{"product_id":"victron-inverter-12-250-230v-ve-direct-iec","title":"Victron Inverter 12\/250 230V VE.Direct IEC - PIN121251100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter 12\/250 230V VE.Direct IEC\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter 12\/250 is a compact 250VA pure sine wave inverter designed to convert 12V DC battery power to 230V AC. It is suited to small off-grid loads, mobile installations and backup applications where a lightweight, reliable inverter is needed without the complexity of a full inverter\/charger.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e250VA continuous output at 230V AC from a 12V DC battery bank\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output compatible with sensitive electronics and inductive loads\u003c\/li\u003e\n  \u003cli\u003eVE.Direct port for monitoring and configuration via Victron GX devices or the VictronConnect app\u003c\/li\u003e\n  \u003cli\u003eIEC socket output for direct appliance connection without additional wiring\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 2.6 kg, suitable for space-constrained installations\u003c\/li\u003e\n  \u003cli\u003eBuilt-in protection against low battery voltage, overload and over-temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 12\/250 sits at the entry level of Victron's VE.Direct inverter range. At 250VA, it is not intended for high-draw appliances, but it handles small continuous loads such as LED lighting, phone and laptop charging, small fans and low-power tools effectively. The pure sine wave output means it will not cause issues with switch-mode power supplies or motors that a modified sine wave inverter might.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Direct interface sets this unit apart from basic inverters. It allows integration with Victron's monitoring ecosystem, including the Cerbo GX and Color Control GX, giving installers and end users visibility of inverter status, load and fault conditions through the VRM portal. This makes it a practical choice for small off-grid systems where monitoring is still required.\u003c\/p\u003e\n\n\u003cp\u003eThe IEC output socket allows direct connection of standard IEC-fitted appliances. Protection circuits cover low battery cutoff, overload shutdown and thermal protection, all of which reset automatically once the fault condition clears.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN121251100\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Output Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Socket\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIEC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2.6 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076047117\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall off-grid cabins or shelters with limited 12V battery storage\u003c\/li\u003e\n  \u003cli\u003eCampervans and motorhomes requiring a 230V AC outlet for low-power devices\u003c\/li\u003e\n  \u003cli\u003eMarine installations needing a compact 230V source from a 12V bank\u003c\/li\u003e\n  \u003cli\u003eBackup power for small loads such as routers, lighting or phone charging\u003c\/li\u003e\n  \u003cli\u003eMonitoring-integrated off-grid systems using Victron GX devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter 12\/250 230V VE.Direct IEC unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis inverter connects directly to a 12V DC battery bank. DC cable sizing and fusing must be appropriate for the current draw at full load. Installation should be carried out by a qualified electrician or experienced installer. The unit is not grid-connected and does not require G98 or G99 notification, but all AC wiring from the IEC output must comply with current UK wiring regulations (BS 7671).\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55582577197347,"sku":"PIN121251100","price":81.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/VoltaconSolar_-_PIN121251100_-_Inverter_12-250_230V_VE.Direct_IEC.webp?v=1789120695","url":"https:\/\/voltaconsolar.eu\/products\/victron-inverter-12-250-230v-ve-direct-iec","provider":"VoltaconSolar EU","version":"1.0","type":"link"}