{"title":"Victron","description":"\u003cspan data-mce-fragment=\"1\"\u003eVictron Energy has a strong, unrivalled reputation for technical innovation, reliability, and build quality. Their products are widely considered to be the professional choice for independent electric power.\u003c\/span\u003e","products":[{"product_id":"victron-ac-current-sensor-single-phase-40a","title":"Victron AC Current sensor - single phase - max 40A - CSE000100000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron AC Current Sensor - Single Phase - Max 40A\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron AC Current Sensor is a single-phase current monitoring accessory designed for use with Victron GX devices. It measures AC current up to 40A and feeds live data into the GX system, giving installers and operators accurate consumption or generation readings without the need for a dedicated energy meter.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMeasures single-phase AC current up to a maximum of 40A.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices including the Cerbo GX and Color Control GX.\u003c\/li\u003e\n  \u003cli\u003eClamp-style sensor fits around a single conductor without breaking the circuit.\u003c\/li\u003e\n  \u003cli\u003eConnects directly to the GX device via the dedicated AC sensor input.\u003c\/li\u003e\n  \u003cli\u003eEnables monitoring of AC loads, grid input or generator output within the VRM portal.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 83g, suitable for installation in compact enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a current transformer (CT) clamp principle. It clamps around a single live conductor and outputs a signal proportional to the current flowing through it. The GX device interprets this signal and displays real-time wattage and energy data in the local interface and on the VRM online portal. No additional shunt or meter is required for basic current monitoring.\u003c\/p\u003e\n\n\u003cp\u003eAt a 40A maximum rating, this sensor covers most single-phase residential and light commercial loads. It is particularly useful where a full energy meter installation is not practical or where a specific circuit needs to be monitored independently, such as a generator feed, a critical load output, or a sub-circuit within a larger system.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is a factory-terminated unit with a fixed cable and connector. It is designed to plug directly into compatible Victron GX hardware. Check your GX device documentation to confirm the AC sensor input is available and not already occupied before ordering multiple units.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CSE000100000\u003c\/li\u003e\n  \u003cli\u003eMaximum AC current: 40A\u003c\/li\u003e\n  \u003cli\u003ePhase configuration: Single phase\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.083 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076022107\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitoring AC load consumption on a single-phase circuit within a Victron system.\u003c\/li\u003e\n  \u003cli\u003eMeasuring generator output current feeding a Victron inverter\/charger.\u003c\/li\u003e\n  \u003cli\u003eTracking grid import or export on a sub-circuit not covered by the main energy meter.\u003c\/li\u003e\n  \u003cli\u003eOff-grid and hybrid solar installations where circuit-level current data is required.\u003c\/li\u003e\n  \u003cli\u003eLight commercial installations with a dedicated monitored load circuit up to 40A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron AC Current Sensor (single phase, 40A maximum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe sensor clamps around a single conductor only. Do not clamp around a twin-and-earth or multicore cable, as this will produce an incorrect or zero reading. Installation should be carried out by a qualified electrician. For solar PV and grid-connected systems, ensure all work complies with UK wiring regulations and any applicable G98 or G99 requirements. Confirm GX device firmware is up to date to ensure full sensor compatibility.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632479191331,"sku":"CSE000100000","price":46.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/ac-current-sensor-single-phase-max-40a-cse000100000-754781.jpg?v=1789115684"},{"product_id":"victron-ccgx-wifi-module-simple-nano-usb","title":"Victron CCGX WiFi module simple (Nano USB) - BPP900100200","description":"\u003ch1 style=\"color: #f87c24;\"\u003eCCGX WiFi Module Simple (Nano USB) — BPP900100200\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron CCGX WiFi Module Simple is a compact Nano USB adapter that adds wireless network connectivity to compatible Victron GX devices. It is designed for installers who need to connect a Color Control GX or similar GX product to a local WiFi network without running an Ethernet cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNano USB form factor — plugs directly into the USB port of compatible Victron GX devices with minimal protrusion.\u003c\/li\u003e\n  \u003cli\u003eAdds WiFi connectivity to GX devices that do not have built-in wireless networking.\u003c\/li\u003e\n  \u003cli\u003eEnables remote monitoring and configuration via the Victron Remote Management (VRM) portal over a local WiFi network.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the Color Control GX (CCGX) and other Victron GX-series products that support USB WiFi adapters.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.03 kg, making it straightforward to include in any installation kit or panel build.\u003c\/li\u003e\n  \u003cli\u003eSimple plug-and-play setup — no additional drivers or software installation required on the GX device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMany Victron GX devices are installed in locations where running a wired Ethernet connection is impractical. This Nano USB WiFi module provides a direct solution by allowing the GX device to connect to an existing WiFi network. Once connected, the GX device can push data to the VRM portal, enabling remote monitoring of system performance, alarms and historical data from any internet-connected device.\u003c\/p\u003e\n\n\u003cp\u003eThe Nano USB format keeps the adapter flush against the GX device, which matters in enclosures or panel builds where space is limited. Victron officially supports this adapter for use with their GX product range, so there is no need to source a generic third-party USB WiFi dongle and risk compatibility issues. For installations where a wired connection is available, a standard Ethernet connection remains the more reliable option, but this module is a practical choice where cabling is not feasible.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPP900100200\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021377\u003c\/li\u003e\n  \u003cli\u003eConnector type: USB (Nano form factor)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.03 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible device category: Victron GX Products (e.g. Color Control GX)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdding WiFi connectivity to a Color Control GX in a residential solar installation where Ethernet is not available.\u003c\/li\u003e\n  \u003cli\u003eOff-grid and mobile installations (motorhomes, boats, cabins) where a wired network connection is not practical.\u003c\/li\u003e\n  \u003cli\u003eRetrofit installations where an existing GX device needs to be brought onto a WiFi network for VRM monitoring.\u003c\/li\u003e\n  \u003cli\u003eCommercial installations requiring remote monitoring access without additional network infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x CCGX WiFi Module Simple (Nano USB) — BPP900100200\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInsert the Nano USB adapter into an available USB port on the compatible GX device. Network configuration is handled through the GX device's own settings menu. While this accessory does not involve high-voltage wiring, it should be installed as part of a complete system configured by a qualified installer familiar with Victron GX products. Ensure the GX device firmware is up to date to maintain compatibility with the WiFi module.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632483615011,"sku":"BPP900100200","price":19.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/ccgx-wifi-module-simple-nano-usb-bpp900100200-220786.jpg?v=1789115614"},{"product_id":"current-transformer-100a-50ma-multiplus-ii-20m-disc","title":"Victron Curr.XMFR100A:50mA MultiPl.-II(20m)*Available until stock 0* - CTR110002050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eCurrent Transformer 100A:50mA for Victron MultiPlus-II\u003c\/h1\u003e\n\u003cp\u003eThe Current Transformer 100A:50mA is used with Victron MultiPlus-II inverter\/chargers and GX devices to measure current on a busbar or cable up to 100A. It provides accurate current sensing for systems that need external metering input, such as PV inverter monitoring or grid feed-in measurement. This unit comes with a 20 metre cable, making it suitable for installations where the GX device or MultiPlus-II is located some distance from the measurement point.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent transformer rated 100A:50mA, suitable for accurate current measurement on cables or busbars up to 100A.\u003c\/li\u003e\n\u003cli\u003eSupplied with a 20 metre cable, allowing installation in cabinets or distribution boards away from the GX device or MultiPlus-II.\u003c\/li\u003e\n\u003cli\u003eCompatible with Victron MultiPlus-II inverter\/chargers for external current sensing applications.\u003c\/li\u003e\n\u003cli\u003eCompact clamp-style design allows fitting around an existing conductor without breaking the circuit.\u003c\/li\u003e\n\u003cli\u003eWeighs 0.7 kg, making it straightforward to mount within an enclosure or panel.\u003c\/li\u003e\n\u003cli\u003eGTIN 8719076057161 for stock identification and ordering reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThis current transformer works by generating a proportional low current output (50mA) for every 100A measured on the monitored conductor. That scaled signal is fed into a MultiPlus-II or compatible GX device, allowing the system to read and log current flow without direct high current wiring into the monitoring equipment. This is a common requirement in systems where a Victron installation needs to track current from a separate source, such as a grid connection or a second inverter, and use that data for control logic or monitoring dashboards.\u003c\/p\u003e\n\u003cp\u003eThe 20 metre cable length is worth noting for planning purposes. On larger installations, the physical distance between the current measurement point and the GX device or MultiPlus-II can be significant, particularly in commercial or plant room environments. Specifying the correct cable length at the point of purchase avoids the need for extensions or additional junctions, which can introduce measurement error or points of failure.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring grid import and export current in hybrid or ESS installations using Victron GX devices.\u003c\/li\u003e\n\u003cli\u003eProviding external current sensing input to a MultiPlus-II for load or feed-in measurement.\u003c\/li\u003e\n\u003cli\u003eRetrofitting current monitoring to existing distribution boards without rewiring the main conductors.\u003c\/li\u003e\n\u003cli\u003eCommercial and off-grid installations where the GX device is located away from the point of current measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Current Transformer 100A:50mA\u003c\/li\u003e\n\u003cli\u003e20 metre connecting cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis product should be installed by a qualified electrician, as it is fitted around live conductors as part of the current monitoring circuit. Confirm compatibility with your specific MultiPlus-II or GX device configuration before installation. Note that this item is available until current stock is depleted.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632487448867,"sku":"CTR110002050","price":47.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/current-transformer-100a50ma-for-multiplus-ii-20m-ctr110002050-297192.jpg?v=1789115584"},{"product_id":"current-transformer-100a-50ma-multiplus-ii-5m","title":"Victron Current Transformer 100A:50mA for MultiPlus-II (5m) - CTR110000550","description":"\u003ch1 style=\"color: #f87c24;\"\u003eCurrent Transformer 100A:50mA for MultiPlus-II (5m)\u003c\/h1\u003e\n\n\u003cp\u003eThis current transformer is designed for use with the Victron MultiPlus-II inverter\/charger, providing accurate AC current measurement via a 5-metre cable. It outputs a 50mA signal proportional to the measured current up to 100A, allowing the MultiPlus-II to monitor grid or load current for energy management and control functions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A primary to 50mA secondary ratio, providing a standardised signal for compatible Victron equipment.\u003c\/li\u003e\n  \u003cli\u003e5-metre cable length gives sufficient reach for most installation configurations without extension.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for use with the Victron MultiPlus-II inverter\/charger series.\u003c\/li\u003e\n  \u003cli\u003eClamp-style transformer fits around a single AC conductor without breaking the circuit.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 85g, making it straightforward to route and secure within an enclosure.\u003c\/li\u003e\n  \u003cli\u003eSKU CTR110000550, GTIN 8719076054634, supplied by Victron Energy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eCurrent transformers (CTs) work by inducing a proportional secondary current when an AC conductor passes through the core. This unit produces a 50mA output when 100A flows through the primary conductor, which the MultiPlus-II uses to measure current accurately without direct electrical connection to the high-current circuit. This isolation is both a safety feature and a practical advantage in installations where the measurement point is remote from the inverter.\u003c\/p\u003e\n\n\u003cp\u003eThe 5-metre cable allows the CT to be positioned at the point of measurement, such as at the main incomer or on a specific load circuit, while the MultiPlus-II remains mounted elsewhere in the installation. This is particularly useful in larger enclosures or where the inverter and metering point are physically separated. The CT is not a general-purpose unit; it is matched to the MultiPlus-II's input requirements and should only be used with compatible Victron equipment.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRatio: 100A : 50mA\u003c\/li\u003e\n  \u003cli\u003eCable length: 5 metres\u003c\/li\u003e\n  \u003cli\u003eCompatible device: Victron MultiPlus-II\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.085 kg (85g)\u003c\/li\u003e\n  \u003cli\u003eSKU: CTR110000550\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076054634\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid current monitoring on MultiPlus-II installations for accurate power management.\u003c\/li\u003e\n  \u003cli\u003eLoad current measurement in off-grid and hybrid solar systems using the MultiPlus-II.\u003c\/li\u003e\n  \u003cli\u003eResidential and light commercial battery storage systems where AC current feedback is required by the inverter\/charger.\u003c\/li\u003e\n  \u003cli\u003eRetrofit installations where a CT was not included with the original MultiPlus-II supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Current Transformer 100A:50mA with 5m cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis CT must be installed by a qualified electrician. It should be fitted around a single AC conductor only; placing it around multiple conductors or a twin-and-earth cable will produce an incorrect or zero reading. Ensure the cable is routed and secured so it cannot be damaged by heat, sharp edges or moving parts. Connection to the MultiPlus-II should follow Victron's wiring guidelines for the specific installation. For grid-connected systems in the UK, the overall installation must comply with G98 or G99 requirements as applicable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632487481635,"sku":"CTR110000550","price":28.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/current-transformer-100a50ma-for-multiplus-ii-5m-ctr110000550-752713.jpg?v=1789115578"},{"product_id":"victron-current-transformer-100a-50ma-multiplus-ii-1m","title":"Victron Current Transformer 100A:50mA for MultiPlus-II (1m) - CTR110000500","description":"\u003ch1 style=\"color: #f87c24;\"\u003eCurrent Transformer 100A:50mA for MultiPlus-II (1m) — CTR110000500\u003c\/h1\u003e\n\n\u003cp\u003eThis current transformer is designed for use with the Victron MultiPlus-II inverter\/charger. It provides accurate AC current measurement by converting up to 100A of AC current to a 50mA signal, allowing the MultiPlus-II to monitor grid or load current without direct high-current wiring into the monitoring circuit. The 1m cable length suits most standard installation configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100A:50mA ratio provides accurate, proportional current measurement across the full operating range.\u003c\/li\u003e\n  \u003cli\u003e1 metre cable length gives sufficient reach for most consumer unit and distribution board installations.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for compatibility with the Victron MultiPlus-II inverter\/charger range.\u003c\/li\u003e\n  \u003cli\u003eSplit-core or clamp-style form factor allows installation around an existing conductor without breaking the circuit.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 55g, making it straightforward to position and secure within an enclosure.\u003c\/li\u003e\n  \u003cli\u003eSKU CTR110000500 with GTIN 8719076044529 for verified product identification and traceability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eCurrent transformers are used in energy monitoring and power management applications where direct measurement of high AC currents is impractical or unsafe. This unit clamps around a live conductor and outputs a scaled-down 50mA signal proportional to the measured current, up to 100A. The MultiPlus-II uses this signal to track AC input or output current in real time, which is essential for accurate power management, grid interaction control, and energy monitoring via the GX ecosystem.\u003c\/p\u003e\n\n\u003cp\u003eThe 100A rating covers the typical single-phase load range found in residential and light commercial installations. Pairing this transformer with the MultiPlus-II enables features such as grid current limiting and ESS (Energy Storage System) control, where the inverter needs to know the actual current flowing at the grid connection point. Without accurate current measurement, these functions cannot operate correctly.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCTR110000500\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransformation Ratio\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A : 50mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCable Length\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1 metre\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible Device\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVictron MultiPlus-II\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e55g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076044529\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid current monitoring in MultiPlus-II ESS (Energy Storage System) installations.\u003c\/li\u003e\n  \u003cli\u003eAC input current limiting to prevent grid overload in residential battery storage systems.\u003c\/li\u003e\n  \u003cli\u003eSingle-phase energy monitoring in off-grid and hybrid solar installations using Victron GX devices.\u003c\/li\u003e\n  \u003cli\u003eRetrofit current measurement in existing MultiPlus-II installations where grid sensing is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Current Transformer 100A:50mA with 1m cable (CTR110000500)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis current transformer must be installed by a qualified electrician. It is intended for use on AC conductors within a consumer unit or distribution board, which involves working in proximity to live mains voltages. Ensure the MultiPlus-II is correctly configured to recognise the CT input before commissioning. For grid-connected systems in the UK, the installation must comply with G98 or G99 requirements as applicable. Do not exceed the 100A rated primary current.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632487514403,"sku":"CTR110000500","price":25.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/current-transformer-100a50ma-for-multiplus-ii-1m-ctr110000500-740258.jpg?v=1789115572"},{"product_id":"victron-energy-meter-em540-3-phase-65a","title":"Victron Energy Meter EM540 - 3 phase - max 65A\/phase - REL200100100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eEnergy Meter EM540 — 3 Phase — Max 65A\/Phase — REL200100100\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Meter EM540 is a three-phase energy meter designed to monitor AC power flows in solar, grid and generator systems. It connects to Victron GX devices and provides real-time energy data across all three phases, up to 65A per phase. It is suited to professional installers working on three-phase residential, commercial and off-grid installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase AC energy monitoring with a maximum current rating of 65A per phase.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices (Cerbo GX, Venus GX, Color Control GX) via RS485 connection.\u003c\/li\u003e\n  \u003cli\u003eCan be configured as a grid meter, PV inverter meter or generator meter within the Victron ecosystem.\u003c\/li\u003e\n  \u003cli\u003eSupports bidirectional measurement, allowing accurate monitoring of both import and export energy flows.\u003c\/li\u003e\n  \u003cli\u003eDIN rail mountable for clean, standard panel installation.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.278 kg, with a compact form factor suitable for distribution boards and metering enclosures.\u003c\/li\u003e\n  \u003cli\u003eWorks with Victron VRM portal for remote monitoring and historical energy data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EM540 measures voltage, current, power factor, frequency and energy (kWh) on each of the three phases independently. When connected to a GX device, this data is displayed in the Victron console and logged to the VRM portal, giving installers and system owners a clear view of energy flows across the installation. The 65A per phase rating covers the majority of three-phase residential and light commercial applications without requiring external current transformers at lower loads.\u003c\/p\u003e\n\n\u003cp\u003eThe meter communicates over RS485 using the Modbus RTU protocol. It connects to the GX device via a VE.Can or USB-to-RS485 interface depending on the GX device in use. Correct addressing and wiring of the RS485 bus is important where multiple meters are installed on the same network. The EM540 replaces the older EM24 in most new installations and is the current recommended meter for three-phase monitoring within the Victron GX product range.\u003c\/p\u003e\n\n\u003cp\u003eWhen used as a grid meter, the EM540 enables ESS (Energy Storage System) functionality on compatible Victron Multi and Quattro inverter\/chargers, allowing the system to optimise battery charge and discharge against grid import and export. This is one of the primary use cases for this meter in UK and EU solar-plus-storage installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eREL200100100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhases\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e65A per phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRS485 \/ Modbus RTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.278 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076061168\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible GX devices\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCerbo GX, Venus GX, Color Control GX and other Victron GX products\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid metering for three-phase Victron ESS installations, enabling accurate import\/export monitoring.\u003c\/li\u003e\n  \u003cli\u003ePV inverter monitoring on three-phase systems where a third-party inverter is present alongside Victron equipment.\u003c\/li\u003e\n  \u003cli\u003eGenerator metering to track fuel consumption and output in off-grid and hybrid systems.\u003c\/li\u003e\n  \u003cli\u003eThree-phase commercial solar-plus-storage installations requiring per-phase energy data.\u003c\/li\u003e\n  \u003cli\u003eRetrofit monitoring on existing three-phase distribution boards where energy visibility is needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy Meter EM540 (3-phase, 65A\/phase)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe EM540 must be installed by a qualified electrician. It connects directly in-line with the AC supply conductors, which involves working within a live distribution board. RS485 wiring to the GX device must be correctly terminated and addressed, particularly where multiple meters share the same bus. For grid-connected ESS systems in the UK, the overall installation must comply with G98 or G99 requirements as applicable. Do not exceed the 65A per phase rating; installations with higher load currents will require external current transformers and a compatible meter variant.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632491381027,"sku":"REL200100100","price":109.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/energy-meter-em540-3-phase-max-65aphase-rel200100100-846609.jpg?v=1789115720"},{"product_id":"victron-ekrano-gx-bpp900480100","title":"Victron Ekrano GX - BPP900480100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Ekrano GX — BPP900480100\u003c\/h1\u003e\n\n\u003cp\u003eThe Ekrano GX is Victron Energy's touchscreen GX monitoring and control device, designed for professional solar, off-grid and backup power installations. It combines a built-in display with the full GX platform, giving installers and system operators direct, on-site visibility and control without a separate panel or external screen. Suitable for residential and light commercial systems where a wall-mounted interface is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated touchscreen display provides on-site system monitoring and control without additional hardware.\u003c\/li\u003e\n  \u003cli\u003eRuns the full Victron GX operating system, compatible with the VRM online portal for remote monitoring.\u003c\/li\u003e\n  \u003cli\u003eConnects to Victron inverter\/chargers, MPPT solar charge controllers, battery monitors and other GX-compatible devices.\u003c\/li\u003e\n  \u003cli\u003eSupports VE.Bus, VE.Direct, VE.Can and Ethernet connectivity for broad system integration.\u003c\/li\u003e\n  \u003cli\u003eWall-mountable form factor suited to plant rooms, battery enclosures and control panels.\u003c\/li\u003e\n  \u003cli\u003eCompact unit weighing 0.56 kg, making it straightforward to mount in space-constrained installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Ekrano GX sits within Victron's GX product family, which acts as the communication and control hub of a Victron system. Where other GX devices such as the Cerbo GX require a separate display, the Ekrano GX integrates the screen directly into the unit. This reduces wiring complexity and the number of components required on the wall, which matters in installations where panel space or cable runs are limited.\u003c\/p\u003e\n\n\u003cp\u003eAs a full GX device, the Ekrano GX logs system data locally and transmits it to the VRM portal when an internet connection is available via Ethernet or a connected router. Installers can configure the system, set charge parameters, monitor state of charge, and view generator or grid input status directly from the touchscreen. This makes it practical for sites where remote access is not always available or where the end user needs a clear, permanent display of system status.\u003c\/p\u003e\n\n\u003cp\u003eThe Ekrano GX is compatible with the full range of Victron GX-compatible equipment. It is not a standalone inverter or charger; it functions as the monitoring, control and communications layer of a Victron installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPP900480100\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076058038\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.56 kg\u003c\/li\u003e\n  \u003cli\u003eCategory: GX Products \/ Remote Panels and Monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems requiring a permanent, wall-mounted monitoring interface.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar and battery backup installations in residential or light commercial premises.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle installations where a compact GX display unit is needed.\u003c\/li\u003e\n  \u003cli\u003eGenerator and grid-tied systems using Victron MultiPlus or Quattro inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eSites where the end user requires direct touchscreen access to system data without logging into a portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Ekrano GX unit (BPP900480100)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Ekrano GX should be installed by a qualified electrician or accredited installer familiar with Victron GX systems. Correct configuration of VE.Bus, VE.Direct and VE.Can connections is essential for accurate system monitoring. For grid-connected installations, ensure the wider system complies with G98 or G99 requirements as applicable. Refer to the system design when selecting communication cables and network topology.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632494068003,"sku":"BPP900480100","price":566.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/ekrano-gx-bpp900480100-297308.jpg?v=1789115671"},{"product_id":"victron-lynx-shunt-cnn-fuse-325a-80v","title":"Victron Fuse CNN 325A\/80V for Lynx shunt (1 pc) - CIP140325000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eFuse CNN 325A\/80V for Victron Lynx Shunt (1 pc)\u003c\/h1\u003e\n\n\u003cp\u003eThis is the OEM replacement CNN fuse rated at 325A and 80V DC, designed specifically for use with the Victron Lynx Shunt. It provides overcurrent protection within the Lynx busbar system and is a direct fit for the Lynx Shunt fuse holder. Suitable for professional installers maintaining or commissioning Victron Lynx-based battery systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 325A continuous current and 80V DC, matched to the Lynx Shunt specification.\u003c\/li\u003e\n  \u003cli\u003eCNN fuse format, designed for direct installation into the Victron Lynx Shunt fuse holder.\u003c\/li\u003e\n  \u003cli\u003eProvides overcurrent protection for the DC busbar and connected battery circuits.\u003c\/li\u003e\n  \u003cli\u003eOEM Victron Energy part, ensuring correct fit and electrical rating without modification.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a single fuse (1 pc), suitable for replacement or commissioning stock.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 58g, compact for storage as a spare on-site or in a service kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Lynx Shunt is a current measurement and fuse module within the Victron Lynx busbar system. The CNN 325A\/80V fuse sits inside the Lynx Shunt and protects the DC circuit from overcurrent events. Using the correct OEM fuse ensures the protection threshold is accurate and that the fuse physically seats correctly in the holder without risk of arcing or poor contact.\u003c\/p\u003e\n\n\u003cp\u003eA blown or degraded fuse in the Lynx Shunt will disable current measurement and interrupt the DC circuit. Keeping a spare on hand is standard practice for any installation using the Lynx Shunt, particularly in off-grid, marine or vehicle systems where access for sourcing parts may be limited. This fuse is the correct replacement part as specified by Victron Energy.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP140325000\u003c\/li\u003e\n  \u003cli\u003eFuse type: CNN\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 325A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 80V DC\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Victron Lynx Shunt\u003c\/li\u003e\n  \u003cli\u003eQuantity: 1 piece\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.058 kg (58g)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021940\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReplacement fuse for Victron Lynx Shunt installations in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eSpare part stocking for marine and narrowboat DC electrical systems using the Lynx busbar.\u003c\/li\u003e\n  \u003cli\u003eCommissioning and maintenance of vehicle or motorhome battery systems built around the Victron Lynx platform.\u003c\/li\u003e\n  \u003cli\u003eService and repair work on existing Lynx Shunt installations where the fuse has blown or requires scheduled replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x CNN 325A\/80V fuse for Victron Lynx Shunt\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eAlways isolate the DC circuit fully before replacing the fuse in a Lynx Shunt. Work on live DC busbars at these current ratings carries a serious risk of arc flash and injury. This replacement should be carried out by a qualified electrician or experienced installer familiar with DC battery systems. Confirm the fault condition that caused the original fuse to blow before fitting a replacement, as fitting a new fuse into a persisting fault will result in immediate failure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632496099619,"sku":"CIP140325000","price":49.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/fuse-cnn-325a80v-for-lynx-shunt-1-pc-cip140325000-853843.jpg?v=1789115345"},{"product_id":"victron-6-way-mega-fuse-holder-cip050060000","title":"Victron Fuse holder 6-way for MEGA-fuse - CIP050060000","description":"\u003ch1 style=\"color: #f87c24;\"\u003e6-Way MEGA Fuse Holder — CIP050060000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy 6-way MEGA fuse holder is a dedicated busbar-style fuse distribution block designed to accept up to six MEGA-fuses. It is suited to 12V, 24V and 48V DC systems where multiple circuits need individual overcurrent protection from a single point, such as battery banks, inverter installations and off-grid distribution boards.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccepts six MEGA-fuses, allowing up to six individually protected DC circuits from one block.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for MEGA-fuse format, ensuring a secure, low-resistance connection at each fuse position.\u003c\/li\u003e\n  \u003cli\u003eCompact, single-unit construction simplifies wiring and reduces the number of individual fuse holders required.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron Energy MEGA-fuse range, maintaining system integrity across Victron installations.\u003c\/li\u003e\n  \u003cli\u003eWeight of 0.53 kg indicates a solid, substantial build suitable for permanent panel or enclosure mounting.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use in battery systems, inverter output distribution, and multi-circuit DC load centres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC protection, commonly used on the battery terminals of inverters, motor drives and large DC loads. Grouping multiple MEGA-fuse positions into a single 6-way holder keeps installations tidy and makes it straightforward to assign a dedicated fuse to each circuit without running separate holders throughout the enclosure.\u003c\/p\u003e\n\n\u003cp\u003eThe 6-way format is particularly useful in off-grid and marine installations where a battery bank feeds several loads simultaneously. Each circuit, whether it is an inverter, a DC distribution rail, a charger or an auxiliary load, can be individually protected and isolated by removing its fuse without disturbing the rest of the system. This approach also simplifies fault-finding and maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP050060000\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076051350\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA-fuse\u003c\/li\u003e\n  \u003cli\u003eNumber of fuse positions: 6\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.53 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMulti-circuit DC distribution in off-grid solar systems\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection and circuit distribution in marine and motorhome installations\u003c\/li\u003e\n  \u003cli\u003eInverter and charger installations requiring individual circuit overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC load centres in commercial and industrial off-grid systems\u003c\/li\u003e\n  \u003cli\u003eCentralised fuse management in 12V, 24V or 48V battery systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy 6-way MEGA fuse holder (CIP050060000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are not included and must be sourced separately, sized appropriately for each circuit. Ensure all connections are torqued to the manufacturer's specification to avoid resistance heating at high currents. Installation in high-current DC systems should be carried out by a qualified electrician or accredited installer familiar with battery system wiring. Always disconnect the battery bank before working on fuse holders or busbars.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632496460067,"sku":"CIP050060000","price":29.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/fuse-holder-6-way-for-mega-fuse-cip050060000-159394.jpg?v=1789115339"},{"product_id":"gx-touch-70-wall-mount","title":"Victron GX Touch 70 Wall Mount - BPP900465070","description":"\u003ch1 style=\"color: #f87c24;\"\u003eGX Touch 70 Wall Mount\u003c\/h1\u003e\n\n\u003cp\u003eThe GX Touch 70 Wall Mount is a dedicated mounting bracket for the Victron GX Touch 70 display, allowing the unit to be fixed directly to a wall or panel surface rather than attached to a Victron GX device. It is suited to installations where the display needs to be positioned independently for easier viewing or access.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned specifically for the Victron GX Touch 70 display unit.\u003c\/li\u003e\n  \u003cli\u003eAllows wall or surface mounting independent of the GX device itself.\u003c\/li\u003e\n  \u003cli\u003eLightweight construction at 0.15 kg, adding minimal load to the mounting surface.\u003c\/li\u003e\n  \u003cli\u003eProvides a fixed, stable position for the touchscreen in control rooms, plant rooms or enclosures.\u003c\/li\u003e\n  \u003cli\u003eSimple bracket design keeps installation straightforward for qualified installers.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the GX Touch 70 (SKU: BPP900465070, GTIN: 8719076054368).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIn many installations, mounting the GX Touch 70 directly onto a Cerbo GX or similar device is not practical. The display may need to be positioned at eye level, inside a dedicated control panel, or at a distance from the main GX unit. This wall mount bracket solves that problem by providing a secure, fixed mounting point on any flat surface.\u003c\/p\u003e\n\n\u003cp\u003eThe bracket is a factory accessory from Victron Energy, so it is designed to fit the GX Touch 70 precisely without modification. The low weight of the assembly means it can be fixed to standard wall surfaces without specialist fixings in most cases, though the installer should always assess the substrate and use appropriate fixings for the environment.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPP900465070\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076054368\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.15 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible display: GX Touch 70\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWall mounting the GX Touch 70 in residential solar and battery storage installations.\u003c\/li\u003e\n  \u003cli\u003eFixed panel display in off-grid cabins, boats and motorhomes where the GX device is located remotely.\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial energy storage systems requiring a dedicated monitoring display position.\u003c\/li\u003e\n  \u003cli\u003eControl room or plant room installations where the touchscreen must be accessible independently of the inverter or GX unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x GX Touch 70 Wall Mount bracket\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis bracket should be installed by a qualified electrician or system integrator familiar with Victron GX installations. Ensure the mounting surface is suitable for the weight of the GX Touch 70 and bracket combined. Use fixings appropriate to the wall or panel material. The GX Touch 70 display and its connecting cable are not included and must be sourced separately.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632502554915,"sku":"BPP900465070","price":16.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/BPP900465050_BPP900465070_8.webp?v=1789115641"},{"product_id":"victron-globallink-520-cellular-monitoring","title":"Victron GlobalLink 520 - ASS030543020","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy GlobalLink 520\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron GlobalLink 520 is a cellular monitoring device that connects Victron installations to the VRM Online Portal over a 2G\/3G\/4G mobile network, without requiring a local internet connection or GX device. It is designed for off-grid, marine and remote installations where a fixed broadband connection is not available or practical.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnects directly to the VRM Online Portal via built-in cellular modem, no GX device or router required.\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of Victron products including MPPT solar charge controllers, BMV battery monitors and Phoenix inverters via VE.Direct.\u003c\/li\u003e\n  \u003cli\u003eSupports up to three VE.Direct connected devices simultaneously.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in global SIM card with data included, covering a broad range of countries without additional SIM management.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 104 g, suitable for installation in space-constrained enclosures.\u003c\/li\u003e\n  \u003cli\u003eProvides remote monitoring, data logging and alert notifications through the VRM portal.\u003c\/li\u003e\n  \u003cli\u003ePowered directly from the VE.Direct port, minimising additional wiring requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GlobalLink 520 addresses a common challenge in remote and off-grid installations: how to monitor system performance without a local network. By using a built-in cellular modem and a pre-provisioned global SIM, the device sends data from connected Victron equipment directly to the VRM Online Portal. Installers and system owners can view live data, historical trends and receive alarm notifications from any internet-connected device.\u003c\/p\u003e\n\n\u003cp\u003eUp to three VE.Direct devices can be connected simultaneously, making it suitable for typical small-to-medium off-grid setups combining an MPPT charge controller, a BMV battery monitor and a Phoenix inverter. The unit draws power from the VE.Direct bus, so no separate power supply is needed in most configurations. This keeps the installation straightforward and reduces the number of connections required inside the enclosure.\u003c\/p\u003e\n\n\u003cp\u003eData is transmitted at regular intervals to the VRM portal, where it is stored and accessible remotely. The portal supports configurable alarms, so operators can be notified by email or push notification if a system parameter moves outside acceptable limits. This is particularly useful for unattended installations such as telecoms cabinets, agricultural pumping systems or remote holiday properties.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: ASS030543020\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076053644\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.104 kg\u003c\/li\u003e\n  \u003cli\u003eConnectivity: VE.Direct (up to 3 ports)\u003c\/li\u003e\n  \u003cli\u003eCommunication: Built-in cellular modem (global SIM included)\u003c\/li\u003e\n  \u003cli\u003ePortal: Victron VRM Online Portal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote off-grid cabins, lodges and holiday properties without fixed broadband.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations requiring remote system monitoring.\u003c\/li\u003e\n  \u003cli\u003eAgricultural and rural sites with solar and battery backup systems.\u003c\/li\u003e\n  \u003cli\u003eTelecoms and infrastructure cabinets with Victron backup power.\u003c\/li\u003e\n  \u003cli\u003eMobile and vehicle-based power systems where a fixed network is unavailable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron GlobalLink 520 unit\u003c\/li\u003e\n  \u003cli\u003ePre-provisioned global SIM card (built-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe GlobalLink 520 connects via standard VE.Direct cables (sold separately) to compatible Victron devices. Installation should be carried out by a qualified electrician or experienced solar installer familiar with Victron systems. Ensure the cellular antenna has adequate signal at the installation location before commissioning. The device requires an active cellular signal to transmit data; performance in areas with very poor mobile coverage cannot be guaranteed. No G98 or G99 grid connection compliance is required for this monitoring accessory.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632503243043,"sku":"ASS030543020","price":203.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/globallink-520-ass030543020-977213.jpg?v=1789115608"},{"product_id":"victron-mk3-usb-interface-ve-bus-ass030140000","title":"Victron Interface MK3-USB (VE.Bus to USB) - ASS030140000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMK3-USB Interface (VE.Bus to USB) — ASS030140000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MK3-USB interface connects a PC or laptop directly to the VE.Bus port on compatible Victron inverters and inverter\/chargers. It allows configuration, monitoring and firmware updates using VEConfigure and VEFlash software on Windows. This is an essential tool for installers commissioning or servicing Victron MultiPlus, MultiGrid and Quattro systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConverts VE.Bus communication to USB, enabling direct PC connection to Victron inverters and inverter\/chargers.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron MultiPlus, MultiPlus-II, MultiGrid and Quattro product ranges.\u003c\/li\u003e\n  \u003cli\u003eSupports configuration via VEConfigure software and firmware updates via VEFlash on Windows.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.08 kg, suitable for carrying in an installer's toolkit.\u003c\/li\u003e\n  \u003cli\u003ePlug-and-play USB connection with no external power supply required from the PC side.\u003c\/li\u003e\n  \u003cli\u003eSKU ASS030140000, GTIN 8719076019435 — genuine Victron Energy product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MK3-USB interface is the standard tool for accessing the VE.Bus communication port found on Victron MultiPlus, MultiPlus-II, MultiGrid and Quattro inverter\/chargers. Without this interface, the internal settings of these units (charge algorithms, input current limits, transfer switch behaviour and system configuration) cannot be adjusted from a PC. It is a required item for any installer working with these products.\u003c\/p\u003e\n\n\u003cp\u003eVEConfigure, the primary configuration tool for VE.Bus devices, only communicates via MK3-USB. The same applies to VEFlash, which is used to update device firmware. Both applications run on Windows. The interface draws its operating power from the connected Victron device rather than the USB port, so no additional power source is needed on the PC side.\u003c\/p\u003e\n\n\u003cp\u003eThis interface does not provide real-time monitoring or data logging. For live system monitoring, a GX device or a VE.Bus Smart Dongle is the appropriate solution. The MK3-USB is specifically a configuration and firmware tool.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: ASS030140000\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076019435\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.08 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: VE.Bus (RJ45) to USB Type-A\u003c\/li\u003e\n  \u003cli\u003eCompatible software: VEConfigure, VEFlash (Windows)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommissioning and configuring Victron MultiPlus, MultiPlus-II, MultiGrid and Quattro inverter\/chargers on site.\u003c\/li\u003e\n  \u003cli\u003eUpdating firmware on VE.Bus devices using VEFlash.\u003c\/li\u003e\n  \u003cli\u003eAdjusting charge settings, input current limits and transfer switch parameters via VEConfigure.\u003c\/li\u003e\n  \u003cli\u003eDiagnosing and reconfiguring existing installations during service visits.\u003c\/li\u003e\n  \u003cli\u003eSetting up parallel and three-phase MultiPlus or Quattro systems that require PC-based configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MK3-USB interface (VE.Bus to USB)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MK3-USB interface is a configuration accessory and does not carry mains or battery voltage. It connects between the RJ45 VE.Bus port on the Victron device and a USB port on a Windows PC. Configuration of inverter\/charger settings, particularly in grid-connected or parallel systems, should be carried out by a qualified installer familiar with Victron VEConfigure. Incorrect configuration of grid-tied systems may affect G98 or G99 compliance. Always verify system settings against the relevant network operator requirements after making changes.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632510877987,"sku":"ASS030140000","price":64.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/interface-mk3-usb-vebus-to-usb-ass030140000-428259.jpg?v=1789115566"},{"product_id":"victron-mega-fuse-500a-32v-pack-5","title":"Victron MEGA-fuse 500A\/32V (package of 5 pcs) - CIP136500010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 500A\/32V (Pack of 5) — CIP136500010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 500A\/32V is a high-current blade-style fuse rated for 32V DC systems. Sold in packs of five, it is designed for use in battery protection circuits, inverter installations and other high-current DC applications where reliable overcurrent protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A current rating suitable for high-current DC battery and inverter circuits.\u003c\/li\u003e\n  \u003cli\u003e32V DC voltage rating, compatible with 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format, designed to fit standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fuses, providing spares for commissioning, maintenance or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, lightweight design at 0.05 kg per pack, easy to store and transport on site.\u003c\/li\u003e\n  \u003cli\u003eProvides short-circuit and overcurrent protection for cables, inverters and battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a widely used format in automotive, marine and solar DC installations. The 500A rating makes this fuse appropriate for large inverter installations, typically those in the 3000W to 5000W range on 12V systems, or higher-capacity 24V systems. The 32V maximum voltage rating covers both 12V and 24V nominal battery banks, including those with elevated charging voltages.\u003c\/p\u003e\n\n\u003cp\u003eThe fuse is installed between the battery positive terminal and the main DC load or inverter input, protecting the wiring and connected equipment in the event of a short circuit or sustained overload. Using the correct fuse rating for the cable cross-section and load is essential. A 500A fuse should be paired with appropriately rated cable, typically 95mm² or larger depending on run length and installation conditions.\u003c\/p\u003e\n\n\u003cp\u003ePurchasing in a pack of five is practical for installers who work across multiple sites or who want to keep a spare on hand after commissioning. MEGA-fuses are consumable components and should be replaced after any fault event, never re-used.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP136500010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 500A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 fuses\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.05 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016670\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection for Victron and third-party inverters on 12V or 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank protection in off-grid solar installations.\u003c\/li\u003e\n  \u003cli\u003eMarine DC systems requiring high-current fuse protection.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome leisure battery circuits with high-draw loads.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x MEGA-fuse 500A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses must be installed in a compatible MEGA fuseholder rated for the current and voltage in use. The fuse should be positioned as close to the battery positive terminal as practicable to maximise protection of the wiring. Ensure the cable rating matches or exceeds the fuse rating. For inverter and battery installations in solar PV systems, installation by a qualified electrician is recommended. Do not exceed the 32V DC voltage rating of this fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632520872227,"sku":"CIP136500010","price":16.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/mega-fuse-500a32v-package-of-5-pcs-cip136500010-736881.jpg?v=1789115326"},{"product_id":"victron-mega-fuse-400a-32v-pack-5","title":"Victron MEGA-fuse 400A\/32V (package of 5 pcs) - CIP136400010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 400A\/32V (Pack of 5) — CIP136400010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse 400A\/32V is a high-current blade-style fuse rated for 32V DC systems, supplied in a pack of five. It is designed for use in battery protection circuits, inverter installations and other high-current DC applications where reliable overcurrent protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e400A current rating suitable for high-current DC battery and inverter circuits.\u003c\/li\u003e\n  \u003cli\u003e32V DC voltage rating, compatible with 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eMEGA blade fuse format, compatible with standard MEGA fuseholders including Victron's own range.\u003c\/li\u003e\n  \u003cli\u003eSupplied as a pack of 5, providing spares for commissioning, servicing or multi-circuit installations.\u003c\/li\u003e\n  \u003cli\u003eCompact, low-profile design allows installation in tight cable runs and battery enclosures.\u003c\/li\u003e\n  \u003cli\u003eSKU CIP136400010, GTIN 8719076016663 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses are a widely used format in DC power systems, particularly for protecting the main cable between a battery bank and an inverter or distribution board. At 400A, this fuse is suited to large inverter installations where cable protection at the battery terminal is a regulatory and practical requirement. The 32V rating covers both 12V and 24V nominal battery systems, which are the most common voltages in marine, vehicle and off-grid solar installations.\u003c\/p\u003e\n\n\u003cp\u003eThe MEGA fuse format uses a bolted connection rather than a push-fit blade, which provides a lower-resistance joint and greater mechanical stability under vibration. This makes it appropriate for mobile applications such as motorhomes, boats and commercial vehicles, as well as static off-grid systems. Fuses in this format are consumed items: they should be replaced after any fault event, and having spares on site is standard practice for professional installers.\u003c\/p\u003e\n\n\u003cp\u003eThis fuse is compatible with Victron MEGA fuseholders (sold separately). Always verify that the fuseholder is rated for the current and voltage of the application before installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP136400010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 400A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 32V DC\u003c\/li\u003e\n  \u003cli\u003eFuse type: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 5 pieces\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.05 kg (per pack)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016663\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain battery fuse protection for 12V and 24V inverter installations.\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection on battery-to-busbar connections in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eMarine DC distribution boards and battery protection circuits.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, campervan and commercial vehicle power systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement fuses for existing MEGA fuseholder installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 x Victron Energy MEGA-fuse 400A\/32V\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMEGA fuses must be installed in a compatible MEGA fuseholder rated for the application voltage and current. The fuse should be positioned as close to the battery positive terminal as practicable to provide effective short-circuit protection for the full cable run. Ensure the fuseholder connections are torqued to the manufacturer's specification to avoid resistance heating at the joint. For inverter and battery installations forming part of a solar PV system, installation by a qualified electrician is recommended. Always isolate the battery before replacing a fuse.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632520904995,"sku":"CIP136400010","price":16.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/mega-fuse-400a32v-package-of-5-pcs-cip136400010-492549.jpg?v=1789115320"},{"product_id":"victron-mega-fuse-250a-58v-48v","title":"Victron MEGA-fuse 250A\/58V-48Vprod(1 pc) *If 0, order CIP138250020* - CIP137250010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eMEGA-Fuse 250A\/58V for 48V Systems (1 pc) — CIP137250010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MEGA-Fuse 250A\/58V is a high-current blade-style fuse designed for overcurrent protection in 48V battery systems. It is used in conjunction with a compatible MEGA fuseholder and is suited to DC circuits in solar, off-grid and marine installations where reliable, rated protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 250A continuous current with a maximum voltage of 58V DC, making it appropriate for 48V nominal battery banks.\u003c\/li\u003e\n  \u003cli\u003eMEGA-fuse format provides a compact, bolt-down connection suitable for high-current DC applications.\u003c\/li\u003e\n  \u003cli\u003eSingle fuse per pack (1 pc), allowing replacement or single-circuit installation without purchasing unnecessary spares.\u003c\/li\u003e\n  \u003cli\u003eVictron part number CIP137250010, compatible with Victron MEGA fuseholders designed for this fuse format.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 9 grams, with a GTIN of 8719076016700 for straightforward procurement and stock management.\u003c\/li\u003e\n  \u003cli\u003eProvides a sacrificial protection point in DC wiring, helping to protect inverters, battery monitors and other connected equipment from overcurrent damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMEGA-fuses are a standard format for high-current DC protection in battery-based systems. The 250A rating is commonly used on the main DC feed between a 48V battery bank and an inverter or inverter\/charger, where cable runs and equipment ratings demand a clearly defined fault current limit. The 58V maximum voltage rating gives adequate headroom above the typical maximum charge voltage of a 48V lithium or lead-acid battery bank.\u003c\/p\u003e\n\n\u003cp\u003eThis fuse must be installed in a compatible MEGA fuseholder. If the CIP137250010 shows zero stock, Victron recommends ordering CIP138250020 as the alternative. Always verify the fuseholder model is rated for the same voltage and current before installation. The fuse itself is a consumable item and should be replaced like-for-like after any overcurrent event.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP137250010\u003c\/li\u003e\n  \u003cli\u003eCurrent rating: 250A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 58V DC (for 48V nominal systems)\u003c\/li\u003e\n  \u003cli\u003eFuse format: MEGA blade fuse\u003c\/li\u003e\n  \u003cli\u003ePack quantity: 1 piece\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.009 kg (9 g)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076016700\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMain DC overcurrent protection between a 48V battery bank and a Victron MultiPlus or Quattro inverter\/charger.\u003c\/li\u003e\n  \u003cli\u003eFuse replacement in existing MEGA fuseholder installations following an overcurrent event.\u003c\/li\u003e\n  \u003cli\u003eOff-grid solar systems with 48V battery storage requiring a rated DC protection point.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle DC systems operating at 48V nominal voltage.\u003c\/li\u003e\n  \u003cli\u003eAny DC circuit where a MEGA-format fuse at 250A\/58V is specified by the system designer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MEGA-Fuse 250A\/58V (CIP137250010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis fuse must be fitted in a correctly rated MEGA fuseholder. Ensure the fuseholder is rated for at least 58V DC and 250A before installation. DC wiring at this current level carries significant fault energy and should be installed by a qualified electrician or accredited installer familiar with battery-based DC systems. Always isolate the battery bank before replacing or installing fuses. Do not substitute with a fuse of a higher current rating, as this will defeat the purpose of overcurrent protection.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632521101603,"sku":"CIP137250010","price":28.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/mega-fuse-250a58v-for-48v-products-1-pc-cip137250010-618623.jpg?v=1789115333"},{"product_id":"victron-mppt-control-remote-display-panel","title":"Victron MPPT Control - SCC900500000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MPPT Control Remote Display Panel — SCC900500000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MPPT Control is a dedicated remote display and control panel for Victron BlueSolar and SmartSolar MPPT charge controllers. It connects via the VE.Direct port and gives installers and system operators a clear, real-time view of charge status, battery voltage, solar input and load output without needing a phone, laptop or VRM portal access.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnects directly to Victron MPPT charge controllers via the VE.Direct port, no additional interface required.\u003c\/li\u003e\n  \u003cli\u003eDisplays real-time data including battery voltage, charge current, solar panel voltage and charge state.\u003c\/li\u003e\n  \u003cli\u003eAllows remote on\/off control of the connected MPPT charge controller from the panel.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 65 g, suitable for flush or surface mounting in a control cabinet or enclosure.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the full range of Victron BlueSolar and SmartSolar MPPT charge controllers that feature a VE.Direct port.\u003c\/li\u003e\n  \u003cli\u003eSimple plug-and-play connection using the VE.Direct cable (sold separately), with no configuration software needed for basic operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MPPT Control panel is designed for installations where a permanent, wall-mounted display is more practical than a mobile device or laptop. It is particularly useful in off-grid cabins, marine installations, vehicle conversions and remote telecoms or monitoring sites where the system owner or operator needs quick access to charge controller data at a glance.\u003c\/p\u003e\n\n\u003cp\u003eThe panel communicates over VE.Direct, Victron's dedicated low-level serial protocol used across their MPPT range. This means the display receives accurate, live data directly from the charge controller rather than via a network or cloud service. The remote on\/off function is a practical addition for systems where the charge controller is mounted in an inaccessible location, such as inside a sealed enclosure or behind a panel.\u003c\/p\u003e\n\n\u003cp\u003eNote that the MPPT Control requires a VE.Direct cable to connect to the charge controller. This cable is not included in the box and must be ordered separately. Check the VE.Direct port availability on your specific MPPT model before ordering, as some controllers have only one VE.Direct port which may already be in use.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SCC900500000\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.065 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: VE.Direct port\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076025641\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar installations in cabins, outbuildings or remote sites requiring a fixed local display.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat solar systems where a panel-mounted display is preferred over a mobile app.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome conversions with a dedicated 12 V or 24 V solar charging system.\u003c\/li\u003e\n  \u003cli\u003eTelecoms and remote monitoring enclosures where quick visual status checks are needed without network access.\u003c\/li\u003e\n  \u003cli\u003eAny installation where the MPPT charge controller is mounted out of direct sight or in a sealed enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MPPT Control display panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MPPT Control connects to the VE.Direct port on a compatible Victron MPPT charge controller. A VE.Direct cable is required and is not supplied in the box. Ensure the charge controller is powered down before making or removing connections. Installation within a solar PV system should be carried out by a qualified electrician or MCS-accredited installer. Do not expose the panel to direct moisture or install outside of a suitable enclosure.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632525263139,"sku":"SCC900500000","price":48.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/mppt-control-scc900500000-882555.jpg?v=1789115596"},{"product_id":"victron-rs485-to-usb-interface-cable-5m","title":"Victron RS485 to USB interface 5m - ASS030572050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eRS485 to USB Interface Cable 5m — ASS030572050\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron RS485 to USB interface cable provides a direct serial communication link between RS485-enabled Victron devices and a PC or laptop via USB. At 5 metres in length, it gives installers enough reach to connect equipment in panels or enclosures without needing to position a laptop directly alongside the unit. It is used primarily for configuration, monitoring and firmware updates on compatible Victron products.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5 metre cable length provides practical reach in installation environments without signal degradation.\u003c\/li\u003e\n  \u003cli\u003eConverts RS485 serial signals to USB for connection to any standard PC or laptop.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron devices that use an RS485 communication port, including select MPPT solar chargers and inverters.\u003c\/li\u003e\n  \u003cli\u003ePlug-and-play USB connection; no external power supply required as the interface draws power from the USB host.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use with VictronConnect or other Victron configuration software on Windows, macOS and Linux where drivers are supported.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 187g, making it easy to carry as part of a standard installer toolkit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\n\u003cp\u003eRS485 is a differential serial communication standard commonly used in industrial and energy equipment for its noise immunity over longer cable runs. Victron uses RS485 ports on certain products to allow direct wired communication for configuration and diagnostics. This interface cable bridges that RS485 port to a standard USB-A connection, making it accessible from any modern computer without requiring a dedicated serial port.\u003c\/p\u003e\n\n\u003cp\u003eThe 5m cable length is a practical choice for real-world installation scenarios where the inverter, charger or other device is mounted in a cabinet or on a wall at a distance from the technician's workstation. The built-in conversion electronics are housed within the cable assembly, keeping the setup simple. Driver installation may be required on some operating systems; check Victron's software documentation for your specific OS before use.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: ASS030572050\u003c\/li\u003e\n  \u003cli\u003eCable length: 5 metres\u003c\/li\u003e\n  \u003cli\u003eInterface: RS485 to USB\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.187 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076040088\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfiguring and updating firmware on Victron RS485-equipped devices in the field.\u003c\/li\u003e\n  \u003cli\u003eMonitoring and diagnostics on off-grid and marine installations where RS485 communication is used.\u003c\/li\u003e\n  \u003cli\u003eConnecting to Victron MPPT solar chargers or inverters with RS485 ports from a laptop during commissioning.\u003c\/li\u003e\n  \u003cli\u003eWorkshop bench testing and pre-configuration of Victron equipment before site installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x RS485 to USB interface cable, 5m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis cable is a passive communication accessory and does not carry mains or high-voltage DC power. No specialist electrical qualification is required to connect it between a Victron device and a PC. Ensure the correct driver is installed on your computer before use. Always follow Victron's guidance when updating firmware on live systems, and confirm the device is in a safe state before making configuration changes.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632538632483,"sku":"ASS030572050","price":30.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/RS485_to_USB_interface_cable_5_m.jpg?v=1789115760"},{"product_id":"victron-rj45-utp-cable-0-9m-ass030064920","title":"Victron RJ45 UTP Cable 0,9 m *If 0, order ASS030064921* - ASS030064920","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy RJ45 UTP Cable 0.9 m — ASS030064920\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy RJ45 UTP Cable (0.9 m) is a short-run data cable used to connect compatible Victron devices via RJ45 ports. It is suited to installers who need a reliable, correctly terminated cable for communications between Victron components in a compact installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e0.9 m cable length, suitable for connecting devices mounted in close proximity within a panel or enclosure.\u003c\/li\u003e\n  \u003cli\u003eStandard RJ45 connectors on both ends, compatible with Victron devices that use UTP data connections.\u003c\/li\u003e\n  \u003cli\u003eUTP (Unshielded Twisted Pair) construction for reliable low-voltage data communication.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 37 g, adding minimal bulk to an installation.\u003c\/li\u003e\n  \u003cli\u003eVictron OEM part, ensuring correct pinout and compatibility with supported Victron equipment.\u003c\/li\u003e\n  \u003cli\u003eSKU ASS030064920. If stock shows zero, order ASS030064921 as the equivalent replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThis cable is used in Victron Energy systems where RJ45 data connections are required between devices such as inverter\/chargers, battery monitors, display panels and other compatible components. The 0.9 m length is intended for short-distance connections, typically within the same cabinet or wall-mounted installation area.\u003c\/p\u003e\n\n\u003cp\u003eUsing a Victron-supplied cable ensures the correct wiring configuration for the RJ45 interface. Third-party cables may use different pin assignments and can cause communication errors or device faults. For longer cable runs, Victron offers alternative lengths in the same cable series.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: ASS030064920\u003c\/li\u003e\n  \u003cli\u003eCable length: 0.9 m\u003c\/li\u003e\n  \u003cli\u003eConnector type: RJ45 (both ends)\u003c\/li\u003e\n  \u003cli\u003eCable type: UTP (Unshielded Twisted Pair)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.037 kg (37 g)\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076019206\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting Victron inverter\/chargers to compatible display or control panels.\u003c\/li\u003e\n  \u003cli\u003eData communication between Victron battery monitors and system components.\u003c\/li\u003e\n  \u003cli\u003eShort-run RJ45 connections within off-grid, marine or vehicle power systems.\u003c\/li\u003e\n  \u003cli\u003eReplacement or spare cable for existing Victron installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy RJ45 UTP Cable, 0.9 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis cable carries data signals only and does not carry mains or high-voltage power. Connection is straightforward for qualified installers familiar with Victron system wiring. Ensure the correct devices are being connected before use, as RJ45 ports on Victron equipment are not always interchangeable. If this SKU shows as unavailable, order ASS030064921 as the direct alternative.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632538763555,"sku":"ASS030064920","price":8.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-rj45-utp-cable-09-m-ass030064920-502799.jpg?v=1789115695"},{"product_id":"victron-smartsolar-pluggable-display-scc900650010","title":"Victron SmartSolar Pluggable Display - SCC900650010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartSolar Pluggable Display — SCC900650010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartSolar Pluggable Display is an optional add-on screen for compatible Victron SmartSolar MPPT charge controllers. It gives installers and system owners a direct, at-a-glance view of charge status and key system data without needing a phone, tablet or laptop. It is aimed at off-grid installations, marine systems and any site where a permanent local display is more practical than a Bluetooth connection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlugs directly into compatible Victron SmartSolar MPPT charge controllers with no additional wiring required.\u003c\/li\u003e\n  \u003cli\u003eDisplays real-time data including battery voltage, charge current, solar input power and charge state.\u003c\/li\u003e\n  \u003cli\u003eCompact, lightweight design at 0.08 kg, suitable for panel-mounted or enclosure-mounted controllers.\u003c\/li\u003e\n  \u003cli\u003eProvides a local readout independent of Bluetooth or VictronConnect app connectivity.\u003c\/li\u003e\n  \u003cli\u003eDesigned for permanent installation, giving continuous visibility of system performance.\u003c\/li\u003e\n  \u003cli\u003eSupplied by Victron Energy, a manufacturer with a well-established track record in solar charge control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eMany SmartSolar MPPT controllers are installed in locations where pulling out a phone to check system status is inconvenient, such as a battery compartment, a plant room or a remote off-grid cabin. The pluggable display solves this by providing a fixed local interface that shows the information you need the moment you look at the controller.\u003c\/p\u003e\n\n\u003cp\u003eThe display connects via the dedicated port on compatible SmartSolar MPPT units. No separate power supply or data cable is needed. Once fitted, it draws its power and data directly from the controller. This keeps the installation clean and avoids any additional wiring complexity in what is often already a busy enclosure.\u003c\/p\u003e\n\n\u003cp\u003eIt is worth confirming compatibility with the specific SmartSolar MPPT model before ordering. The display is designed for the SmartSolar MPPT range and is not compatible with BlueSolar or other Victron controller series.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: SCC900650010\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076043546\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.08 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible product range: Victron SmartSolar MPPT charge controllers (selected models with display port)\u003c\/li\u003e\n  \u003cli\u003eConnection: Pluggable, direct to controller display port\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar installations where remote monitoring via app is not always practical.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat systems requiring a permanent, readable charge status display.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle-based solar setups where quick visual checks are preferred.\u003c\/li\u003e\n  \u003cli\u003eCommercial or agricultural off-grid sites with multiple controllers needing local status indication.\u003c\/li\u003e\n  \u003cli\u003eAny SmartSolar MPPT installation where the owner or operator is not comfortable using the VictronConnect app.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron SmartSolar Pluggable Display (SCC900650010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe display plugs directly into the display port on compatible SmartSolar MPPT controllers. Verify that your specific controller model includes a display port before purchasing, as not all SmartSolar MPPT variants support this accessory. Installation is straightforward and does not require a qualified electrician, but any work on the wider solar or battery system should be carried out by a competent installer familiar with DC electrical systems.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632541090083,"sku":"SCC900650010","price":30.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/smartsolar-pluggable-display-scc900650010-143040.jpg?v=1789115554"},{"product_id":"victron-smartshunt-500a-50mv-ip65","title":"Victron SmartShunt 500A\/50mV IP65 - SHU065150050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartShunt 500A\/50mV IP65 — SHU065150050\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartShunt 500A\/50mV IP65 is a standalone battery monitor designed for professional solar, off-grid and marine installations where accurate state-of-charge data is essential. It connects directly to a smartphone or tablet via Bluetooth, removing the need for a separate display unit. The IP65 rating makes it suitable for installations in damp or dusty environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating with a 50mV shunt drop, suitable for high-capacity battery banks.\u003c\/li\u003e\n  \u003cli\u003eIP65 rated enclosure, providing protection against dust ingress and low-pressure water jets.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth for direct connection to the Victron Connect app on iOS and Android devices.\u003c\/li\u003e\n  \u003cli\u003eMonitors state of charge, voltage, current, power, consumed amp-hours and time remaining.\u003c\/li\u003e\n  \u003cli\u003eConfigurable battery capacity, charge efficiency factor, Peukert exponent and tail current settings to suit lead-acid, AGM, gel and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eRelay output for high or low voltage alarms, state-of-charge alarms or other user-defined triggers.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the Victron VE.Direct ecosystem, allowing integration with GX devices, MPPT controllers and Venus OS installations.\u003c\/li\u003e\n  \u003cli\u003eNo display required on the unit itself, reducing installation complexity and cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt replaces a traditional battery monitor shunt and display combination with a single compact unit. All monitoring and configuration is handled through the Victron Connect app over Bluetooth, which means there is no wiring required for a remote display panel. This is particularly useful in installations where panel space is limited or where the battery bank is located in an awkward position.\u003c\/p\u003e\n\n\u003cp\u003eThe 500A\/50mV rating means the shunt itself produces a 50 millivolt drop at full rated current. This is the standard shunt specification used across most battery monitor designs and is compatible with the measurement circuitry built into the SmartShunt. The IP65 rating distinguishes this variant from the standard SmartShunt: it is housed in a sealed enclosure that resists dust and water ingress, making it appropriate for engine rooms, battery compartments in boats, caravans and outdoor off-grid enclosures where condensation or spray may be present.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Direct port allows the SmartShunt to feed data into a Victron GX device such as a Cerbo GX or Venus GX, making battery state-of-charge visible on a system overview alongside solar yield, inverter load and grid status. This integration is straightforward and requires only a standard VE.Direct cable.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSHU065150050\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eShunt rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e500A \/ 50mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIP rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (Victron Connect app), VE.Direct\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible battery chemistries\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLead-acid, AGM, gel, lithium\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRelay output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (programmable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076057895\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems requiring accurate battery state-of-charge monitoring without a dedicated display panel.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations where IP65 protection is needed against condensation and bilge spray.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, campervan and caravan leisure battery banks monitored via smartphone.\u003c\/li\u003e\n  \u003cli\u003eBattery storage systems integrated with Victron GX devices for whole-system monitoring via Venus OS.\u003c\/li\u003e\n  \u003cli\u003eCommercial off-grid installations where the battery enclosure is remote from any control panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron SmartShunt 500A\/50mV IP65 unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt must be installed in the negative battery cable between the battery negative terminal and all other negative connections in the system. All negative loads and charge sources must return through the shunt for accurate current measurement. Installation in battery systems above 48V or in lithium battery installations should be carried out by a qualified electrician or accredited installer. The VE.Direct port requires a separate cable (not included) for integration with GX devices.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632541384995,"sku":"SHU065150050","price":96.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/smartshunt-500a50mv-ip65-shu065150050-764960.jpg?v=1789115664"},{"product_id":"victron-smartshunt-1000a","title":"Victron SmartShunt 1000A - SHU050210050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartShunt 1000A — SHU050210050\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartShunt 1000A is a standalone battery monitor designed for professional solar, off-grid and marine installations where accurate state-of-charge tracking is essential. It connects directly to a smartphone or tablet via Bluetooth, removing the need for a separate display unit. Suitable for any battery chemistry, it suits installers and system integrators who need reliable monitoring without additional hardware overhead.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1000A continuous current rating, suitable for large battery banks in off-grid, marine and commercial vehicle applications.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth connectivity allows monitoring via the Victron Connect app on iOS and Android without a separate display.\u003c\/li\u003e\n  \u003cli\u003eMonitors state of charge, voltage, current, power, consumed amp-hours, time to go and historical data.\u003c\/li\u003e\n  \u003cli\u003eCompatible with all common battery chemistries including lead-acid (AGM, gel, flooded) and lithium (LiFePO4).\u003c\/li\u003e\n  \u003cli\u003eVE.Direct port enables integration with Victron GX devices, Cerbo GX and the VRM online monitoring portal.\u003c\/li\u003e\n  \u003cli\u003eConfigurable battery parameters including capacity, Peukert exponent, charge efficiency factor and tail current.\u003c\/li\u003e\n  \u003cli\u003eCompact shunt-only form factor: no separate monitor head required, reducing panel space and wiring complexity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt replaces the traditional shunt-plus-display combination by integrating all monitoring electronics directly into the shunt body. All data is transmitted over Bluetooth to the VictronConnect app, which provides a clear dashboard of battery status in real time. This makes it particularly practical in installations where panel space is limited or where a permanent display is unnecessary, such as in battery enclosures, camper van builds or remote off-grid cabinets.\u003c\/p\u003e\n\n\u003cp\u003eThe 1000A rating makes this variant appropriate for larger systems: high-capacity lithium battery banks, parallel battery configurations and heavy-load DC systems in commercial vehicles or vessels. The VE.Direct port means the SmartShunt can feed data directly into a Victron GX device, making it a straightforward addition to any Victron-based system that uses the VRM portal for remote monitoring. Battery parameters are fully configurable, so the monitor can be calibrated accurately to the specific battery bank in use.\u003c\/p\u003e\n\n\u003cp\u003eUnlike a BMV battery monitor, the SmartShunt has no display of its own. If a permanent on-panel readout is required, a BMV-712 or a GX display is the appropriate choice. For installations where app-based or remote monitoring is sufficient, the SmartShunt offers the same measurement accuracy in a smaller, lower-cost package.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSHU050210050\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous current rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1000A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (VictronConnect app) and VE.Direct\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible battery chemistries\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLead-acid (AGM, gel, flooded), LiFePO4 and other lithium\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDisplay\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNone (app-based via VictronConnect)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076044260\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge off-grid solar systems with high-capacity battery banks requiring accurate state-of-charge monitoring.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat DC systems where panel space is limited and app-based monitoring is preferred.\u003c\/li\u003e\n  \u003cli\u003eCommercial vehicle and motorhome leisure battery installations with heavy DC loads.\u003c\/li\u003e\n  \u003cli\u003eVictron-based systems integrated with a Cerbo GX or other GX device for VRM remote monitoring.\u003c\/li\u003e\n  \u003cli\u003eParallel battery bank configurations where total current draw exceeds the range of lower-rated shunts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron SmartShunt 1000A (SHU050210050)\u003c\/li\u003e\n  \u003cli\u003eConnection cable for battery negative and auxiliary input\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt must be installed in the negative battery cable between the battery negative terminal and all other negative connections in the system. All negative loads and charge sources must return through the shunt to ensure accurate current measurement. Installation in high-current DC systems should be carried out by a qualified electrician or experienced system integrator. For marine installations, follow applicable wiring standards for the vessel type. The unit does not require a separate power supply beyond the battery connection itself.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632541450531,"sku":"SHU050210050","price":152.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/smartshunt-1000a50mv-shu050210050-468915.jpg?v=1789115602"},{"product_id":"victron-smartshunt-500a-50mv","title":"Victron SmartShunt 500A\/50mV - SHU050150050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartShunt 500A\/50mV — SHU050150050\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartShunt 500A\/50mV is a standalone battery monitor that measures state of charge, consumed amp hours, and voltage without requiring a dedicated display unit. It connects directly to the VictronConnect app via Bluetooth, making it a practical choice for installers and off-grid system builders who need accurate battery monitoring without the cost or complexity of a full BMV monitor.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e500A continuous current rating with a 50mV shunt drop, suitable for most 12V, 24V and 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth connects to the VictronConnect app on iOS and Android for real-time monitoring and configuration.\u003c\/li\u003e\n  \u003cli\u003eMonitors state of charge (%), consumed amp hours, voltage, current, power, and time remaining.\u003c\/li\u003e\n  \u003cli\u003eSupports a wide range of battery chemistries including lead-acid (AGM, gel, flooded) and lithium (LiFePO4).\u003c\/li\u003e\n  \u003cli\u003eCompact, shunt-only form factor replaces the need for a separate display, reducing installation space and cost.\u003c\/li\u003e\n  \u003cli\u003eConfigurable charge efficiency factor, Peukert exponent, and tail current settings for accurate SoC tracking across different battery types.\u003c\/li\u003e\n  \u003cli\u003eVE.Direct port allows integration with Victron GX devices, MPPT solar charge controllers, and other compatible equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt functions as the measurement core of a battery monitoring system. The 50mV shunt drop at 500A gives the device a precise reference for calculating current flow in and out of the battery. This data is processed internally and transmitted over Bluetooth to VictronConnect, where users can view live readings, review historical data, and adjust monitoring parameters. No separate display unit or control panel is required, though one can be added if needed.\u003c\/p\u003e\n\n\u003cp\u003eThe VE.Direct port is a significant practical advantage. It allows the SmartShunt to feed battery state-of-charge data into a Victron GX device (such as a Cerbo GX), making it visible on the VRM portal and usable by other devices in the system for load shedding or generator start logic. This makes the SmartShunt a cost-effective entry point into a fully integrated Victron monitoring ecosystem.\u003c\/p\u003e\n\n\u003cp\u003eAccurate state-of-charge tracking depends on correct configuration. The SmartShunt allows adjustment of battery capacity, charge efficiency factor, Peukert exponent, and the tail current threshold used to detect a full charge. Taking time to configure these parameters correctly for the specific battery bank will significantly improve the reliability of the SoC reading over time.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSHU050150050\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eShunt rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e500A \/ 50mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (VictronConnect app) + VE.Direct port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible app\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVictronConnect (iOS and Android)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.32 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076044253\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems requiring battery state-of-charge monitoring without a dedicated display panel.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations where panel space is limited and Bluetooth monitoring is preferred.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and campervan leisure battery banks with 12V or 24V systems.\u003c\/li\u003e\n  \u003cli\u003eVictron-based systems using a Cerbo GX or other GX device, where the SmartShunt feeds SoC data via VE.Direct.\u003c\/li\u003e\n  \u003cli\u003eRetrofit monitoring on existing battery banks where a full BMV monitor is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron SmartShunt 500A\/50mV unit\u003c\/li\u003e\n  \u003cli\u003eVE.Direct cable\u003c\/li\u003e\n  \u003cli\u003eConnection cable for battery negative\u003c\/li\u003e\n  \u003cli\u003eDocumentation and quick-start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt must be installed in the negative battery lead, between the battery negative terminal and all other negative connections in the system. All negative return currents must pass through the shunt for accurate measurement. Incorrect wiring, such as bypassing the shunt with a direct chassis ground, will produce inaccurate readings. Installation should be carried out by a qualified electrician or experienced installer familiar with DC battery systems. For systems integrated into a solar PV installation, a qualified or MCS-accredited installer is recommended.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632541483299,"sku":"SHU050150050","price":90.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/smartshunt-500a50mv-shu050150050-688289.jpg?v=1789114584"},{"product_id":"victron-smartshunt-2000a-shu050220050","title":"Victron SmartShunt 2000A - SHU050220050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron SmartShunt 2000A — SHU050220050\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron SmartShunt 2000A is a standalone battery monitor designed for high-current battery systems where accurate state-of-charge tracking is essential. It connects directly to a smartphone or tablet via Bluetooth, removing the need for a separate display unit. Suited to professional off-grid, marine and vehicle installations where large battery banks are in use.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2000A continuous current rating, suitable for large battery banks and high-draw systems.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth connectivity allows monitoring via the Victron Connect app on iOS and Android without additional hardware.\u003c\/li\u003e\n  \u003cli\u003eMeasures state of charge, voltage, current, power, consumed amp-hours, and time remaining.\u003c\/li\u003e\n  \u003cli\u003eNo display unit required — the SmartShunt acts as the monitor itself, keeping installation compact.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the Victron VE.Direct port for integration with GX devices, MPPT controllers and other Victron equipment.\u003c\/li\u003e\n  \u003cli\u003eSupports multiple battery chemistries including lead-acid (AGM, gel, flooded) and lithium (LiFePO4).\u003c\/li\u003e\n  \u003cli\u003eConfigurable alarm and relay outputs for low state-of-charge or voltage threshold alerts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\n\u003cp\u003eThe SmartShunt replaces the traditional shunt-plus-display combination with a single unit. All monitoring data is accessed through the Victron Connect app over Bluetooth, which provides a clear dashboard view of battery status in real time. This approach reduces wiring complexity and eliminates the need to mount a dedicated display panel, which is particularly useful in space-constrained installations such as motorhomes, narrowboats and off-grid cabins.\u003c\/p\u003e\n\n\u003cp\u003eAt 2000A, this is the highest-rated model in the SmartShunt range. It is intended for systems with very large battery banks or high continuous loads, such as electric propulsion assist, large inverter installations or commercial off-grid setups. The VE.Direct port allows the SmartShunt to feed data into a Victron Cerbo GX or other GX device, making it a straightforward addition to a full Victron system. Battery chemistry and capacity parameters are configured in the app, ensuring accurate state-of-charge calculations for the specific battery type in use.\u003c\/p\u003e\n\n\u003cp\u003eThe unit also supports synchronisation with solar charge controllers and other sources, so the state-of-charge reading accounts for all charge and discharge currents entering and leaving the battery. This is important in multi-source systems where accuracy would otherwise be compromised by unmonitored charge paths.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSHU050220050\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous current rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2000A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (Victron Connect app) and VE.Direct\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible battery chemistries\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLead-acid (AGM, gel, flooded), LiFePO4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076044277\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge off-grid battery systems requiring accurate state-of-charge monitoring.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations with high-capacity battery banks.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and coach conversions with significant 12V or 24V loads.\u003c\/li\u003e\n  \u003cli\u003eCommercial off-grid sites with multiple battery strings and high continuous draw.\u003c\/li\u003e\n  \u003cli\u003eVictron system integrations using a Cerbo GX or Venus GX for centralised monitoring.\u003c\/li\u003e\n  \u003cli\u003eElectric vehicle auxiliary battery monitoring where high current measurement is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron SmartShunt 2000A (SHU050220050)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe SmartShunt must be installed by a qualified electrician or experienced system integrator. At 2000A, the unit is intended for high-current DC systems where incorrect wiring presents a serious risk of damage or injury. The shunt must be placed on the negative battery terminal side, with all negative loads and charge sources connected to the load side of the shunt. Ensure cable sizing and fusing are appropriate for the system current. Configuration of battery parameters should be completed in the Victron Connect app before commissioning to ensure accurate monitoring from the outset.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632541548835,"sku":"SHU050220050","price":195.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/smartshunt-2000a50mv-shu050220050-452743.jpg?v=1789115620"},{"product_id":"victron-2m-extension-cable-20a-blue-power-ip65","title":"Victron 2 meter extension cable (max. 20A) - BPC900200014","description":"\u003ch1 style=\"color: #f87c24;\"\u003e2 Metre Extension Cable (Max. 20A) — BPC900200014\u003c\/h1\u003e\n\n\u003cp\u003eThis 2 metre extension cable is designed for use with Victron Blue Power IP65 chargers. It extends the reach of the charger output lead, allowing more flexible positioning of the charger relative to the battery. Rated to a maximum of 20A, it is suited to the full range of Blue Power IP65 charger models.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2 metre cable length provides additional reach between charger and battery terminals.\u003c\/li\u003e\n  \u003cli\u003eMaximum current rating of 20A, compatible with the Blue Power IP65 charger range.\u003c\/li\u003e\n  \u003cli\u003eDesigned as a genuine Victron Energy accessory, ensuring correct connector fit and current rating.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.2 kg, easy to store and carry alongside the charger.\u003c\/li\u003e\n  \u003cli\u003eSKU BPC900200014 — direct replacement or additional accessory for Blue Power IP65 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe standard output lead on a Blue Power IP65 charger may not always reach the battery, particularly in vehicles, boats or installations where the charger must be mounted away from the battery bank. This extension cable connects in-line to add 2 metres of reach without requiring any modification to the charger or wiring.\u003c\/p\u003e\n\n\u003cp\u003eThe 20A maximum current rating matches the output capacity of the larger Blue Power IP65 charger models, so there is no derating or compromise when using this cable at full charger output. Using a genuine Victron accessory ensures the connectors mate correctly and the cable is rated appropriately for the application.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPC900200014\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076040132\u003c\/li\u003e\n  \u003cli\u003eCable length: 2 metres\u003c\/li\u003e\n  \u003cli\u003eMaximum current: 20A\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.2 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible category: Accessories for Blue Power IP65 Chargers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eExtending charger reach in marine and narrowboat installations where the charger is mounted away from the battery bank.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and caravan battery charging where cable routing requires additional length.\u003c\/li\u003e\n  \u003cli\u003eWorkshop or garage charging setups with fixed charger mounting positions.\u003c\/li\u003e\n  \u003cli\u003eAny Blue Power IP65 charger installation where the standard lead is too short to reach the battery terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x 2 metre extension cable (max. 20A) for Blue Power IP65 chargers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure the extension cable is routed and secured to avoid mechanical damage, chafing or contact with heat sources. Confirm the total combined cable run is appropriate for the charger output current and that all connectors are fully seated before use. This accessory is intended for use with Victron Blue Power IP65 chargers only. If you are unsure about the suitability of this cable for your installation, consult a qualified electrician or auto-electrician.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551444771,"sku":"BPC900200014","price":8.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-2-meter-extension-cable-bpc900200014-371172.jpg?v=1789115967"},{"product_id":"victron-batteryprotect-48v-100a","title":"Victron BatteryProtect 48V-100A - BPR048100400","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron BatteryProtect 48V-100A — BPR048100400\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BatteryProtect 48V-100A is an automatic battery disconnect device designed to protect 48V battery banks from over-discharge. It disconnects the load before the battery reaches a critically low voltage, preventing cell damage and extending battery service life. It is suited to off-grid solar systems, marine installations, and any 48V DC application where load shedding is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 100A continuous current on a 48V system, suitable for substantial DC load circuits.\u003c\/li\u003e\n  \u003cli\u003eAutomatic disconnect on low battery voltage with configurable reconnect threshold, protecting cells from deep discharge damage.\u003c\/li\u003e\n  \u003cli\u003eExtremely low self-consumption, minimising parasitic drain on the battery bank when idle.\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input allows integration with battery management systems, inverters or manual switches.\u003c\/li\u003e\n  \u003cli\u003eAlarm output provides a pre-disconnect warning signal, allowing loads or systems to shut down in a controlled manner before isolation occurs.\u003c\/li\u003e\n  \u003cli\u003eCompatible with lithium (LiFePO4) and lead-acid battery chemistries, with voltage thresholds selectable via a rotary switch.\u003c\/li\u003e\n  \u003cli\u003eCompact, lightweight design at 0.8 kg, suitable for panel or DIN rail mounting in enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect works by monitoring battery voltage continuously. When voltage drops to the programmed disconnect threshold, the unit opens the load circuit and holds it open until the battery recovers to the reconnect voltage. This prevents the sustained low-voltage conditions that cause irreversible capacity loss in both lead-acid and lithium cells. The rotary switch on the unit allows the installer to select from several pre-set voltage profiles without any additional programming tools.\u003c\/p\u003e\n\n\u003cp\u003eThe remote input accepts a signal from an external source such as a Victron BMV battery monitor, a BMS, or a simple switch. This allows the BatteryProtect to be overridden or controlled as part of a wider system. The alarm output can drive an LED indicator or feed a signal to a monitoring system, giving advance notice before the full disconnect occurs. These features make it straightforward to integrate into both simple and more complex off-grid or marine DC systems.\u003c\/p\u003e\n\n\u003cp\u003eAt 100A, this unit covers a wide range of 48V load scenarios including inverter pre-loads, DC distribution boards, and auxiliary circuits. It is not a charge controller and should be wired on the load side of the battery, not between the battery and charger.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBPR048100400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSystem Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Current Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076021469\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems with 48V battery banks requiring automatic load disconnect on low voltage.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat DC systems where battery protection is required on auxiliary load circuits.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle conversions running 48V DC distribution.\u003c\/li\u003e\n  \u003cli\u003eTelecom and remote monitoring installations with 48V battery backup.\u003c\/li\u003e\n  \u003cli\u003eAny 48V DC system where preventing battery over-discharge is a design requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron BatteryProtect 48V-100A (BPR048100400)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect must be installed on the load side of the battery, between the battery bank and the DC loads. It must not be placed in the charge circuit. Wiring should be sized appropriately for 100A continuous current and protected with a suitably rated fuse. Installation in 48V systems should be carried out by a qualified electrician or experienced system integrator familiar with DC battery systems. For systems connected to solar PV or grid-tied equipment, ensure all relevant wiring regulations and local compliance requirements are observed.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551510307,"sku":"BPR048100400","price":126.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-batteryprotect-48v-100a-bpr048100400-488352.jpg?v=1789116135"},{"product_id":"victron-multiplus-ii-48-8000-110-100-230v","title":"Victron MultiPlus-II 48\/8000\/110-100 230V - PMP482805000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 48\/8000\/110-100 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 48\/8000\/110-100 is a combined inverter and battery charger rated at 8000VA continuous output, designed for demanding off-grid, backup and hybrid solar installations. It accepts a 48V battery bank and delivers 230V AC output, with a 110A battery charger and 100A AC transfer switch built in. Suitable for residential, commercial and industrial applications where high power capacity and reliable grid or generator interaction are required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8000VA continuous inverter output with a 16000W peak surge capacity, suitable for high-load equipment and motor starting.\u003c\/li\u003e\n  \u003cli\u003e110A multi-stage battery charger with adaptive charge algorithm, compatible with lead-acid (AGM, gel, flooded) and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003e100A AC transfer switch enables fast changeover between grid, generator and inverter power with minimal interruption.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions allow the unit to limit AC input draw and supplement it with battery power, preventing generator or grid overload.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in battery monitor tracks state of charge, allowing accurate management without a separate device.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase operation: up to six units can be configured in parallel for increased capacity or in three-phase arrangements.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for integration with GX devices, enabling full system monitoring and control via VRM or Cerbo GX.\u003c\/li\u003e\n  \u003cli\u003eProgrammable relay and configurable charge\/discharge parameters via VEConfigure software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/8000\/110-100 is built around a pure sine wave inverter stage that operates from a 48V DC battery bank. At 8000VA, it can handle large residential loads, commercial equipment or multiple circuits simultaneously. The 110A charger is not a simple bulk charger: it uses Victron's adaptive four-stage algorithm (bulk, absorption, float, storage) and can be configured for different battery chemistries and capacities through VEConfigure software.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is a particularly useful feature in generator or limited-grid scenarios. When AC input is available but limited (for example, a small generator or a restricted grid connection), the MultiPlus-II can draw the maximum permitted current from the source and supplement the remainder from the battery bank. This avoids tripping breakers or overloading a generator while still meeting peak load demand. PowerControl performs the complementary function of capping AC input draw to a user-defined limit.\u003c\/p\u003e\n\n\u003cp\u003eThe unit supports parallel and three-phase configurations without additional hardware beyond the units themselves and VE.Bus cabling. Up to six MultiPlus-II units can be paralleled for a maximum of 48kVA in single-phase, or arranged as a balanced three-phase system. This scalability makes it practical for larger off-grid sites, commercial backup systems and microgrid installations where load growth is anticipated.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482805000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8000VA \/ 8000W continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCharger Output Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e110A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Transfer Switch Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePeak Surge Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e16000W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eParallel \/ Three-Phase\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (up to 6 units)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e40.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076050568\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and commercial solar installations requiring high continuous power output.\u003c\/li\u003e\n  \u003cli\u003eHybrid solar systems with grid or generator backup, where PowerAssist is used to manage limited AC input capacity.\u003c\/li\u003e\n  \u003cli\u003eThree-phase commercial or industrial backup systems using multiple MultiPlus-II units in a configured array.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle installations where a 48V battery bank and high AC output are required.\u003c\/li\u003e\n  \u003cli\u003eMicrogrid and community energy projects requiring scalable, paralleled inverter capacity.\u003c\/li\u003e\n  \u003cli\u003eCritical load backup for server rooms, medical facilities or communications infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MultiPlus-II 48\/8000\/110-100 230V inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 48\/8000\/110-100 operates at high DC currents from a 48V battery bank and must be installed by a qualified electrician or accredited installer. In the UK, grid-connected or grid-interactive installations must comply with G98 or G99 requirements depending on export capacity and connection type. Configuration via VEConfigure software should be carried out by a competent person familiar with Victron systems. Lithium battery installations require correct charge profile settings and, where applicable, BMS communication to be configured before commissioning. The unit's weight of 40.8 kg means appropriate lifting and mounting provisions are required during installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551543075,"sku":"PMP482805000","price":1264.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-multiplus-ii-488000110-100-230v-pmp482805000-770454.jpg?v=1789114973"},{"product_id":"victron-batteryprotect-12-24v-65a","title":"Victron BatteryProtect 12\/24V-65A - BPR000065400","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron BatteryProtect 12\/24V 65A\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BatteryProtect 12\/24V-65A is an electronic battery protection device that disconnects a load from the battery when voltage drops to a damaging level. It is designed for 12V and 24V systems and suits marine, off-grid, and vehicle installations where over-discharge protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 65A continuous current, suitable for moderate to heavy DC loads.\u003c\/li\u003e\n  \u003cli\u003eCompatible with both 12V and 24V battery systems without manual adjustment.\u003c\/li\u003e\n  \u003cli\u003eProgrammable low-voltage disconnect and reconnect thresholds via a rotary switch.\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input allows integration with a BMS or external control signal.\u003c\/li\u003e\n  \u003cli\u003eVery low self-consumption, drawing less than 1mA in standby.\u003c\/li\u003e\n  \u003cli\u003eSolid-state switching with no mechanical relay contacts to wear out.\u003c\/li\u003e\n  \u003cli\u003eAlarm output available to signal low-voltage conditions to external devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect monitors battery voltage continuously and disconnects the load circuit when voltage falls below the programmed threshold. This prevents deep discharge, which is the primary cause of premature battery failure in lead-acid and lithium systems. Once the battery recovers to the reconnect voltage, the unit automatically restores the load connection after a short delay.\u003c\/p\u003e\n\n\u003cp\u003eThe rotary switch provides several pre-set voltage profiles covering common battery chemistries and system voltages. The remote input accepts a signal from a battery management system, allowing the BMS to trigger a disconnect independently of the voltage threshold. This makes the BatteryProtect a practical last-line-of-defence in lithium battery installations where the BMS needs to shed loads quickly.\u003c\/p\u003e\n\n\u003cp\u003eSolid-state switching means there are no relay contacts to corrode or wear, which is particularly relevant in marine and humid environments. The alarm output can drive an LED or feed a signal to a monitoring system, giving the user advance warning before a full disconnect occurs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPR000065400\u003c\/li\u003e\n  \u003cli\u003eSystem voltage: 12V or 24V (auto-detect)\u003c\/li\u003e\n  \u003cli\u003eContinuous current rating: 65A\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.205 kg\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076034193\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOver-discharge protection for lead-acid and lithium batteries in off-grid solar systems.\u003c\/li\u003e\n  \u003cli\u003eLoad disconnect in marine and narrowboat 12V or 24V house battery banks.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome auxiliary battery protection.\u003c\/li\u003e\n  \u003cli\u003eBMS-controlled load shedding in lithium battery installations.\u003c\/li\u003e\n  \u003cli\u003eCaravan and campervan DC load protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron BatteryProtect 12\/24V-65A unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect must be installed in the load circuit only, never between the battery and a charger. It is not suitable for use with inverters or other inductive loads unless specified. Wiring should be sized appropriately for the 65A rating and protected with a fuse at the battery. Installation by a qualified 12V or marine electrician is recommended, particularly in lithium battery systems where correct BMS integration is essential.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551575843,"sku":"BPR000065400","price":33.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-batteryprotect-1224v-65a-bpr000065400-621262.jpg?v=1789116118"},{"product_id":"victron-battery-alarm-gx-retail","title":"Victron Battery Alarm GX Retail - BPA000100010R","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBattery Alarm GX Retail — BPA000100010R\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Battery Alarm GX is a compact audible and visual alarm unit designed to work with Victron GX devices. It provides a local alert when battery voltage drops to a critical level, giving installers and end users an immediate, on-site warning without relying solely on remote monitoring software.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAudible and visual alarm triggered by low battery voltage conditions via a connected GX device.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for use with Victron GX product range, including the Cerbo GX and Color Control GX.\u003c\/li\u003e\n  \u003cli\u003eCompact, lightweight form factor at 0.2 kg, suitable for panel mounting or enclosure installation.\u003c\/li\u003e\n  \u003cli\u003eRetail packaging included, making it suitable for resale or end-user supply.\u003c\/li\u003e\n  \u003cli\u003eProvides a local, on-site alert independent of internet connectivity or VRM portal access.\u003c\/li\u003e\n  \u003cli\u003eSimple wired connection to the GX device relay output for straightforward integration into existing Victron systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Battery Alarm GX connects to the programmable relay output on a compatible Victron GX device. When the GX device triggers the relay (for example, on a low battery state of charge or low voltage condition), the alarm unit activates both an audible buzzer and a visual indicator. This gives anyone present at the installation an immediate alert, which is particularly useful in off-grid cabins, marine installations, or remote plant rooms where a user may not be monitoring the VRM portal.\u003c\/p\u003e\n\n\u003cp\u003eThe alarm is not a standalone unit. It requires a Victron GX device with a relay output to function. The relay trigger conditions are configured within the GX device settings, giving the installer full control over the threshold at which the alarm activates. This makes it adaptable to different battery chemistries and system configurations without any modification to the alarm unit itself.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPA000100010R\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021056\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.2 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Victron GX devices with relay output (e.g. Cerbo GX, Color Control GX)\u003c\/li\u003e\n  \u003cli\u003ePackaging: Retail\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems where a local low-battery warning is required at the installation site.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat installations to alert crew of critical battery conditions.\u003c\/li\u003e\n  \u003cli\u003eRemote cabins, lodges or plant rooms with Victron GX monitoring already installed.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and vehicle conversions using Victron GX-based battery management.\u003c\/li\u003e\n  \u003cli\u003eCommercial and residential battery storage systems where an audible alert is required as a backup to remote monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Battery Alarm GX unit (retail packaging)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe Battery Alarm GX must be connected to the relay output of a compatible Victron GX device. Relay trigger conditions should be configured by a qualified installer familiar with Victron GX system settings. Ensure the relay output voltage and current ratings of the GX device are compatible before wiring. Installation within a battery system should be carried out by a competent electrician or qualified solar installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551608611,"sku":"BPA000100010R","price":54.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-battery-alarm-gx-bpa000100010r-197469.jpg?v=1789116237"},{"product_id":"victron-batteryprotect-12-24v-100a","title":"Victron BatteryProtect 12\/24V-100A - BPR000100400","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron BatteryProtect 12\/24V-100A — BPR000100400\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BatteryProtect 12\/24V-100A is an automatic battery disconnect device designed to protect 12V and 24V lead-acid and lithium batteries from over-discharge. It is aimed at solar installers, off-grid system builders, marine electricians and vehicle conversion specialists who need a reliable, low-loss method of disconnecting DC loads before battery voltage drops to a damaging level.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 100A continuous DC current, suitable for substantial load banks in 12V and 24V systems.\u003c\/li\u003e\n  \u003cli\u003eAutomatic disconnect triggered by a user-selectable low-voltage threshold, protecting the battery from deep discharge damage.\u003c\/li\u003e\n  \u003cli\u003eAutomatic reconnect once battery voltage recovers to the preset level, removing the need for manual intervention.\u003c\/li\u003e\n  \u003cli\u003eCompatible with both 12V and 24V battery systems, making it versatile across a wide range of installations.\u003c\/li\u003e\n  \u003cli\u003eVery low voltage drop across the device, minimising resistive losses in the load circuit.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.5 kg, straightforward to mount in tight enclosures or battery compartments.\u003c\/li\u003e\n  \u003cli\u003eCan be used with an external remote on\/off signal, allowing integration with battery management systems or manual override switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect sits between the battery and the DC loads. When battery voltage falls below the programmed disconnect threshold, the device opens the load circuit, preventing further discharge. This matters in practice because discharging a lead-acid battery below approximately 50% state of charge repeatedly will shorten its service life significantly. For lithium batteries, over-discharge can cause irreversible cell damage or trigger the battery management system to lock out the pack entirely.\u003c\/p\u003e\n\n\u003cp\u003eThe 100A rating covers a wide range of DC loads including inverters, lighting circuits, pumps and refrigeration in caravans, motorhomes, boats and off-grid cabins. The automatic reconnect function means the system resumes normal operation once the battery has been recharged to the recovery threshold, without requiring the user to reset anything manually. The remote on\/off input adds flexibility for installations where the BatteryProtect needs to be controlled by an external BMS, a charge controller or a simple toggle switch.\u003c\/p\u003e\n\n\u003cp\u003eVictron offers the BatteryProtect in several current ratings. The 100A variant is the mid-range option, suited to systems where total DC load current does not exceed 100A. For higher-current applications, larger variants are available in the Victron range.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBPR000100400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVoltage Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V \/ 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Current Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076021438\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtecting leisure batteries in caravans, motorhomes and campervans from over-discharge by DC appliances.\u003c\/li\u003e\n  \u003cli\u003eMarine DC load protection on narrowboats, sailing yachts and motorboats with 12V or 24V house battery banks.\u003c\/li\u003e\n  \u003cli\u003eOff-grid solar systems where loads must be disconnected automatically during periods of low solar input or high consumption.\u003c\/li\u003e\n  \u003cli\u003eVehicle conversions and mobile workshops where battery protection is required for tools, lighting and ancillary equipment.\u003c\/li\u003e\n  \u003cli\u003eRemote telecoms and monitoring installations running from battery-backed DC supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron BatteryProtect 12\/24V-100A unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect should be installed by a competent electrician familiar with DC battery systems. It is a load-side disconnect device only and must not be placed in the charging circuit. Ensure all wiring is correctly rated for 100A continuous current and that appropriate fusing is fitted on the battery side of the installation in accordance with wiring regulations. For installations forming part of a larger solar PV or off-grid system, a qualified installer should commission the full system to ensure correct threshold settings and compatibility with the battery chemistry in use.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551641379,"sku":"BPR000100400","price":48.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-batteryprotect-1224v-100a-bpr000100400-790401.jpg?v=1789116124"},{"product_id":"victron-battery-balancer-24v-48v","title":"Victron Battery Balancer - BBA000100100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Battery Balancer\u003c\/h1\u003e\n\u003cp\u003eThe Victron Battery Balancer equalises the charge across two 12V batteries connected in series to form a 24V bank. It is designed for installers building 24V systems from 12V batteries, where small differences in cell condition or charge acceptance cause imbalance over time. Left uncorrected, this imbalance shortens battery life and reduces usable capacity. The Battery Balancer corrects this automatically without any need for programming or user adjustment.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBalances two 12V batteries wired in series in a 24V battery bank, correcting voltage differences between them.\u003c\/li\u003e\n\u003cli\u003eActivates automatically once the difference between the two batteries exceeds 0.1V, drawing up to 0.7A from the higher battery.\u003c\/li\u003e\n\u003cli\u003eRequires no configuration, software or user intervention once wired in.\u003c\/li\u003e\n\u003cli\u003eLED indicator shows balancing activity at a glance, making it easy to confirm correct operation during installation checks.\u003c\/li\u003e\n\u003cli\u003eMultiple Battery Balancers can be connected in series for 48V systems built from 12V batteries.\u003c\/li\u003e\n\u003cli\u003eCompact, sealed enclosure suited to installation in battery boxes, plant rooms and marine or vehicle compartments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIn a 24V bank made from two series-connected 12V batteries, one battery will often charge or discharge slightly faster than the other due to manufacturing tolerance, age or temperature variation. Over repeated cycles this drift widens, leading to one battery being consistently overcharged while the other is undercharged. The Battery Balancer monitors the midpoint voltage between the two batteries and draws current from the higher one whenever the imbalance exceeds 0.1V, bringing both batteries back into alignment.\u003c\/p\u003e\n\u003cp\u003eBecause the unit works passively and continuously, it requires no interaction with the charge controller, inverter or battery monitor. It sits alongside the battery bank and does its job independently, which makes it straightforward to retrofit into existing 24V systems as well as specify for new installations. For 48V banks built from four 12V batteries, two Battery Balancers are wired in series to cover both halves of the bank.\u003c\/p\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSKU: BBA000100100\u003c\/li\u003e\n\u003cli\u003eGTIN: 8719076020950\u003c\/li\u003e\n\u003cli\u003eWeight: 0.34 kg\u003c\/li\u003e\n\u003cli\u003eActivation threshold: 0.1V difference between batteries\u003c\/li\u003e\n\u003cli\u003eBalancing current: up to 0.7A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24V battery banks assembled from two 12V lead-acid, gel or AGM batteries in series.\u003c\/li\u003e\n\u003cli\u003e48V battery banks assembled from four 12V batteries, using two Battery Balancers.\u003c\/li\u003e\n\u003cli\u003eOff-grid solar installations where consistent charge balance extends battery service life.\u003c\/li\u003e\n\u003cli\u003eMarine and vehicle 24V systems where space for balancing equipment is limited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Victron Battery Balancer\u003c\/li\u003e\n\u003cli\u003eConnection cables for wiring across the battery pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eFit the Battery Balancer across the midpoint of the 24V bank, connecting to the positive and negative terminals of each battery in the series pair. Confirm battery chemistry and wiring configuration before installation. For 48V banks, install two units in series and verify polarity carefully. As with any DC battery wiring work, use a qualified installer where the system forms part of a wider solar PV, inverter or off-grid installation.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551674147,"sku":"BBA000100100","price":45.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-battery-balancer-bba000100100-212552.jpg?v=1789116101"},{"product_id":"victron-autotransformer-120-240v-32a","title":"Victron Autotransformer 120\/240V-32A - ITR000100001","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy Autotransformer 120\/240V 32A — ITR000100001\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Autotransformer 120\/240V-32A is a split-phase voltage conversion unit designed for installations where 120V and 240V AC distribution is required from a single-phase source. It is suited to off-grid systems, marine applications, and North American-standard electrical setups where split-phase power is needed. At 32A continuous rating, it handles substantial loads without the bulk and cost of a full isolation transformer.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConverts between 120V and 240V split-phase AC, enabling North American-standard distribution from a single-phase input.\u003c\/li\u003e\n  \u003cli\u003e32A continuous current rating supports high-demand loads across both legs of a split-phase system.\u003c\/li\u003e\n  \u003cli\u003eAutotransformer design is more compact and efficient than a full isolation transformer for voltage-splitting applications.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron inverter\/charger systems, allowing split-phase output from a single MultiPlus or Quattro unit.\u003c\/li\u003e\n  \u003cli\u003eRobust toroidal core construction keeps no-load losses low and reduces audible hum during operation.\u003c\/li\u003e\n  \u003cli\u003eWeight of 12.8 kg reflects a substantial copper-wound core, appropriate for the rated current capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eAn autotransformer differs from an isolation transformer in that the primary and secondary windings share a common electrical connection rather than being magnetically isolated. This makes it well suited to voltage-splitting duties, where the goal is to derive a 120V\/120V split-phase output from a 240V single-phase source, or to combine two 120V legs into a 240V supply. The shared winding means lower copper losses and a more compact unit for a given power rating compared to a fully isolated design.\u003c\/p\u003e\n\n\u003cp\u003eIn practice, this unit is commonly used alongside Victron MultiPlus or Quattro inverter\/chargers in North American off-grid or marine installations. A single inverter producing 240V AC can feed the autotransformer to create the balanced 120V\/120V split-phase supply that North American appliances and distribution panels expect. The 32A rating at 240V equates to a maximum throughput of approximately 7.68kVA, which covers most residential and light commercial off-grid loads.\u003c\/p\u003e\n\n\u003cp\u003eBecause this is an autotransformer and not an isolation transformer, it does not provide galvanic isolation between input and output. Where isolation is a safety or regulatory requirement, a separate isolation transformer must be used. Installers should confirm the requirements of the installation before specifying this unit.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eITR000100001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVoltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e120\/240V AC split-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous current rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum throughput\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eApprox. 7.68 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransformer type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAutotransformer (no galvanic isolation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076022404\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid systems using North American-standard 120V\/240V split-phase distribution panels.\u003c\/li\u003e\n  \u003cli\u003eMarine and yacht installations requiring split-phase AC from a single inverter output.\u003c\/li\u003e\n  \u003cli\u003eRV and motorhome builds where North American appliances require a balanced split-phase supply.\u003c\/li\u003e\n  \u003cli\u003ePairing with a Victron MultiPlus or Quattro to create a split-phase output from a single 240V inverter unit.\u003c\/li\u003e\n  \u003cli\u003eLight commercial off-grid installations with mixed 120V and 240V load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy Autotransformer 120\/240V-32A (ITR000100001)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis autotransformer must be installed by a qualified electrician familiar with split-phase AC systems. It does not provide galvanic isolation, so it is not a substitute for an isolation transformer where isolation is required by regulation or for safety. Ensure all wiring is rated for the full 32A load and that appropriate overcurrent protection is fitted on both the input and output sides. Confirm compatibility with your inverter or AC source before installation. For marine installations, check compliance with applicable shore power and electrical safety standards.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551772451,"sku":"ITR000100001","price":465.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-autotransformer-120240v-32a-itr000100001-226084.jpg?v=1789115887"},{"product_id":"victron-batteryprotect-12-24v-220a","title":"Victron BatteryProtect 12\/24V-220A - BPR000220400","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron BatteryProtect 12\/24V-220A — BPR000220400\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron BatteryProtect 12\/24V-220A is an automatic battery disconnect device designed to protect 12V and 24V lead-acid and lithium batteries from over-discharge. It disconnects the load before the battery reaches a damaging low-voltage threshold, preserving battery life and preventing system failure. Suited to marine, off-grid, vehicle and industrial applications where reliable battery protection is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRated at 220A continuous current, suitable for high-load 12V and 24V systems.\u003c\/li\u003e\n  \u003cli\u003eAutomatic disconnect and reconnect based on configurable voltage thresholds, protecting batteries from deep discharge damage.\u003c\/li\u003e\n  \u003cli\u003eCompatible with both 12V and 24V battery systems, covering a wide range of installations.\u003c\/li\u003e\n  \u003cli\u003eVery low self-consumption, minimising parasitic drain on the battery when the system is idle.\u003c\/li\u003e\n  \u003cli\u003eAlarm output available to signal low-voltage conditions before disconnection occurs.\u003c\/li\u003e\n  \u003cli\u003eRemote on\/off input allows integration with external control systems or battery management systems (BMS).\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.912 kg, making it practical to install in confined spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect monitors battery voltage continuously and disconnects the load circuit when voltage drops to a preset threshold. This prevents the battery from being discharged beyond its safe operating limit, which is a common cause of premature battery failure in off-grid, marine and vehicle installations. Once the battery voltage recovers to the reconnect threshold, the BatteryProtect automatically restores the load connection.\u003c\/p\u003e\n\n\u003cp\u003eAt 220A, this unit handles substantial load currents, making it appropriate for systems running inverters, pumps, winches or other high-draw equipment. The remote on\/off input adds flexibility for installations where the BatteryProtect needs to be controlled by a BMS or an external switch. The alarm output can be wired to a warning indicator, giving advance notice of a low-voltage condition before the load is shed.\u003c\/p\u003e\n\n\u003cp\u003eThe device is designed for use on the load side of the battery, not between the battery and a charger. It should not be used to disconnect charging sources. This distinction is important during system design to ensure correct protection behaviour.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBPR000220400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVoltage Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V \/ 24V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Current Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e220A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.912 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076021452\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar systems where battery over-discharge protection is required on the load circuit.\u003c\/li\u003e\n  \u003cli\u003eMarine installations protecting house battery banks from excessive discharge.\u003c\/li\u003e\n  \u003cli\u003eMotorhomes, campervans and commercial vehicles with auxiliary battery systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and telecoms backup power systems requiring automatic load shedding at low voltage.\u003c\/li\u003e\n  \u003cli\u003eAny 12V or 24V system running high-current loads such as inverters, pumps or winches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron BatteryProtect 12\/24V-220A (BPR000220400)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe BatteryProtect must be installed on the load side of the battery only. Do not use it to interrupt charging current, as this can damage the unit. Installation should be carried out by a qualified electrician or experienced system integrator familiar with DC battery systems. Ensure all connections are correctly rated for 220A and that appropriate fusing is in place between the battery and the device. For off-grid solar installations, a qualified installer should verify that the protection settings are compatible with the battery chemistry in use.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632551837987,"sku":"BPR000220400","price":83.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-batteryprotect-1224v-220a-bpr000220400-198847.jpg?v=1789116130"},{"product_id":"victron-battery-switch-on-off-275a","title":"Victron Battery switch ON\/OFF 275A - VBS127010010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eBattery Switch ON\/OFF 275A — VBS127010010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Battery Switch ON\/OFF 275A is a heavy-duty manual isolation switch designed for disconnecting battery banks in marine, vehicle and off-grid installations. Rated at 275A continuous, it provides a reliable means of isolating the battery from the load circuit for maintenance, storage or emergency shutdown.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e275A continuous current rating suitable for high-load 12V and 24V battery systems.\u003c\/li\u003e\n  \u003cli\u003eSimple ON\/OFF operation for fast, positive battery isolation without tools.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 232g, suitable for panel mounting in confined spaces.\u003c\/li\u003e\n  \u003cli\u003eRobust contact design rated to handle the high inrush currents typical of inverter and motor loads.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard busbar and battery main switch installations in marine, motorhome and off-grid applications.\u003c\/li\u003e\n  \u003cli\u003eSKU VBS127010010 with GTIN 8719076052258 for straightforward procurement and stock management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eA battery isolation switch is a fundamental safety component in any DC system. It allows the battery bank to be completely disconnected from the rest of the electrical circuit, which is essential during maintenance, when the vehicle or vessel is laid up, or in the event of a fault. The 275A rating means this switch can handle the sustained current demands of inverters, bow thrusters, winches and other high-draw equipment without thermal degradation of the contacts.\u003c\/p\u003e\n\n\u003cp\u003eThe ON\/OFF design keeps operation straightforward. There is no rotary selector or multiple positions to misread: the switch is either open or closed. This matters in emergency situations where a crew member or technician needs to isolate the system quickly. The compact form factor makes it practical to mount in battery compartments, distribution panels or engine bays where space is limited.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVBS127010010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eContinuous Current Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e275A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSwitch Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eON\/OFF (manual isolation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e232g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076052258\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBattery isolation on narrowboats, sailing yachts and motorboats.\u003c\/li\u003e\n  \u003cli\u003eMain battery disconnect on motorhomes, campervans and HGV auxiliary systems.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabin and caravan battery banks requiring manual isolation.\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial DC systems where a lockout-capable main switch is required.\u003c\/li\u003e\n  \u003cli\u003eReplacement or upgrade of existing battery main switches in Victron-based systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy Battery Switch ON\/OFF 275A (VBS127010010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis switch should be installed by a competent electrician or qualified marine\/vehicle electrical engineer. Ensure all connections are correctly torqued and that cable sizing is appropriate for the 275A rating before commissioning. Isolate all loads before fitting or removing the switch. For installations forming part of a grid-connected or MCS-accredited solar system, work should be carried out by a qualified installer.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632552263971,"sku":"VBS127010010","price":30.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-battery-switch-onoff-275a-vbs127010010-794475.jpg?v=1789114657"},{"product_id":"victron-energy-meter-et340-3-phase-65a","title":"Victron Energy Meter ET340 - 3 phase - max 65A\/phase - REL300300000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eEnergy Meter ET340 — 3 Phase — Max 65A\/Phase — REL300300000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Meter ET340 is a three-phase energy meter designed to monitor AC energy flows in solar, grid and generator systems. It connects to Victron GX devices and provides real-time consumption, production and import\/export data across all three phases. Suitable for professional installers integrating Victron systems into three-phase residential, commercial or industrial installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase energy monitoring with a maximum measurement current of 65A per phase.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices (Cerbo GX, Color Control GX, Venus GX) via RS-485 Modbus communication.\u003c\/li\u003e\n  \u003cli\u003eMeasures both import and export energy, making it suitable for grid-tied solar installations with feed-in monitoring.\u003c\/li\u003e\n  \u003cli\u003eCan be used as a grid meter, PV inverter meter or load meter within the Victron ecosystem.\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting for straightforward installation inside a distribution board or enclosure.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.23 kg, with a compact form factor suited to standard electrical enclosures.\u003c\/li\u003e\n  \u003cli\u003eSupports multiple meter roles simultaneously when used alongside other Victron monitoring hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ET340 connects to a Victron GX device over RS-485 using the Victron USB to RS-485 interface cable (sold separately). Once connected, the GX device reads energy data from the meter and displays it in the VRM portal and on local GX displays. This allows installers and system owners to track grid consumption, solar yield and load behaviour in real time and historically.\u003c\/p\u003e\n\n\u003cp\u003eThe 65A per phase rating covers the majority of three-phase residential and light commercial installations without the need for external current transformers, simplifying wiring and reducing installation time. For higher-current applications, external CTs are required and the meter must be sized accordingly. The ET340 is specifically designed for use within the Victron ecosystem and is not a standalone energy monitor.\u003c\/p\u003e\n\n\u003cp\u003eWhen deployed as a grid meter, the ET340 enables ESS (Energy Storage System) functionality on compatible Victron systems, allowing the system to respond to grid import and export in real time. This is a key requirement for any Victron ESS installation on a three-phase supply.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eREL300300000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhases\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum current per phase\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e65A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRS-485 Modbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.23 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076039693\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid metering in three-phase Victron ESS installations to enable import\/export control.\u003c\/li\u003e\n  \u003cli\u003eMonitoring AC output of third-party three-phase PV inverters connected to a Victron system.\u003c\/li\u003e\n  \u003cli\u003eLoad monitoring on three-phase distribution boards in commercial or industrial premises.\u003c\/li\u003e\n  \u003cli\u003eThree-phase solar installations in light commercial buildings where per-phase consumption data is required.\u003c\/li\u003e\n  \u003cli\u003eRetrofit monitoring in existing three-phase installations being upgraded with Victron GX equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy Meter ET340 (3-phase, 65A\/phase)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ET340 must be installed by a qualified electrician. It is a direct-connect meter rated to 65A per phase; installations exceeding this current require appropriately rated current transformers. Connection to a Victron GX device requires a USB to RS-485 interface cable, which is not included. Ensure the GX device firmware is up to date to guarantee full ET340 compatibility. For grid-connected ESS systems in the UK, the overall installation must comply with G98 or G99 requirements as applicable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555180323,"sku":"REL300300000","price":74.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-energy-meter-et340-3-phase-max-65aphase-rel300300000-591173.jpg?v=1789115707"},{"product_id":"victron-easysolar-ii-48-3000-35-32-mppt-250-70-gx","title":"Victron EasySolar-II 48\/3000\/35-32 MPPT 250\/70 GX - PMP482307010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eEasySolar-II 48\/3000\/35-32 MPPT 250\/70 GX — PMP482307010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron EasySolar-II 48\/3000\/35-32 MPPT 250\/70 GX is an all-in-one inverter charger combining a 3000VA inverter, 35A MPPT solar charger, and 32A AC battery charger in a single wall-mounted unit. It includes the GX device for system monitoring and control, making it suited to off-grid installations, home storage systems, and self-consumption applications where space and wiring complexity need to be minimised.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA \/ 2400W pure sine wave inverter output at 230V AC, operating from a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 70A MPPT solar charge controller rated for up to 250V open-circuit PV input voltage.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in 32A AC battery charger with adaptive charging algorithm for lead-acid and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eIntegrated GX device provides full system monitoring, VRM portal connectivity, and DVCC support without requiring a separate Cerbo GX or Color Control unit.\u003c\/li\u003e\n  \u003cli\u003ePowerAssist function allows the unit to supplement shore or generator power, preventing overload on limited AC sources.\u003c\/li\u003e\n  \u003cli\u003eSingle enclosure design reduces installation time and wiring compared to separate component systems.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus, VE.Direct, and VE.Can accessories for expanded system integration.\u003c\/li\u003e\n  \u003cli\u003eConfigurable via VictronConnect app over Bluetooth or via the GX interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EasySolar-II integrates the core components of a solar power system into one enclosure. The 250\/70 MPPT charge controller can handle PV arrays with an open-circuit voltage up to 250V and a maximum charge current of 70A into a 48V battery bank. This is sufficient for a mid-sized off-grid or self-consumption system without requiring a separate charge controller and the associated DC wiring between units.\u003c\/p\u003e\n\n\u003cp\u003eThe GX device built into this variant replaces the need for a standalone Cerbo GX or CCGX. It provides access to the VRM online portal for remote monitoring, supports DVCC (Distributed Voltage and Current Control) for managed battery systems including many lithium BMS types, and allows integration with generators, grid meters, and tank sensors. This makes the unit particularly practical for installations where a full Victron system is required but panel space or budget for additional hardware is limited.\u003c\/p\u003e\n\n\u003cp\u003eThe 32A charger and PowerAssist function allow the unit to work alongside a generator or limited grid connection. When AC input is available, the charger tops up the battery bank. When load demand exceeds the AC input capacity, PowerAssist draws additional power from the battery to prevent tripping the source. This is a common requirement in off-grid cabins, boats, and backup power setups.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482307010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Charger Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMPPT Charge Controller\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250\/70 (250V max PV VOC, 70A max charge current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGX Device\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated (VRM, DVCC, VE.Bus, VE.Direct, VE.Can)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e28 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076045786\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential and rural properties requiring a complete solar power system in a compact installation.\u003c\/li\u003e\n  \u003cli\u003eHome storage and self-consumption systems where grid backup is available but solar self-use is prioritised.\u003c\/li\u003e\n  \u003cli\u003eNarrowboats, canal boats, and larger leisure vessels with 48V battery banks.\u003c\/li\u003e\n  \u003cli\u003eRemote cabins, lodges, and agricultural buildings without grid connection.\u003c\/li\u003e\n  \u003cli\u003eGenerator-backed off-grid systems where PowerAssist reduces generator run time.\u003c\/li\u003e\n  \u003cli\u003eBackup power installations for critical loads requiring automatic transfer and battery support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEasySolar-II 48\/3000\/35-32 MPPT 250\/70 GX unit (wall-mount enclosure)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit operates at 48V DC with high DC currents and connects to 230V AC mains. Installation must be carried out by a qualified electrician familiar with battery-based inverter systems. For any grid-connected application, compliance with G98 or G99 (as applicable) and notification to the local Distribution Network Operator (DNO) is required. Lithium battery integration via DVCC requires a compatible BMS with VE.Can or VE.Direct communication. At 28 kg, the enclosure requires two people or mechanical assistance for wall mounting. Ensure the mounting surface and fixings are rated for the unit's weight.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555311395,"sku":"PMP482307010","price":1059.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-easysolar-ii-48300035-32-mppt-25070-gx-pmp482307010-809906.jpg?v=1789114952"},{"product_id":"victron-lifepo4-12v-100ah-smart-battery","title":"Victron LiFePO4 Battery 12,8V\/100Ah Smart - BAT512110610","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron LiFePO4 Battery 12.8V 100Ah Smart\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron LiFePO4 12.8V 100Ah Smart is a lithium iron phosphate battery with integrated Bluetooth, designed for solar storage, off-grid systems, marine and vehicle applications. It is built for professional installations where cycle life, charge efficiency and remote monitoring matter.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLithium iron phosphate (LiFePO4) chemistry provides a stable, safe cell with a long cycle life compared to lead-acid alternatives.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Bluetooth allows direct communication with the VictronConnect app for real-time state of charge, voltage, current and temperature monitoring.\u003c\/li\u003e\n  \u003cli\u003eNominal voltage of 12.8V and 100Ah capacity, giving 1.28kWh of usable energy in a single unit.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Battery Management System (BMS) protects against over-charge, over-discharge, over-temperature and short circuit conditions.\u003c\/li\u003e\n  \u003cli\u003eWeighs 14.01kg, significantly lighter than an equivalent lead-acid battery of the same capacity.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron charge controllers, inverter\/chargers and the wider Victron ecosystem via VE.Bus and VE.Direct where applicable.\u003c\/li\u003e\n  \u003cli\u003eMultiple units can be connected in series or parallel to increase voltage or capacity for larger system builds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eLiFePO4 chemistry is the preferred choice for professional solar and off-grid installations. Unlike standard lithium-ion cells, LiFePO4 does not use cobalt, which makes it thermally stable and far less prone to thermal runaway. The Victron Smart variant adds an integrated Bluetooth module, removing the need for a separate battery monitor in many applications and giving installers and end users direct visibility of battery state via a smartphone.\u003c\/p\u003e\n\n\u003cp\u003eThe internal BMS is a critical component. It manages cell balancing and enforces protection thresholds, which means the battery will disconnect under fault conditions rather than allow damage to the cells or connected equipment. This is particularly important in unattended off-grid and marine installations. The BMS also communicates with compatible Victron charge sources, allowing coordinated charge management across the system.\u003c\/p\u003e\n\n\u003cp\u003eAt 100Ah and 12.8V nominal, this battery delivers 1.28kWh gross capacity. LiFePO4 cells can be discharged to a much deeper level than lead-acid without damage, so the usable capacity in practice is considerably higher than an equivalent-rated lead-acid unit. Cycle life is also substantially longer, making the total cost of ownership lower over the life of a system.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBAT512110610\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12.8V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCapacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100Ah\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eEnergy\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e1.28kWh\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eChemistry\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLithium Iron Phosphate (LiFePO4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (VictronConnect app)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBMS\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e14.01kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076043041\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar storage systems in residential, agricultural and remote site installations.\u003c\/li\u003e\n  \u003cli\u003eMarine house battery banks where weight saving and deep cycle performance are priorities.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and campervan leisure battery systems requiring reliable, monitored power.\u003c\/li\u003e\n  \u003cli\u003eBackup power for telecoms, security and critical equipment.\u003c\/li\u003e\n  \u003cli\u003eMobile and portable power systems where a lightweight, high-capacity battery is required.\u003c\/li\u003e\n  \u003cli\u003eExpanding existing Victron-based systems by adding capacity in parallel configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron LiFePO4 12.8V 100Ah Smart battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis battery should be installed by a qualified electrician or experienced system integrator familiar with lithium battery systems. Ensure the charge source (solar charge controller, inverter\/charger or DC-DC charger) is configured for LiFePO4 charge profiles before connecting. Do not mix battery chemistries within the same bank. When connecting multiple units in series to achieve 24V or 48V, verify that the BMS and charge sources are rated and configured for the resulting system voltage. For solar PV installations, a qualified MCS-accredited installer is recommended.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555409699,"sku":"BAT512110610","price":658.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-lifepo4-battery-128v100ah-smart-bat512110610-828297.jpg?v=1789115199"},{"product_id":"victron-lifepo4-25-6v-200ah-smart-battery","title":"Victron LiFePO4 Battery 25,6V\/200Ah Smart-a - BAT524120610","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron LiFePO4 Battery 25.6V 200Ah Smart — BAT524120610\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron LiFePO4 25.6V 200Ah Smart is a lithium iron phosphate battery with integrated Bluetooth, designed for off-grid, marine, and mobile power systems. It provides 5.12kWh of usable capacity in a single unit and communicates directly with compatible Victron charge controllers and inverter\/chargers via VE.Smart networking. Suited to professional installers building 24V battery banks where cycle life, depth of discharge, and remote monitoring matter.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e25.6V nominal lithium iron phosphate chemistry, offering a stable discharge curve and long cycle life compared to lead-acid alternatives.\u003c\/li\u003e\n  \u003cli\u003e200Ah capacity, delivering 5.12kWh per unit with the ability to discharge to a greater depth of discharge than VRLA or AGM batteries.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Bluetooth with the VictronConnect app, allowing real-time monitoring of state of charge, voltage, current, and temperature from a mobile device.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Battery Management System (BMS) providing cell balancing, over-voltage, under-voltage, over-current, and over-temperature protection.\u003c\/li\u003e\n  \u003cli\u003eVE.Smart networking compatibility, enabling the battery to share data with Victron MPPT charge controllers and MultiPlus\/Quattro inverter\/chargers for coordinated charging.\u003c\/li\u003e\n  \u003cli\u003eBatteries can be connected in parallel to increase capacity, or in series pairs to build a 51.2V bank, giving flexibility for larger system designs.\u003c\/li\u003e\n  \u003cli\u003eWeight of 37.5kg, consistent with the energy density typical of LiFePO4 at this capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\n\u003cp\u003eLiFePO4 chemistry is the preferred choice for professional off-grid and mobile installations where cycle life and safety are priorities. Unlike NMC lithium chemistries, LiFePO4 is thermally stable and does not present the same thermal runaway risk, which is a significant consideration in enclosed spaces such as boat bilges, vehicle battery compartments, or battery cabinets. Victron's 25.6V Smart series integrates the BMS directly into the battery casing, removing the need for a separate external BMS unit in single-battery or parallel configurations.\u003c\/p\u003e\n\n\u003cp\u003eThe built-in Bluetooth and VE.Smart networking mean this battery is not a passive component. It actively shares state-of-charge and temperature data with the rest of the Victron system, allowing MPPT charge controllers to apply temperature-compensated charging and enabling the MultiPlus or Quattro to adjust absorption and float parameters accordingly. This level of integration is only available within the Victron ecosystem and requires compatible firmware versions on connected devices.\u003c\/p\u003e\n\n\u003cp\u003eAt 200Ah and 25.6V, a single unit provides 5.12kWh. Two units in parallel give 10.24kWh at 24V. For 48V systems, two batteries can be connected in series to form a 51.2V 200Ah bank, though series configurations require careful attention to balancing and must follow Victron's published wiring guidelines. Always verify the maximum parallel and series configurations permitted by Victron before designing the bank.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBAT524120610\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e25.6V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCapacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e200Ah\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eEnergy\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5.12kWh\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eChemistry\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLithium Iron Phosphate (LiFePO4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (VictronConnect), VE.Smart networking\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBMS\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e37.5kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076054610\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar storage systems using Victron MultiPlus or Quattro inverter\/chargers at 24V.\u003c\/li\u003e\n  \u003cli\u003eMarine house battery banks where LiFePO4 thermal stability and weight reduction over lead-acid are required.\u003c\/li\u003e\n  \u003cli\u003eMotorhome and campervan leisure battery installations requiring deep-cycle performance and Bluetooth monitoring.\u003c\/li\u003e\n  \u003cli\u003eMobile and vehicle-based power systems where space and weight constraints favour lithium over AGM.\u003c\/li\u003e\n  \u003cli\u003eParallel battery banks for larger off-grid cabins, lodges, or remote telecoms installations.\u003c\/li\u003e\n  \u003cli\u003e48V system builds using two units in series, combined with compatible Victron 48V equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron LiFePO4 25.6V 200Ah Smart battery (BAT524120610)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis battery operates at 25.6V nominal and must be charged using a charger or inverter\/charger with a compatible LiFePO4 charge profile. Installation should be carried out by a qualified electrician or accredited installer familiar with lithium battery systems. The integrated BMS provides protection functions, but correct fusing, cabling, and system design remain the installer's responsibility. For parallel or series configurations, follow Victron's published guidelines on maximum bank size, inter-battery cabling, and BMS coordination. In marine or vehicle installations, ensure adequate ventilation and secure mechanical mounting to prevent movement. This product is not suitable for use with chargers configured for lead-acid chemistry.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555376931,"sku":"BAT524120610","price":1844.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-lifepo4-battery-256v200ah-smart-bat524120610-288498.jpg?v=1789115189"},{"product_id":"victron-easysolar-ii-48-5000-70-50-mppt-250-100-gx","title":"Victron EasySolar-II 48\/5000\/70-50 MPPT 250\/100 GX - PMP482507010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron EasySolar-II 48\/5000\/70-50 MPPT 250\/100 GX — PMP482507010\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron EasySolar-II 48\/5000\/70-50 MPPT 250\/100 GX is an all-in-one solar inverter charger combining a 5000VA inverter, 70A battery charger, 100A MPPT solar charge controller and the GX monitoring platform in a single wall-mounted unit. It is designed for 48V battery systems and suits residential self-consumption, home storage and off-grid installations where a compact, integrated solution is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5000VA \/ 4000W pure sine wave inverter output at 230V AC, suitable for demanding household and light commercial loads.\u003c\/li\u003e\n  \u003cli\u003eIntegrated 100A MPPT solar charge controller with a 250V maximum PV open-circuit voltage, supporting larger PV array configurations.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in 70A multi-stage battery charger compatible with 48V lead-acid and lithium battery banks.\u003c\/li\u003e\n  \u003cli\u003eGX device integrated as standard, providing full VRM portal connectivity, remote monitoring and system configuration without additional hardware.\u003c\/li\u003e\n  \u003cli\u003eSingle-enclosure design reduces installation complexity and wiring compared to separate component installations.\u003c\/li\u003e\n  \u003cli\u003eSupports PowerAssist functionality, allowing the unit to supplement a limited AC input (generator or shore power) with battery power to meet peak loads.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron's VE.Bus, VE.Direct and VE.Can communication protocols for integration with external BMS, displays and accessories.\u003c\/li\u003e\n  \u003cli\u003eWeight of 38.8 kg in a wall-mount enclosure, suitable for fixed indoor installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EasySolar-II range consolidates components that would otherwise require separate mounting, wiring and commissioning into one pre-integrated unit. The 48\/5000\/70-50 variant pairs a 5kVA inverter with a 100A MPPT controller rated to 250V input, which means it can accept a reasonably sized PV string without requiring a separate charge controller or additional DC cabling between components. This matters on installations where panel count is significant and DC wiring runs need to be kept short and tidy.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated GX system is the same platform found in Victron's standalone Cerbo GX. It provides access to the VRM online portal for remote monitoring, supports two-way communication with compatible lithium BMS units, and allows configuration via the built-in display or remotely. For installers already working within the Victron ecosystem, this removes the need to source, mount and configure a separate GX device, which reduces both cost and commissioning time.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist allows the unit to draw from both AC input and the battery simultaneously when loads exceed what the AC source can supply alone. This is particularly useful when the system is connected to a small generator, where running a large load would otherwise overload the generator. The 70A charger ensures the battery bank can be recharged efficiently from AC when solar input is insufficient.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP482507010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e5000VA \/ 4000W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMPPT Charge Controller Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum PV Open-Circuit Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGX Device\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e38.8 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076049333\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential home storage systems with 48V lithium or lead-acid battery banks.\u003c\/li\u003e\n  \u003cli\u003eOff-grid cabins, rural properties and agricultural buildings where grid connection is unavailable or uneconomical.\u003c\/li\u003e\n  \u003cli\u003eSelf-consumption solar installations where excess PV generation is stored and used to reduce grid import.\u003c\/li\u003e\n  \u003cli\u003eGenerator-backed off-grid systems where PowerAssist is needed to handle peak loads beyond the generator's rated output.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications requiring a high-capacity, integrated 48V inverter charger with solar input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron EasySolar-II 48\/5000\/70-50 MPPT 250\/100 GX unit (wall-mount enclosure)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit must be installed by a qualified electrician or MCS-accredited installer. At 38.8 kg, two-person handling is required for safe wall mounting. The 48V DC battery connections and high-current MPPT inputs must be correctly fused and cabled to the manufacturer's specifications. For any grid-connected application in the UK, confirm compliance requirements with your DNO and ensure the installation meets G98 or G99 regulations as applicable. Lithium battery integration requires a compatible BMS with the appropriate communication interface. Do not connect to the AC grid without confirming the correct relay and protection settings via the GX interface.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555475235,"sku":"PMP482507010","price":1698.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-easysolar-ii-48500070-50-mppt-250100-gx-pmp482507010-507381.webp?v=1789114946"},{"product_id":"victron-energymeter-et112-single-phase-100a","title":"Victron EnergyMeter ET112 -1 phase-max 100A*Available until stock 0* - REL300100000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy EnergyMeter ET112 Single Phase 100A — REL300100000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron EnergyMeter ET112 is a single-phase energy meter designed to measure AC energy flow at up to 100A. It integrates directly with Victron GX devices to provide real-time monitoring of grid consumption, solar production or generator output. This product is available until current stock is exhausted and will not be restocked.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-phase AC energy measurement with a maximum current rating of 100A.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron GX devices (Cerbo GX, Color Control GX, Venus GX) for system-level monitoring.\u003c\/li\u003e\n  \u003cli\u003eMeasures bidirectional energy flow, making it suitable for grid import\/export monitoring as well as PV production metering.\u003c\/li\u003e\n  \u003cli\u003eCommunicates via RS-485 Modbus, connecting directly to the VE.Can or USB port on GX devices using a suitable interface.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.15 kg, designed for DIN rail mounting inside a consumer unit or distribution board.\u003c\/li\u003e\n  \u003cli\u003eDisplays real-time power, voltage, current and cumulative energy (kWh) data accessible through the Victron GX interface and VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ET112 is a single-phase variant in Victron's ET energy meter range. It connects to a GX device over RS-485 Modbus using a USB to RS-485 interface, and once configured it reports live power data to the GX device. This allows the GX device to make intelligent decisions about energy routing, such as adjusting inverter\/charger output based on actual grid import or export figures.\u003c\/p\u003e\n\n\u003cp\u003eIn a typical ESS (Energy Storage System) installation, the ET112 is placed at the grid connection point so the system can measure what is being drawn from or exported to the grid. It can also be used to monitor a PV inverter that is not natively compatible with Victron communication protocols. The 100A rating covers the majority of single-phase residential and light commercial connections in the UK.\u003c\/p\u003e\n\n\u003cp\u003eNote: this product is listed as available until stock reaches zero. It is a discontinued line and will not be replenished once sold out. Buyers should confirm availability before ordering.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eREL300100000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhase configuration\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMaximum current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e100A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication protocol\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRS-485 Modbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDIN rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.15 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076039686\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAvailability\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDiscontinued — available until stock is exhausted\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid import\/export monitoring in Victron ESS installations.\u003c\/li\u003e\n  \u003cli\u003ePV production metering for non-Victron solar inverters connected to a GX device.\u003c\/li\u003e\n  \u003cli\u003eGenerator output monitoring in off-grid and hybrid systems.\u003c\/li\u003e\n  \u003cli\u003eSingle-phase residential and light commercial energy monitoring via the VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron EnergyMeter ET112 single-phase energy meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe ET112 must be installed by a qualified electrician. It is connected in-line with the AC supply at the measurement point and wired into the distribution board. Communication with the GX device requires a USB to RS-485 interface (not included). Ensure the GX device firmware is up to date to guarantee compatibility. As this is a discontinued product, verify stock availability before specifying it in a new installation design.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555508003,"sku":"REL300100000","price":196.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-energy-meter-et112-1-phase-max-100a-rel300100000-625239.jpg?v=1789115713"},{"product_id":"victron-mega-fuse-holder-cip000100001","title":"Victron Fuse holder for MEGA-fuse - CIP000100001","description":"\u003ch1 style=\"color: #f87c24;\"\u003eFuse Holder for MEGA-Fuse — CIP000100001\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy MEGA-fuse holder is a dedicated single-fuse housing designed to accept standard MEGA-format fuses in 12V, 24V and 48V DC systems. It is used wherever a high-current DC circuit requires a secure, accessible fuse point, including battery banks, inverter connections and busbar protection.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccepts standard MEGA-format fuses, compatible with the full Victron MEGA-fuse range.\u003c\/li\u003e\n  \u003cli\u003eDesigned for high-current DC applications including inverter and battery protection circuits.\u003c\/li\u003e\n  \u003cli\u003eCompact housing keeps the fuse accessible for inspection and replacement without disturbing the wider installation.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use across 12V, 24V and 48V DC system voltages.\u003c\/li\u003e\n  \u003cli\u003eLightweight at 0.11 kg, making it straightforward to mount in confined enclosures or battery compartments.\u003c\/li\u003e\n  \u003cli\u003eSold individually, allowing installers to specify exactly the number of fuse points required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\n\u003cp\u003eMEGA-fuses are a widely used format in automotive and marine DC protection, rated for high continuous currents. This holder provides the correct mechanical and electrical interface for those fuses, ensuring a low-resistance, vibration-resistant connection at the fuse terminals. Using the correct holder matters: an undersized or poorly rated holder introduces resistance and heat at the fuse point, which can cause nuisance tripping or damage to the fuse before a genuine fault occurs.\u003c\/p\u003e\n\n\u003cp\u003eThis holder is the standard Victron-supplied housing for MEGA-fuses used throughout their inverter, charger and battery system installations. It is a straightforward component, but selecting the right holder for the fuse format is an important step in any DC protection design. The holder is sold without a fuse; the appropriate MEGA-fuse rating must be selected separately based on the circuit's continuous current and cable sizing.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: CIP000100001\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076021704\u003c\/li\u003e\n  \u003cli\u003eCompatible fuse format: MEGA-fuse\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.11 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInverter DC input protection in off-grid and battery backup systems.\u003c\/li\u003e\n  \u003cli\u003eBattery bank fusing in 12V, 24V and 48V installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome DC distribution boards.\u003c\/li\u003e\n  \u003cli\u003eBusbar and cable protection in high-current DC circuits.\u003c\/li\u003e\n  \u003cli\u003eReplacement or additional fuse points in existing Victron system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x MEGA-fuse holder (fuse not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis holder should be installed as close to the positive battery terminal as practically possible to minimise unprotected cable length. Ensure the fuse rating is selected in accordance with the cable cross-section and the maximum continuous current of the connected equipment. DC wiring in battery and inverter systems carries high fault currents; installation should be carried out by a qualified electrician or experienced installer familiar with DC protection requirements.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555540771,"sku":"CIP000100001","price":9.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-fuse-holder-for-mega-fuse-cip000100001-568357.jpg?v=1789116094"},{"product_id":"victron-easysolar-ii-24-3000-70-mppt-250-70-gx","title":"Victron EasySolar-II 24\/3000\/70-32 MPPT 250\/70 GX - PMP242307010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron EasySolar-II 24\/3000\/70-32 MPPT 250\/70 GX\u003c\/h1\u003e\n\n\u003cp\u003eThe EasySolar-II GX is an all-in-one inverter charger for 24V off-grid and self-consumption systems. It combines a MultiPlus inverter charger, MPPT solar charge controller and GX monitoring device in a single wall-mounted unit. Designed for professional installers building residential or light commercial off-grid and backup power systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA inverter with 70A battery charger built in, rated for 24V battery banks\u003c\/li\u003e\n  \u003cli\u003eMPPT 250\/70 solar charge controller handles up to 250V open-circuit PV voltage and 70A charge current\u003c\/li\u003e\n  \u003cli\u003eIntegrated GX device provides onboard monitoring, VRM portal connectivity and DVCC support\u003c\/li\u003e\n  \u003cli\u003e32A AC input current limit for shore power or generator connection\u003c\/li\u003e\n  \u003cli\u003ePowerAssist function allows the unit to supplement AC input with inverter power, preventing overload of a limited supply\u003c\/li\u003e\n  \u003cli\u003eSingle enclosure design reduces wiring complexity and installation time compared to separate components\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus, VE.Direct and VE.Can ecosystem for full system integration\u003c\/li\u003e\n  \u003cli\u003eSKU: PMP242307010 | GTIN: 8719076049265 | Weight: 25.4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe EasySolar-II GX integrates three core system components into one enclosure: the MultiPlus inverter charger, an MPPT solar charge controller and a GX monitoring controller. For a 24V system, the 3000VA continuous output covers most residential loads, and the 70A MPPT handles PV arrays up to 250V Voc. The GX device runs Venus OS, giving installers access to the VRM online portal, local touchscreen display support and full DVCC (Distributed Voltage and Current Control) for managed battery systems.\u003c\/p\u003e\n\n\u003cp\u003eThe 70A battery charger uses an adaptive four-stage charging algorithm and supports a wide range of battery chemistries including lead-acid, AGM, gel and lithium. The 32A AC input accepts shore power or a generator, and PowerAssist prevents the AC source from being overloaded by supplementing it with inverter output when loads spike. This makes the unit well suited to sites with a limited generator or restricted grid connection.\u003c\/p\u003e\n\n\u003cp\u003eBecause the MPPT, inverter and GX controller share a single enclosure, there is no need for separate VE.Direct or VE.Bus cabling between those components. This simplifies commissioning and reduces potential points of failure. The unit still connects to external Victron devices via VE.Bus, VE.Direct and VE.Can ports, so it integrates fully into larger Victron systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP242307010\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e24V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Limit\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMPPT Model\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSmartSolar MPPT 250\/70\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMax PV Open-Circuit Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e250V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eMax MPPT Charge Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e70A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated GX Device\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (Venus OS)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e25.4 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076049265\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential systems with solar PV and battery storage\u003c\/li\u003e\n  \u003cli\u003eBackup power installations where generator or limited grid supply is the AC input\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications requiring a 24V all-in-one inverter charger with solar\u003c\/li\u003e\n  \u003cli\u003eSelf-consumption and home storage systems on a 24V battery bank\u003c\/li\u003e\n  \u003cli\u003eRemote site power where a single compact unit is preferred over multiple components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEasySolar-II 24\/3000\/70-32 MPPT 250\/70 GX unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out by a qualified electrician or accredited installer. The unit connects to 24V battery banks and accepts AC input from shore power or a generator. For any grid-connected application in the UK, ensure compliance with G98 or G99 requirements as applicable. Battery connections at this current rating involve significant fault energy; appropriate fusing and cable sizing is essential. Commissioning via the VRM portal and Venus OS is recommended to verify system configuration before handover.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555573539,"sku":"PMP242307010","price":1087.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-easysolar-ii-24300070-32-mppt-25070-gx-pmp242307010-653706.jpg?v=1789114863"},{"product_id":"victron-gx-touch-70","title":"Victron GX Touch 70 - BPP900455070","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron GX Touch 70\u003c\/h1\u003e\n\n\u003cp\u003eThe GX Touch 70 is a 7-inch touchscreen display for Victron GX devices, giving installers and system owners a clear, real-time view of system status without requiring a phone, tablet or laptop. It is designed for permanent panel or wall mounting in off-grid, marine and backup power installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e7-inch colour touchscreen with a clean, responsive interface for monitoring Victron GX systems.\u003c\/li\u003e\n  \u003cli\u003eDisplays live data including battery state of charge, solar yield, load consumption and AC input status.\u003c\/li\u003e\n  \u003cli\u003eConnects directly to compatible GX devices via a single cable, with no additional power supply required.\u003c\/li\u003e\n  \u003cli\u003eSupports on-screen control of connected Victron equipment, including switching inverters and setting charge modes.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.44 kg, suitable for flush or surface mounting in control panels and enclosures.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the Cerbo GX and other Victron GX platform devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GX Touch 70 connects to a Victron GX device (such as the Cerbo GX) and provides a dedicated local display for system monitoring and basic control. It draws power and data through a single cable connection to the GX device, keeping installation straightforward and avoiding the need for a separate power feed to the screen.\u003c\/p\u003e\n\n\u003cp\u003eThe 7-inch display shows the same overview pages available in the VRM portal and the GX device menu, including battery status, PV production, AC loads and grid or generator input. Installers can also navigate device settings and switch equipment states directly from the screen, which is useful during commissioning and for end users who prefer a fixed local display over a mobile app.\u003c\/p\u003e\n\n\u003cp\u003eThe screen is intended for indoor use and is well suited to control room panels, switchboard enclosures and marine helm stations where a permanent, always-on display is preferred. It does not replace the VRM portal for remote monitoring but complements it as a local interface.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPP900455070\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076054344\u003c\/li\u003e\n  \u003cli\u003eScreen size: 7 inches\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.44 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Victron GX platform devices (e.g. Cerbo GX)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePermanent local display for off-grid solar and battery systems using Victron GX devices.\u003c\/li\u003e\n  \u003cli\u003eControl panel integration in residential, commercial and industrial backup power installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and motorhome installations where a fixed helm or dashboard display is required.\u003c\/li\u003e\n  \u003cli\u003eCommissioning and diagnostics during installation, providing on-site system visibility without a laptop.\u003c\/li\u003e\n  \u003cli\u003eEnd-user facing displays in managed energy systems where remote access via VRM is also in use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGX Touch 70 touchscreen display unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe GX Touch 70 must be connected to a compatible Victron GX device. It is not a standalone unit and will not function without a GX device present in the system. Connection is made via the dedicated display port on the GX device. Installation should be carried out by a qualified electrician or accredited installer familiar with Victron system architecture. Ensure the mounting location is protected from moisture and direct exposure to the elements unless the enclosure provides adequate ingress protection.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555606307,"sku":"BPP900455070","price":293.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-gx-touch-70-bpp900455070-653358.jpg?v=1789115626"},{"product_id":"victron-lifepo4-12v-200ah-smart-battery","title":"Victron LiFePO4 Battery 12,8V\/200Ah Smart - BAT512120610","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron LiFePO4 Battery 12.8V 200Ah Smart — BAT512120610\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron LiFePO4 Battery 12.8V 200Ah Smart is a lithium iron phosphate drop-in battery designed for professional solar, off-grid, marine and vehicle applications. With 200Ah of usable capacity at 12.8V nominal voltage, it delivers significantly more usable energy than an equivalent lead-acid battery. The integrated Bluetooth module allows direct monitoring and configuration via the Victron Connect app.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e12.8V nominal voltage with 200Ah capacity, giving 2.56kWh of stored energy per unit.\u003c\/li\u003e\n  \u003cli\u003eLithium iron phosphate (LiFePO4) chemistry offers a stable, thermally safe cell compared to other lithium chemistries.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Bluetooth with Victron Connect app support for real-time state of charge monitoring, voltage, current and temperature data.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Battery Management System (BMS) provides cell balancing, over-charge, over-discharge, short circuit and over-temperature protection.\u003c\/li\u003e\n  \u003cli\u003eWeighs 19.5kg, substantially lighter than a comparable lead-acid battery of the same capacity.\u003c\/li\u003e\n  \u003cli\u003eDesigned for series and parallel connection to increase voltage or capacity in larger battery banks.\u003c\/li\u003e\n  \u003cli\u003eSKU: BAT512120610 | GTIN: 8719076045526\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eLiFePO4 chemistry is the preferred choice for professional installations where cycle life, safety and weight matter. Unlike AGM or gel lead-acid batteries, a LiFePO4 cell does not suffer from sulphation, and the usable depth of discharge is typically 80 to 100 percent of rated capacity rather than the 50 percent practical limit of lead-acid. For a 200Ah battery, this means a real-world usable capacity of 160 to 200Ah rather than approximately 100Ah from an equivalent lead-acid unit.\u003c\/p\u003e\n\u003cp\u003eThe Smart designation refers to the onboard Bluetooth interface. Using the Victron Connect app on iOS or Android, an installer or end user can read live battery data, review historical logs and configure protection parameters without physical wiring to a display or shunt. This is particularly useful during commissioning and for remote diagnostics on marine or vehicle installations where physical access to the battery is restricted.\u003c\/p\u003e\n\u003cp\u003eThe internal BMS handles cell-level protection autonomously. It communicates with compatible Victron chargers and inverter-chargers via the VE.Bus or VE.Direct ecosystem, enabling coordinated charge management across the system. When connecting multiple units in series or parallel, Victron's published guidelines for battery bank configuration should be followed to ensure balanced charging and correct BMS operation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBAT512120610\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12.8V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCapacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e200Ah\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eEnergy Content\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2.56kWh\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eChemistry\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLithium Iron Phosphate (LiFePO4)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes (Victron Connect app compatible)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBuilt-in BMS\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e19.5kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076045526\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid solar storage systems requiring high cycle life and reliable depth of discharge.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat house battery banks where weight reduction is a priority.\u003c\/li\u003e\n  \u003cli\u003eMotorhome, campervan and vehicle leisure battery installations.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for telecoms, security and critical equipment.\u003c\/li\u003e\n  \u003cli\u003eExpanding existing Victron 12V battery banks by connecting units in parallel.\u003c\/li\u003e\n  \u003cli\u003eMobile and portable power stations requiring a lightweight, high-capacity 12V source.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron LiFePO4 Battery 12.8V 200Ah Smart (BAT512120610)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis battery should be installed by a qualified electrician or experienced system integrator familiar with lithium battery systems. The internal BMS provides protection at the cell level, but correct fusing, cabling and charge source configuration remain the installer's responsibility. Ensure any connected charger, solar charge controller or inverter-charger is set to a lithium charge profile compatible with 12.8V LiFePO4 chemistry. When building multi-battery banks, follow Victron's series and parallel connection guidelines to maintain balanced operation. This product is not suitable for use with chargers configured for lead-acid profiles without reconfiguration.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555639075,"sku":"BAT512120610","price":962.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-lifepo4-battery-128v200ah-smart-bat512120610-448063.jpg?v=1789115183"},{"product_id":"victron-gx-touch-50-display","title":"Victron GX Touch 50 - BPP900455050","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron GX Touch 50 Touchscreen Display — BPP900455050\u003c\/h1\u003e\n\n\u003cp\u003eThe GX Touch 50 is a 5-inch touchscreen display designed for use with Victron GX devices, including the Cerbo GX and Venus GX. It gives installers and system operators a clear, real-time view of system status, energy flows and device data without requiring a phone, tablet or laptop on site.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e5-inch capacitive touchscreen with a clean graphical interface for monitoring system status at a glance.\u003c\/li\u003e\n  \u003cli\u003eConnects directly to compatible Victron GX devices via a dedicated display port, requiring no additional wiring or power supply.\u003c\/li\u003e\n  \u003cli\u003eDisplays live data including battery state of charge, solar yield, AC loads, grid status and generator input.\u003c\/li\u003e\n  \u003cli\u003eSupports touch-based navigation through the GX device menu, allowing on-site configuration and adjustments without remote access.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.37 kg, suitable for panel mounting in a variety of enclosures and installations.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Cerbo GX and other Victron GX devices that include a dedicated GX Touch port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GX Touch 50 connects to the GX Touch port on compatible Victron GX devices and draws both power and data through a single cable. There is no separate power connection required, which simplifies installation and reduces wiring in the enclosure. The display mirrors the interface available through VRM or the built-in web interface, giving on-site operators the same information they would see remotely.\u003c\/p\u003e\n\n\u003cp\u003eFor off-grid cabins, marine installations, vehicle conversions and commercial energy storage systems, having a local display is often a practical requirement. The GX Touch 50 provides that without adding complexity. It is not a standalone monitoring device and requires a compatible GX unit to function. Installers should confirm compatibility with the specific GX device before ordering.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: BPP900455050\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076048770\u003c\/li\u003e\n  \u003cli\u003eScreen size: 5 inches\u003c\/li\u003e\n  \u003cli\u003eTouch type: Capacitive\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eCompatible with: Cerbo GX and other Victron GX devices with a dedicated GX Touch port\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLocal monitoring display for off-grid solar and battery storage systems.\u003c\/li\u003e\n  \u003cli\u003eOn-site status panel in commercial or industrial energy storage installations.\u003c\/li\u003e\n  \u003cli\u003eMarine and narrowboat electrical system monitoring.\u003c\/li\u003e\n  \u003cli\u003eVehicle and motorhome power system displays.\u003c\/li\u003e\n  \u003cli\u003eWall or panel-mounted display in residential solar installations where remote monitoring alone is insufficient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x GX Touch 50 touchscreen display unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe GX Touch 50 must be connected to a compatible Victron GX device with a dedicated GX Touch port. It does not operate as a standalone unit. Installation into a live electrical enclosure should be carried out by a qualified electrician or experienced installer familiar with Victron GX systems. For grid-connected installations, ensure the wider system meets G98 or G99 requirements as applicable.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555671843,"sku":"BPP900455050","price":231.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-gx-touch-50-bpp900450100-955299.jpg?v=1789115560"},{"product_id":"victron-inverter-rs-48-6000-230v-smart","title":"Victron Inverter RS 48\/6000 230V Smart - PIN482600000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter RS 48\/6000 230V Smart — PIN482600000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter RS 48\/6000 is a 6000VA pure sine wave inverter designed for 48V battery systems with 230V AC output. It is aimed at off-grid installations, backup power systems and professional solar applications where high continuous power output and smart monitoring are required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6000VA continuous output power from a 48V DC battery bank to 230V AC single phase.\u003c\/li\u003e\n  \u003cli\u003ePure sine wave output suitable for sensitive loads including motors, compressors and electronics.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Bluetooth via VictronConnect for wireless configuration, monitoring and firmware updates without additional hardware.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed PowerControl and PowerAssist functions allow the inverter to supplement an AC source rather than overload it.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range accommodates varying battery states across lead-acid and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eComprehensive protection: over-temperature, overload, short circuit and low battery voltage shutdown.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron's GX device ecosystem for full system integration and remote monitoring via VRM portal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe RS 48\/6000 sits at the higher end of Victron's inverter-only range, delivering 6000VA from a 48V battery bus. At this power level, the unit is suited to installations where substantial AC loads must be run continuously from stored energy, such as off-grid homes, remote commercial sites or large backup systems. The 48V battery voltage is the standard choice at this power level because it keeps DC cable currents manageable compared to lower voltage alternatives.\u003c\/p\u003e\n\n\u003cp\u003eThe \"Smart\" designation refers to the integrated Bluetooth module, which enables direct communication with the VictronConnect app on iOS and Android. Installers can configure protection thresholds, monitor real-time performance and update firmware without physical access to the unit. For larger system installations, connecting a Victron GX device (such as a Cerbo GX) extends monitoring and control to the VRM online portal, enabling remote oversight of the full system.\u003c\/p\u003e\n\n\u003cp\u003eThe inverter supports both lead-acid and lithium battery banks. Battery type and voltage thresholds are configurable through VictronConnect, so the unit can be matched precisely to the battery chemistry in use. The RS series uses a high-frequency topology, which contributes to its relatively compact form factor and weight of 11 kg at this power rating.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN482600000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Frequency\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eOutput Waveform\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePure sine wave\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhase\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSingle phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBluetooth (VictronConnect)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e11 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076046059\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential systems requiring high continuous AC output from a 48V battery bank.\u003c\/li\u003e\n  \u003cli\u003eRemote commercial or agricultural sites running substantial AC loads without grid connection.\u003c\/li\u003e\n  \u003cli\u003eLarge backup power installations where mains failure must be covered by stored battery energy.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications with 48V DC systems and high AC load requirements.\u003c\/li\u003e\n  \u003cli\u003eHybrid systems integrated with Victron GX devices for full MPPT, battery and load management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter RS 48\/6000 230V Smart unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation of this inverter should be carried out by a qualified electrician or accredited installer with experience in DC battery systems and off-grid AC wiring. At 6000VA from a 48V battery bank, DC cable sizing and fusing are critical: use appropriately rated DC cables and a suitably rated fuse or breaker as close to the battery as practicable. The unit is not a grid-tied inverter and does not hold G98 or G99 approval for export to the UK grid. Ensure the battery bank chemistry and voltage thresholds are correctly configured in VictronConnect before commissioning. For lithium battery systems, verify BMS compatibility before connecting.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555704611,"sku":"PIN482600000","price":1153.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-inverter-rs-486000-230v-smart-solar-charger-pin482600000-548519.jpg?v=1789114887"},{"product_id":"victron-inverter-rs-48-6000-230v-smart-solar","title":"Victron Inverter RS 48\/6000 230V Smart Solar - PIN482601000","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Inverter RS 48\/6000 230V Smart Solar — PIN482601000\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Inverter RS 48\/6000 is a 6000VA inverter with an integrated MPPT solar charge controller, designed for 48V off-grid and hybrid battery systems. It is aimed at professional installers working on residential, commercial and industrial off-grid projects where a single, capable unit is preferred over separate components.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e6000VA continuous inverter output at 230V AC, suitable for demanding off-grid loads.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Smart Solar MPPT charge controller for direct PV array connection without a separate unit.\u003c\/li\u003e\n  \u003cli\u003eDesigned for 48V battery banks, compatible with lead-acid and lithium battery chemistries.\u003c\/li\u003e\n  \u003cli\u003eVE.Direct and Bluetooth connectivity for monitoring and configuration via the Victron Connect app.\u003c\/li\u003e\n  \u003cli\u003eCompact, wall-mounted form factor weighing 12 kg, reducing installation space requirements.\u003c\/li\u003e\n  \u003cli\u003e230V AC output suitable for standard single-phase European and UK electrical loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Inverter RS 48\/6000 combines a high-capacity inverter with an integrated MPPT solar charge controller in a single enclosure. This reduces wiring complexity and cabinet space compared to installing separate inverter and charge controller units. The 48V DC input voltage is well suited to larger battery banks where lower current draw at a given power level reduces cable sizing and heat losses.\u003c\/p\u003e\n\n\u003cp\u003eThe Smart Solar designation indicates the unit includes Victron's MPPT algorithm, which tracks the maximum power point of the connected PV array to maximise energy harvest across varying irradiance and temperature conditions. Connectivity via VE.Direct and Bluetooth allows integration with Victron's GX monitoring ecosystem and remote configuration through VictronConnect, which is relevant for installations requiring ongoing monitoring or commissioning from a mobile device.\u003c\/p\u003e\n\n\u003cp\u003eAt 12 kg, the unit is manageable for a single installer during wall mounting, though the 6000VA output class means it will typically be paired with substantial battery and PV capacity. Correct fusing, cable sizing and battery compatibility should be confirmed against Victron's published installation documentation before commissioning.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePIN482601000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e6000VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eIntegrated Charge Controller\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSmart Solar MPPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eConnectivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Direct, Bluetooth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076048176\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid residential systems with 48V lithium or lead-acid battery banks.\u003c\/li\u003e\n  \u003cli\u003eRemote commercial or agricultural installations requiring reliable AC power from solar.\u003c\/li\u003e\n  \u003cli\u003eMarine and vehicle applications where a 48V DC bus and 230V AC output are required.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems where solar charging and inverter functionality must operate independently of the grid.\u003c\/li\u003e\n  \u003cli\u003eRetrofit installations replacing separate inverter and charge controller units to reduce enclosure space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVictron Inverter RS 48\/6000 230V Smart Solar unit (PIN482601000)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThis unit operates at 48V DC and 230V AC and must be installed by a qualified electrician or MCS-accredited installer. Battery connections, PV array wiring, fusing and earthing must comply with BS 7671 and any applicable local regulations. For systems connected to or operating alongside the grid, G98 or G99 notification and compliance requirements must be assessed with your DNO. Lithium battery integration may require additional BMS communication configuration within the Victron ecosystem.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555737379,"sku":"PIN482601000","price":1409.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-inverter-rs-486000-230v-smart-solar-pin482601000-443328.jpg?v=1789114572"},{"product_id":"lynx-shunt-vecan-lyn040102100","title":"Victron Lynx Shunt VE.Can (M8) - LYN040102100 *If 0, order LYN040102110*","description":"\u003ch1\u003eLynx Shunt VE.Can (M8) – Precise Battery Monitoring for DC Systems\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eLynx Shunt VE.Can (M8)\u003c\/strong\u003e is an integral part of Victron Energy's advanced Lynx distribution system, designed to streamline DC connections, battery monitoring, and fusing for both small and large battery systems. This shunt is equipped with M8 connections and works seamlessly with a \u003cem\u003eGX device\u003c\/em\u003e to provide accurate and real-time battery information, helping to ensure your system operates efficiently and safely.\u003c\/p\u003e\n\u003ch2\u003eKey Features of the Lynx Shunt VE.Can (M8)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eComes with an integrated \u003cstrong\u003epositive and negative busbar\u003c\/strong\u003e for effective current flow management.\u003c\/li\u003e\n\u003cli\u003eFeatures a battery monitor and space for a \u003cstrong\u003emain system fuse\u003c\/strong\u003e, providing protection against potential overloads and faults.\u003c\/li\u003e\n\u003cli\u003eSupports \u003cem\u003eVE.Can communication\u003c\/em\u003e for simple integration with a \u003cstrong\u003eGX device\u003c\/strong\u003e, enabling you to monitor battery performance via the VRM portal or a compatible display.\u003c\/li\u003e\n\u003cli\u003eEquipped with two RJ45 VE.Can terminators, ensuring a reliable connection to your battery system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEfficient Battery Monitoring and Protection\u003c\/h2\u003e\n\u003cp\u003eThe Lynx Shunt VE.Can (M8) not only monitors your battery’s health but also tracks charge and discharge levels with precision. It is designed to handle a continuous current rating of up to \u003cstrong\u003e1000 Amps\u003c\/strong\u003e, making it suitable for a wide range of off-grid and on-grid power systems. For improved system flexibility, the M8 model is equipped with support for \u003cstrong\u003eCNN fuses\u003c\/strong\u003e, which can be purchased separately based on system requirements.\u003c\/p\u003e\n\u003ch2\u003eSeamless Integration into Lynx Distribution Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLynx Shunt VE.Can\u003c\/strong\u003e is part of the modular \u003cstrong\u003eLynx Distribution System\u003c\/strong\u003e, which also includes the Lynx Power In and Lynx Distributor modules. These components work together to form a comprehensive DC distribution system, simplifying the connection of batteries, inverters, and other equipment.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eLynx Shunt VE.Can (M8)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9 - 70 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported System Voltages\u003c\/td\u003e\n\u003ctd\u003e12, 24, or 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e1000 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA @ 12 V, 33 mA @ 24 V, 20 mA @ 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Material\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusbar Dimensions\u003c\/td\u003e\n\u003ctd\u003e8 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Dimensions\u003c\/td\u003e\n\u003ctd\u003e190 x 180 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eMax. 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eLooking for More Power? Check Out the New Lynx Shunt VE.Can (M10)\u003c\/h2\u003e\n\u003cp\u003eWe are excited to introduce the new \u003ca href=\"victron-lynx-shunt-ve-can-m10\"\u003eLynx Shunt VE.Can (M10), model LYN040102110\u003c\/a\u003e, which brings significant improvements over the previous M8 version.\u003c\/p\u003e\n\u003cp\u003eAs part of our commitment to enhancing the Lynx product range, this upgrade features M10 connections, offering a stronger and more durable connection compared to the M8 standard.\u003c\/p\u003e\n\u003cp\u003eAdditionally, this version includes a small busbar, ideal for systems requiring a higher-rated fuse than the standard 325A CNN fuse. This allows for the main fuse to be located externally, providing greater flexibility for larger systems. The Lynx Shunt M10 now supports external fuses, including CNN fuses from 35A to 800A, as well as ANL fuses.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555770147,"sku":"LYN040102100","price":346.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-lynx-shunt-vecan-m8-lyn040102100-990360.webp?v=1789114651"},{"product_id":"victron-energy-meter-vm-3p75ct","title":"Victron Energy Meter VM-3P75CT - REL200300100","description":"\u003ch1 style=\"color: #f87c24;\"\u003eEnergy Meter VM-3P75CT — REL200300100\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy Meter VM-3P75CT is a three-phase energy monitoring device designed for use with Victron GX systems. It measures import and export energy across all three phases, giving installers and system operators accurate, real-time visibility of grid consumption and feed-in. Suitable for residential, commercial and off-grid hybrid installations where precise energy accounting is required.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase energy metering with individual phase measurement for accurate grid monitoring.\u003c\/li\u003e\n  \u003cli\u003eIncludes 75A current transformers (CTs) for non-invasive current measurement without breaking the circuit.\u003c\/li\u003e\n  \u003cli\u003eIntegrates directly with Victron GX devices (Cerbo GX, Venus GX, CCGX) via RS485 connection.\u003c\/li\u003e\n  \u003cli\u003eMeasures both import and export energy, making it suitable for solar feed-in monitoring and grid interaction tracking.\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight at 0.25 kg, suitable for installation inside a consumer unit or distribution board enclosure.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VRM portal for remote monitoring and historical energy data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe VM-3P75CT connects to a Victron GX device over RS485 and reports real-time power, voltage, current and energy totals for each phase. This data feeds directly into the GX device's energy management logic, allowing the system to make informed decisions about battery charging, grid feed-in and load management. For installers commissioning three-phase hybrid or grid-tied systems, having accurate per-phase data is essential for correct system behaviour and regulatory compliance.\u003c\/p\u003e\n\n\u003cp\u003eThe included 75A split-core current transformers clip around existing conductors without requiring the circuit to be de-energised during installation of the CTs themselves. This simplifies retrofitting into existing switchgear. The meter communicates over a standard RS485 bus, and multiple meters can be used within a single GX system where the installation requires monitoring at more than one point, such as separately metering a generator input or a sub-distribution board.\u003c\/p\u003e\n\n\u003cp\u003eData from the VM-3P75CT is visible locally on any connected GX display and remotely through the Victron VRM portal. This makes it straightforward to track consumption patterns, verify solar yield against grid import, and produce energy reports for commercial or billing purposes.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eREL200300100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePhases\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCurrent Transformer Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e75A (split-core CTs included)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eRS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCompatible GX Devices\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCerbo GX, Venus GX, CCGX and other Victron GX products\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076059462\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGrid import and export monitoring in three-phase residential or commercial solar installations.\u003c\/li\u003e\n  \u003cli\u003eFeed-in metering for systems with battery storage and grid interaction, including ESS (Energy Storage System) configurations.\u003c\/li\u003e\n  \u003cli\u003eMonitoring generator input or sub-distribution boards as a secondary meter within a GX system.\u003c\/li\u003e\n  \u003cli\u003eRetrofit energy monitoring in existing three-phase switchgear without circuit interruption.\u003c\/li\u003e\n  \u003cli\u003eCommercial sites requiring per-phase energy data for billing, reporting or load balancing purposes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Victron Energy Meter VM-3P75CT (REL200300100)\u003c\/li\u003e\n  \u003cli\u003e3x 75A split-core current transformers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe VM-3P75CT must be installed by a qualified electrician. Work inside a live distribution board or consumer unit carries significant risk and must comply with BS 7671 (IET Wiring Regulations). The meter connects to a Victron GX device via RS485; ensure the correct RS485 to USB interface cable is available if your GX device does not have a dedicated RS485 port. For grid-connected systems operating under G98 or G99 conditions, confirm that the energy meter placement and system configuration meet DNO requirements. Do not exceed the 75A CT rating on any phase.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632555999523,"sku":"REL200300100","price":166.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-energy-meter-vm-3p75ct-rel200300100-242203.jpg?v=1789116275"},{"product_id":"victron-ev-charging-station","title":"Victron EV Charging station - EVC300400300","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron Energy EV Charging Station\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron Energy EV Charging Station is a single-phase electric vehicle charger designed for integration with Victron solar and battery systems. It is suited to residential and light commercial installations where solar self-consumption and smart charging control are priorities.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrates with Victron GX devices for solar-aware and grid-aware EV charging control.\u003c\/li\u003e\n  \u003cli\u003eSupports dynamic current adjustment, allowing charge rate to follow available solar or grid capacity.\u003c\/li\u003e\n  \u003cli\u003eCompatible with all Type 2 (IEC 62196) electric vehicles, the standard connector type across the UK and EU.\u003c\/li\u003e\n  \u003cli\u003eCompact wall-mount design with a unit weight of 3 kg, suitable for indoor and sheltered outdoor installation.\u003c\/li\u003e\n  \u003cli\u003eMonitored and controlled via the VictronConnect app and the Victron Remote Management (VRM) portal.\u003c\/li\u003e\n  \u003cli\u003eSKU: EVC300400300, GTIN: 8719076051305.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Victron EV Charging Station connects directly to the Victron ecosystem via a GX device (such as the Cerbo GX). This allows the charger to respond in real time to solar production and battery state, increasing or decreasing the charge current automatically. For installations with a solar array and battery bank, this means EV charging can be prioritised from surplus solar generation rather than drawing from the grid.\u003c\/p\u003e\n\n\u003cp\u003eDynamic current control is the practical advantage here. Rather than charging at a fixed rate, the station adjusts its output current based on rules configured through the GX device. This is particularly useful for sites with export limitations or where grid import costs are a concern. The charger communicates over a local network connection and is visible within the VRM portal alongside all other Victron system components.\u003c\/p\u003e\n\n\u003cp\u003eThe unit uses the Type 2 connector standard, which is mandatory for new EV charge points in the UK and across the EU. This ensures compatibility with the full range of current passenger and light commercial electric vehicles.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSKU: EVC300400300\u003c\/li\u003e\n  \u003cli\u003eGTIN: 8719076051305\u003c\/li\u003e\n  \u003cli\u003eWeight: 3 kg\u003c\/li\u003e\n  \u003cli\u003eConnector type: Type 2 (IEC 62196)\u003c\/li\u003e\n  \u003cli\u003eIntegration: Victron GX device required for smart charging features\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSolar self-consumption maximisation: charge an EV from surplus PV generation.\u003c\/li\u003e\n  \u003cli\u003eOff-grid and hybrid system sites where charge current must be managed against battery state.\u003c\/li\u003e\n  \u003cli\u003eResidential installations requiring remote monitoring and control via VRM.\u003c\/li\u003e\n  \u003cli\u003eLight commercial premises with existing Victron energy management infrastructure.\u003c\/li\u003e\n  \u003cli\u003eSites with grid export limitations where dynamic load control is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron Energy EV Charging Station (EVC300400300)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out by a qualified electrician. In the UK, EV charge point installation is subject to Part P of the Building Regulations and must be notified to the relevant building control authority. Connection to a Victron GX device is required to enable smart charging functionality. Ensure the supply circuit is correctly rated for the maximum charge current of the unit. Do not install in locations exposed to direct weather without appropriate enclosure protection.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632556065059,"sku":"EVC300400300","price":497.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/victron-ev-electric-vehicle-charging-station-74-kw-1-phase-or-22-kw-3-phase-evc300400300-873545.jpg?v=1789114590"},{"product_id":"victron-multiplus-ii-12-3000-120-32-230v","title":"Victron MultiPlus-II 12\/3000\/120-32 230V - PMP122305010","description":"\u003ch1 style=\"color: #f87c24;\"\u003eVictron MultiPlus-II 12\/3000\/120-32 230V Inverter Charger\u003c\/h1\u003e\n\n\u003cp\u003eThe Victron MultiPlus-II 12\/3000\/120-32 is a 3000VA inverter charger operating on a 12V battery bank with a 120A battery charger and 32A AC current limiter. It is designed for off-grid installations, marine and vehicle applications, and backup power systems where a single, integrated unit is needed to handle both inverting and charging duties.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3000VA continuous inverter output with a 12V DC input, suitable for moderate to heavy AC loads.\u003c\/li\u003e\n  \u003cli\u003e120A multi-stage battery charger with adaptive charge algorithm, compatible with a wide range of battery chemistries including lithium, AGM, gel and flooded lead-acid.\u003c\/li\u003e\n  \u003cli\u003e32A AC input current limiter, allowing the unit to supplement shore power or generator input with battery power when the source is limited.\u003c\/li\u003e\n  \u003cli\u003ePowerControl and PowerAssist functions prevent overloading of a limited AC source by drawing additional current from the battery bank as required.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in transfer switch with a typical switchover time of less than 20 milliseconds, maintaining continuity for most connected equipment.\u003c\/li\u003e\n  \u003cli\u003eTwo AC outputs: AC-out-1 remains live during a mains failure; AC-out-2 is disconnected when running on inverter, allowing non-critical loads to be shed automatically.\u003c\/li\u003e\n  \u003cli\u003eCompatible with Victron VE.Bus for system integration, remote monitoring via GX devices, and configuration through VEConfigure software.\u003c\/li\u003e\n  \u003cli\u003eSupports parallel and three-phase operation when multiple units are used together.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II combines a sine wave inverter, a multi-stage battery charger, and an automatic transfer switch in a single enclosure. The 120A charger output is substantial for a 12V unit, making it practical where fast battery recovery is a priority, such as after a generator run or when connected to shore power with limited availability. The adaptive charge algorithm adjusts charge parameters based on battery behaviour over time, which is particularly useful in installations where the battery bank is not always fully discharged before recharging.\u003c\/p\u003e\n\n\u003cp\u003ePowerAssist is one of the more practically useful features for installations with a constrained AC source. When the connected load exceeds what the shore power or generator can supply alone, the unit draws the deficit from the battery bank rather than tripping the source breaker. This is especially relevant on boats, in campervans, or in off-grid cabins where the generator or shore supply has a fixed current limit. The 32A input current limit on this model is configurable, giving the installer control over how much of the source capacity is reserved for charging versus load supply.\u003c\/p\u003e\n\n\u003cp\u003eThe dual AC output configuration adds practical load management without additional switching hardware. AC-out-1 is always live when the unit is operational, while AC-out-2 drops out when the inverter is running on battery alone. This allows non-essential loads such as water heaters or air conditioning to be wired to AC-out-2, reducing battery drain automatically without any manual intervention.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border: 2px solid #f87c24; border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f87c24; color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eSKU\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003ePMP122305010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eInverter Output Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e3000VA \/ 2400W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eDC Input Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e12V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eBattery Charger Output\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e120A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Input Current Limit\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e32A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Output Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e230V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eAC Outputs\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e2 (AC-out-1 always live; AC-out-2 disconnects on inverter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eTransfer Switch Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eLess than 20ms (typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eCommunication\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eVE.Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e20.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003eGTIN\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #f87c24; padding: 8px;\"\u003e8719076048916\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOff-grid cabins and remote properties requiring reliable AC power from a 12V battery bank.\u003c\/li\u003e\n  \u003cli\u003eMarine installations where shore power is supplemented by battery during peak demand.\u003c\/li\u003e\n  \u003cli\u003eMotorhomes and large campervans with significant AC load requirements.\u003c\/li\u003e\n  \u003cli\u003eBackup power systems for critical equipment where fast transfer and continuous AC-out-1 supply is required.\u003c\/li\u003e\n  \u003cli\u003eHybrid off-grid systems paired with solar charge controllers and a GX monitoring device.\u003c\/li\u003e\n  \u003cli\u003eParallel or three-phase configurations where multiple MultiPlus-II units are combined for higher output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Victron MultiPlus-II 12\/3000\/120-32 230V inverter charger unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #f87c24;\"\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eThe MultiPlus-II 12\/3000\/120-32 handles high DC currents at 12V and must be installed by a qualified electrician or accredited installer. Cable sizing, fusing and battery connections must be rated appropriately for the current involved. For any grid-connected or shore-power-connected installation in the UK, compliance with current wiring regulations (BS 7671) is required. Configuration via VEConfigure is recommended before commissioning to set battery type, charge parameters and AC input current limits correctly. For marine installations, follow applicable marine wiring standards. Do not attempt installation without appropriate electrical competency.\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47632556884259,"sku":"PMP122305010","price":965.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/files\/PMP122305010_Multiplus-II_12V_3kVA_120-32_230V_front.webp?v=1789114834"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/9001\/4243\/collections\/victron_products_c1c7e895-fbdd-4651-a3f6-87e1706a9727.jpg?v=1789123956","url":"https:\/\/voltaconsolar.eu\/collections\/victron-products.oembed?page=8","provider":"VoltaconSolar EU","version":"1.0","type":"link"}