{"product_id":"victron-ev-charging-station-ns-blue","title":"Victron EV Charging station NS - Blue - EVC200300200","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy EV Charging Station NS – Blue\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy EV Charging Station NS is a compact, single-phase AC EV charger designed for residential and light commercial use. It integrates with Victron's GX ecosystem, making it a practical choice for solar and off-grid installations where dynamic load management and solar self-consumption are priorities.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCompatible with Victron GX devices for dynamic power control and solar integration.\u003c\/li\u003e\n  \u003cli\u003eSupports Mode 3 charging with a Type 2 (IEC 62196) connector standard.\u003c\/li\u003e\n  \u003cli\u003eAdjustable charging current allows the system to respond to available solar generation or grid capacity.\u003c\/li\u003e\n  \u003cli\u003eCompact, wall-mounted design with a blue housing suitable for indoor and sheltered outdoor installation.\u003c\/li\u003e\n  \u003cli\u003eCommunicates via Modbus TCP, enabling integration with Victron's VRM portal and Venus OS.\u003c\/li\u003e\n  \u003cli\u003eWeighs 2.5 kg, making it straightforward to handle and mount during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EV Charging Station NS connects directly to Victron's GX control layer, allowing the charger's output to be modulated in real time based on excess solar production, battery state of charge, or grid import limits. This makes it particularly useful in systems where the installer wants to prioritise self-consumption rather than drawing from the grid to charge a vehicle.\u003c\/p\u003e\n\n\u003cp\u003eThe NS variant is the non-smart (no built-in display) version of Victron's EV charger range, keeping the form factor compact while retaining full network communication capability via Modbus TCP. Configuration and monitoring are handled through a connected GX device or the VRM portal, rather than a local touchscreen. This suits installations where the charger is mounted in a utility area and remote monitoring is preferred.\u003c\/p\u003e\n\n\u003cp\u003eThe blue housing distinguishes this unit from the white variant. Both share the same electrical specification. The unit is wall-mounted and designed for fixed installation by a qualified electrician.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eEVC200300200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076058274\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eType 2 (IEC 62196)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharging Mode\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMode 3 (AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eModbus TCP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eColour\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBlue\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWall-mounted\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSolar self-consumption EV charging, where surplus PV generation is directed to the vehicle rather than exported.\u003c\/li\u003e\n  \u003cli\u003eResidential installations integrated with a Victron Multiplus or Quattro inverter\/charger system.\u003c\/li\u003e\n  \u003cli\u003eOff-grid and hybrid systems requiring dynamic charge current adjustment based on battery or generator capacity.\u003c\/li\u003e\n  \u003cli\u003eLight commercial premises with a Victron GX device already managing energy flow.\u003c\/li\u003e\n  \u003cli\u003eInstallations where remote monitoring via VRM portal is preferred over a local display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron EV Charging Station NS (Blue)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit must be installed by a qualified electrician in accordance with BS 7671 (IET Wiring Regulations) and any applicable local building regulations. A dedicated circuit with appropriate overcurrent and RCD protection is required. For integration with a Victron GX device, a network connection (Ethernet) must be available at the installation point. If the installation is connected to the public grid, confirm compliance with your Distribution Network Operator's requirements before commissioning.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52717336264995,"sku":"EVC200300200","price":485.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/EVC200300200-EVChargingstationNS_Blue_top-greenLED_19940ff1-d102-4359-bf63-8349d1cc8858.webp?v=1789114677","url":"https:\/\/voltaconsolar.eu\/products\/victron-ev-charging-station-ns-blue","provider":"VoltaconSolar EU","version":"1.0","type":"link"}