{"title":"Victron Battery Protection","description":"","products":[{"product_id":"victron-battery-protect-48-100a","title":"Victron BatteryProtect 48V 100A - BPR048100400","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003c\/p\u003e\n\u003cp\u003eThe BatteryProtect is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the Battery terminal to the Load terminal. In case of use with a load, the battery connects to the Battery terminal, and in case of use with a charger, the charger connects to the Battery terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Battery Protect 48V 100A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003cbr\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003cbr\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgramming made easy\u003c\/strong\u003e\u003cbr\u003eThe BatteryProtect 48V 100A can be set to engage \/ disengage at several different voltages.\u003cbr\u003eThe seven segment display will indicate which setting has been chosen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003cbr\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003cbr\u003eThe load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003cbr\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551510307,"sku":"BPR048100400","price":127.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-batteryprotect-48v-100a-bpr048100400-779734.jpg?v=1709566792"},{"product_id":"victron-battery-protect-12-24-65a","title":"Victron BatteryProtect 12\/24V 65A - BPR000065400","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine - Victron BatteryProtect 12\/24V 65A - BPR000065400\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe BatteryProtect is not designed for reverse currents from charging sources.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA special setting for Li-ion batteries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn this mode the BatteryProtect can be controlled by the VE.Bus BMS.\u003cbr\u003eNote: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-low current consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is important in case of Li-ion batteries, especially after low voltage shutdown.\u003c\/p\u003e\n\u003cp\u003ePlease see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003c\/p\u003e\n\u003cp\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551575843,"sku":"BPR000065400","price":52.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-batteryprotect-1224v-65a-bpr000065400-448096.jpg?v=1709566610"},{"product_id":"victron-battery-protect-12-24-100a","title":"Victron BatteryProtect 12\/24V 100A - BPR000100400","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine - Victron BatteryProtect 12\/24V 100A - BPR000100400\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe BatteryProtect is not designed for reverse currents from charging sources.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA special setting for Li-ion batteries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn this mode the BatteryProtect can be controlled by the VE.Bus BMS.\u003cbr\u003eNote: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-low current consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is important in case of Li-ion batteries, especially after low voltage shutdown.\u003c\/p\u003e\n\u003cp\u003ePlease see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003c\/p\u003e\n\u003cp\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551641379,"sku":"BPR000100400","price":69.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-batteryprotect-1224v-100a-bpr000100400-137774.jpg?v=1709566942"},{"product_id":"battery-balancer-victron","title":"Victron Battery Balancer - BBA000100100","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cp\u003eThe equalizer is proven to extend the life span of the batteries and increase the efficiency of the energy storage. All the batteries will equally supply the maximum amperage when the voltages are properly balanced. \u003c\/p\u003e\n\u003cp\u003eThe Battery Balancer equalizes the state of charge of two series connected 12V batteries, or of several parallel strings of series connected batteries. When the charge voltage of a 24V battery system increases to more than 27V, the Battery Balancer will turn on and compare the voltage over the two series connected batteries. The Battery Balancer will draw a current of up to 1A from the battery (or parallel connected batteries) with the highest voltage. The resulting charge current differential will ensure that all batteries will converge to the same state of charge.\u003c\/p\u003e\n\u003cp\u003eIf needed, several balancers can be paralleled.\u003cbr\u003eA 48V battery bank can be balanced with three Battery Balancers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDemo\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith the Battery Balancer demo web-app you can demonstrate on your phone or tablet how the battery balancer works. There are two sliders on each side of the screen. With these sliders you can create an out of balance battery system. As soon as you release the slider, the balancer will then operate based on the specifications in the data-sheet. The onscreen LEDs and energy flow will react accordingly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"sectionedit3\" id=\"steps_to_install_it_as_a_web-app\"\u003e\u003cstrong\u003eSteps to install it as a web-app\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"level2\"\u003e\n\u003cp\u003eThe screenshots below have been made with an iPhone. The procedure is the same for Android and Windows phones and tablets.\u003c\/p\u003e\n\u003cp\u003eSteps (see images below)\u003c\/p\u003e\n\u003col\u003e\n\u003cli class=\"level1\"\u003e\n\u003cdiv class=\"li\"\u003eVisit\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"http:\/\/bb-demo.victronenergy.com\/\" class=\"urlextern\" title=\"http:\/\/bb-demo.victronenergy.com\"\u003ehttp:\/\/bb-demo.victronenergy.com\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ein your mobile-browser (safari).\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"level1\"\u003e\n\u003cdiv class=\"li\"\u003eSelect the share\/export-icon.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"level1\"\u003e\n\u003cdiv class=\"li\"\u003eSelect ‘Add to home screen‘.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"level1\"\u003e\n\u003cdiv class=\"li\"\u003eSelect ‘Add‘ when the battery-balancer-icon is visible.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"level1\"\u003e\n\u003cdiv class=\"li\"\u003eStart the web-app (once you have been online and downloaded it initially).\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551674147,"sku":"BBA000100100","price":72.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-battery-balancer-bba000100100-441685.jpg?v=1709566615"},{"product_id":"victron-battery-protect-12-24-220a","title":"Victron BatteryProtect 12\/24V 220A - BPR000220400","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine - \u003cspan data-mce-fragment=\"1\"\u003eVictron BatteryProtect 12\/24V 220A - BPR000220400\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe BatteryProtect is not designed for reverse currents from charging sources.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA special setting for Li-ion batteries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn this mode the BatteryProtect can be controlled by the VE.Bus BMS.\u003cbr\u003eNote: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-low current consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is important in case of Li-ion batteries, especially after low voltage shutdown.\u003c\/p\u003e\n\u003cp\u003ePlease see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003c\/p\u003e\n\u003cp\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551837987,"sku":"BPR000220400","price":104.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-batteryprotect-1224v-220a-bpr000220400-852956.jpg?v=1709566624"},{"product_id":"victron-battery-switch-on-off-275a","title":"Victron Battery Switch On\/Off 275A - VBS127010010","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Battery Switch ON\/OFF 275A is suitable for battery systems up to 48V. It has a unique ergonomic and aesthetic knob design. The knob is removable for isolation or safety purposes.\u003c\/p\u003e\n\u003cp\u003eThe Battery Switch ON\/OFF 275A is suitable for battery systems up to 48V. It has a unique ergonomic and aesthetic knob design. The knob is removable for isolation or safety purposes.\u003c\/p\u003e\n\u003cp\u003eThe Battery Switch can be either surface or panel-mounted, providing flexibility during installation.\u003c\/p\u003e\n\u003cp\u003eThe Battery Switch meets the ISO8846 Ignition Protection standard and is suitable for use in an engine room.\u003c\/p\u003e\n\u003cp\u003eBattery isolation switch for when being left for periods of time or to be used as a safety switch when working on the battery.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. continuous current 275 A\u003c\/li\u003e\n\u003cli\u003eOne minute rating 455 A\u003c\/li\u003e\n\u003cli\u003eCranking rating 1250 A\u003c\/li\u003e\n\u003cli\u003eVoltage rating 48 V\u003c\/li\u003e\n\u003cli\u003eTerminal material Tin-plated copper\u003c\/li\u003e\n\u003cli\u003eHex nut material Tin-plated copper\u003c\/li\u003e\n\u003cli\u003eTerminal diameter 3\/8 inch \/ 9.53 mm\u003c\/li\u003e\n\u003cli\u003eRecommended torque 70 lbf·inch \/ 8 N·m\u003c\/li\u003e\n\u003cli\u003eBase material Glass fibre reinforced nylon\u003c\/li\u003e\n\u003cli\u003eWeight 200g\u003c\/li\u003e\n\u003cli\u003eDimensions (hxwxd) 69 x 69 x 73 mm\u003c\/li\u003e\n\u003cli\u003eMounting Surface or rear panel mount\u003c\/li\u003e\n\u003cli\u003eIgnition protected ISO8846 \/ SAE J1171\u003c\/li\u003e\n\u003cli\u003eVictron Energy part number VBS127010010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632552263971,"sku":"VBS127010010","price":32.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-battery-switch-onoff-275a-vbs127010010-923035.jpg?v=1709566945"},{"product_id":"victron-smart-battery-protect-12-24-100a","title":"Victron Smart BatteryProtect 12\/24V 100A - BPR110022000","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 100A disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003c\/p\u003e\n\u003cp\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003c\/p\u003e\n\u003cp\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 100A is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Battery Protect 12\/24V 100A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003cbr\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect 12\/24V 100A automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth: programming made easy\u003c\/strong\u003e\u003cbr\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003cbr\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003cbr\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003cbr\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003cbr\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.\u003cbr\u003eStarting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003cbr\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003cbr\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor, operate \u0026amp; control your system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the VictronConnect app to configure, monitor, update and diagnose your Smart BatteryProtect. It can connect to Victron products via Bluetooth, USB and WiFi\/LAN\/Internet.\u003c\/p\u003e\n\u003cp\u003eSee the VictronConnect product page for more information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632559997219,"sku":"BPR110022000","price":87.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-smart-batteryprotect-1224v-100a-bpr110022000-142821.jpg?v=1709566893"},{"product_id":"victron-smart-battery-protect-12-24-220a","title":"Victron Smart BatteryProtect 12\/24V 220A - BPR122022000","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 220A disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003c\/p\u003e\n\u003cp\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003c\/p\u003e\n\u003cp\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 220A is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Battery Protect 12\/24V 220A \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003cbr\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect 12\/24V 220A automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth: programming made easy\u003c\/strong\u003e\u003cbr\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003cbr\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003cbr\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003cbr\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003cbr\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.\u003cbr\u003eStarting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003cbr\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003cbr\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor, operate \u0026amp; control your system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the VictronConnect app to configure, monitor, update and diagnose your Smart BatteryProtect. It can connect to Victron products via Bluetooth, USB and WiFi\/LAN\/Internet.\u003c\/p\u003e\n\u003cp\u003eSee the VictronConnect product page for more information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632560029987,"sku":"BPR122022000","price":118.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-smart-batteryprotect-1224v-220a-bpr122022000-353667.jpg?v=1709566893"},{"product_id":"victron-smart-battery-protect-12-24-65a","title":"Victron Smart BatteryProtect 12\/24V 65A - BPR065022000","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 65A disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003c\/p\u003e\n\u003cp\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003c\/p\u003e\n\u003cp\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect 12\/24V 65A is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Battery Protect 12\/24V 65A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003cbr\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12\/24V auto ranging\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect 12\/24V 65A automatically detects system voltage one time only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth: programming made easy\u003c\/strong\u003e\u003cbr\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003cbr\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003cbr\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003cbr\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003cbr\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.\u003cbr\u003eStarting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003cbr\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003cbr\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor, operate \u0026amp; control your system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the VictronConnect app to configure, monitor, update and diagnose your Smart BatteryProtect. It can connect to Victron products via Bluetooth, USB and WiFi\/LAN\/Internet.\u003c\/p\u003e\n\u003cp\u003eSee the VictronConnect product page for more information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632560324899,"sku":"BPR065022000","price":70.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-smart-batteryprotect-1224v-65a-bpr065022000-274571.jpg?v=1709566702"},{"product_id":"small-bms-bms400100000","title":"Victron SmallBMS - BMS400100000","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe simple and small BMS recommended for small systems\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003eA simple and low cost alternative to the VE.Bus BMS V2 The smallBMS can replace the VE.Bus BMS V2 in several applications. It is however not suitable for use with VE.Bus MultiPlus and Quattro inverter\/chargers: it has no VE.Bus interface. The smallBMS is intended for use with Victron Smart LiFePo4 batteries with M8 circular connectors. The smallBMS has two outputs, similar to the VE.Bus BMS V2.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632560357667,"sku":"BMS400100000","price":49.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-smallbms-bms400100000-738036.jpg?v=1709567022"},{"product_id":"ve-bus-bms-v2-bms300200200","title":"Victron VE.Bus BMS V2 - BMS300200200","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003eExternal BMS device that communicates and protects Victron Lithium Ion Batteries\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe VE.Bus BMS V2 is a Battery Management System (BMS) designed to interface with and protect a single, or multiple Victron Lithium Battery Smart 12,8V \u0026amp; 25,6V (LiFePO4 or LFP) in systems that have Victron inverters or inverter\/chargers with VE.Bus communication. It monitors and protects the batteries against over voltage and under voltage of any individual cell, and also over temperature or under temperature conditions.\u003c\/p\u003e\n\u003cp\u003eBased on the status of the battery or batteries, the BMS will:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate a pre-alarm signal to alert of an imminent cell under voltage conditions.\u003c\/li\u003e\n\u003cli\u003eDisable inverting in VE.Bus inverters or inverter\/chargers via VE.Bus, and disable other loads via the 'Load Disconnect' terminal in the event of a cell under voltage condition.\u003c\/li\u003e\n\u003cli\u003eDisable charging in VE.Bus inverters or inverter\/chargers via VE.Bus and disable other chargers via the 'Charge Disconnect' terminal in the event of a cell overvoltage, under temperature or over-temperature conditions.\u003c\/li\u003e\n\u003cli\u003eRemote on\/off terminals.\u003c\/li\u003e\n\u003cli\u003eAbility to disable VE.Direct and VE.Can solar chargers via a GX device.\u003c\/li\u003e\n\u003cli\u003eAllowing control of the VE.Bus inverter\/charger from multiple devices, like the Digital Multi Control, the VE.Bus Smart dongle and\/or a GX device.\u003c\/li\u003e\n\u003cli\u003eAuxiliary power input and output terminals that allow a GX device to remain powered in the event of a system shutdown.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632563798307,"sku":"BMS300200200","price":157.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-vebus-bms-v2-bms300200200-719307.jpg?v=1709566715"},{"product_id":"victron-smart-battery-protect-48v-100a","title":"Victron Smart BatteryProtect 48V 100A - BPR110048000","description":"\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\" itemprop=\"short_description\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Smart BatteryProtect 48V 100A disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003c\/p\u003e\n\u003cp\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003c\/p\u003e\n\u003cp\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003eThe Smart BatteryProtect 48V 100A is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures of the Battery Protect 48V 100A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtects the battery against excessive discharge and can be used as a system on\/off switch\u003c\/strong\u003e\u003cbr\u003eThe Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.\u003cbr\u003eThe on\/off input can be used as a system on\/off switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth: programming made easy\u003c\/strong\u003e\u003cbr\u003eWhen using Bluetooth to program the Smart BatteryProtect any required engage\/disengage levels can be set.\u003cbr\u003eAlternatively, one of nine predefined engage\/disengage levels can be set with the programming pin.\u003cbr\u003eIf required, Bluetooth can be disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003cbr\u003eTo prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIgnition proof\u003c\/strong\u003e\u003cbr\u003eNo relays but MOSFET switches, and therefore no sparks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed alarm output\u003c\/strong\u003e\u003cbr\u003eThe alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.\u003cbr\u003eStarting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDelayed load disconnect and delayed reconnect\u003c\/strong\u003e\u003cbr\u003eThe load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.\u003cbr\u003eThe load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor, operate \u0026amp; control your system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the VictronConnect app to configure, monitor, update and diagnose your Smart BatteryProtect. It can connect to Victron products via Bluetooth, USB and WiFi\/LAN\/Internet.\u003c\/p\u003e\n\u003cp\u003eSee the VictronConnect product page for more information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632589127971,"sku":"BPR110048000","price":174.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/products\/victron-smart-batteryprotect-48v-100a-bpr110048000-915886.jpg?v=1709566893"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/collections\/victron-battery-protection-256597.jpg?v=1709566512","url":"https:\/\/voltaconsolar.eu\/en-de\/collections\/victron-battery-protection.oembed","provider":"VoltaconSolar EU","version":"1.0","type":"link"}