit, the MultiPlus-II draws the deficit from the battery bank rather than overloading the source. This allows a smaller generator to support larger loads without tripping breakers or causing voltage collapse.\u003c\/p\u003e\n\n\u003cp\u003eThe unit communicates over VE.Bus, which means it can be configured and monitored using a GX device such as the Cerbo GX, or directly via a laptop with VE.Bus Smart Dongle. Parallel stacking of up to six units is supported, and three-phase configurations are possible with three units, giving significant scalability for commercial or larger residential off-grid systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP242505010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e120A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052913\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and smallholding installations with 24V battery banks.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat systems requiring high-capacity inverter charging from shore power or a generator.\u003c\/li\u003e\n  \u003cli\u003eBackup power for commercial premises where grid outages cannot be tolerated.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar systems combined with a Victron MPPT charge controller and GX monitoring device.\u003c\/li\u003e\n  \u003cli\u003eVehicle and expedition builds where 5000VA output is needed from a 24V system.\u003c\/li\u003e\n  \u003cli\u003eScalable multi-unit installations requiring parallel or three-phase output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron MultiPlus-II 24\/5000\/120-50 230V inverter charger unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 24\/5000\/120-50 must be installed by a qualified electrician or accredited installer. At 5000VA and 120A charge current on a 24V system, DC cable sizing, fusing and busbar connections are critical and must comply with current wiring regulations. For any grid-connected or generator-connected installation in the UK, compliance with G98 or G99 requirements must be assessed by a qualified engineer. Lithium battery installations require correct configuration of charge parameters via VE.Bus or VictronConnect before commissioning. The unit weighs 32 kg and requires secure, ventilated wall or panel mounting.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55582468145443,"sku":"PMP242505010","price":1403.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/Multiplus-II24V5kVA120-50230V_front.jpg?v=1789118055","url":"https:\/\/voltaconsolar.eu\/products\/victron-multiplus-ii-24-5000-120-50-230v","provider":"VoltaconSolar EU","version":"1.0","type":"link"}