{"product_id":"victron-inverter-24-5000-230v-ve-bus","title":"Victron Inverter 24\/5000 230V VE.Bus - PIN245020000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter 24\/5000 230V VE.Bus — PIN245020000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter 24\/5000 230V VE.Bus is a high-capacity 5000VA pure sine wave inverter designed for 24V DC battery systems with 230V AC output. It is built for professional off-grid installations, marine and vehicle applications, and backup power systems where a reliable, high-power AC supply is required from a DC battery bank.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5000VA continuous output power from a 24V DC battery bank, suitable for demanding loads.\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output at 230V AC, compatible with sensitive electronics and motor-driven equipment.\u003c\/li\u003e\n  \u003cli\u003eVE.Bus communication interface allows integration with Victron system components including Multi and Quattro units, GX devices, and remote monitoring panels.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase configuration when used with compatible Victron VE.Bus inverters.\u003c\/li\u003e\n  \u003cli\u003eCompact and scalable design for professional system builds requiring high output in a single unit.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron's VEConfigure software for detailed parameter configuration and system tuning.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protections including over-temperature, overload, and short-circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 24\/5000 operates from a 24V nominal battery bank and delivers 5000VA of continuous AC power at 230V. The VE.Bus interface is central to its value in professional installations: it allows the inverter to communicate directly with other Victron VE.Bus devices, enabling parallel stacking for increased capacity or three-phase configurations for commercial and industrial applications. This makes it a practical choice where a single inverter is not sufficient and the system needs to scale.\u003c\/p\u003e\n\n\u003cp\u003eVE.Bus connectivity also enables integration with Victron GX monitoring devices such as the Cerbo GX, giving installers full visibility of system performance via the VRM online portal. Configuration is handled through VEConfigure, which allows adjustment of operational thresholds, transfer settings, and protection parameters to suit the specific installation. The unit weighs 28kg, which reflects the transformer-based design that underpins its output quality and surge handling capability.\u003c\/p\u003e\n\n\u003cp\u003eAs a standalone inverter (not a charger-inverter), the 24\/5000 does not include a battery charger or AC transfer switch. It is intended for systems where charging is handled separately, for example by a solar charge controller or a dedicated battery charger. Installers should account for this when designing the system architecture.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN245020000\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal DC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5000VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e28 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076023760\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins, lodges and remote buildings requiring high-power AC supply from a battery bank.\u003c\/li\u003e\n  \u003cli\u003eMarine vessels with 24V DC systems needing 230V AC output for onboard equipment.\u003c\/li\u003e\n  \u003cli\u003eLarge vehicle and mobile installations such as coaches, expedition vehicles and broadcast units.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for commercial or industrial premises where mains supply is unreliable.\u003c\/li\u003e\n  \u003cli\u003eScalable multi-inverter systems using VE.Bus parallel or three-phase stacking.\u003c\/li\u003e\n  \u003cli\u003eIntegration into Victron-based energy systems monitored via Cerbo GX and VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter 24\/5000 230V VE.Bus unit (PIN245020000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter operates at 24V DC with high continuous current draw at full load. DC cabling, fusing and busbar sizing must be correctly rated for the current involved. Installation should be carried out by a qualified electrician or accredited installer familiar with DC power systems and Victron equipment. For any grid-connected or backup applications interfacing with the mains supply, compliance with current UK wiring regulations (BS 7671) and relevant DNO requirements is the installer's responsibility. VE.Bus configuration requires Victron's VEConfigure software and a suitable interface cable or MK3-USB adapter.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632588996899,"sku":"PIN245020000","price":1497.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-phoenix-inverter-245000-230v-vebus-pin245020000-835170.jpg?v=1789114870","url":"https:\/\/voltaconsolar.eu\/products\/victron-inverter-24-5000-230v-ve-bus","provider":"VoltaconSolar EU","version":"1.0","type":"link"}